Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-Finance OFFICE NO 3 CSC 5 1ST FLOOR GOLE MARKET ROHINI NORTH WEST DELHI DELHI 110085 UDYAM DL 06 0003676 | NORTH WEST DELHI | DELHI | 110085 | ₹10.6 L | L1 | Accepted-Finance ok |
| 2 | L2₹10.8 LAccepted-Finance | ₹10.8 L | L2 | Accepted-Finance ok |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | GENNEXT LAB TECHNOLOGIES PVT LTD L1 | CHANDRA ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.01 | Portable Turbidity Meter
Model: 2100Q
Technical Specification of Portable Turbidity Meter
Make: HACH/WTW/Merck/Thermo Fisher or any other DJB Approved make
Technical Specification of of Portable Turbidity Meter must have ratio turbidimetric determination using a primary nephelometric light scatter signal 90° to the transmitted light scatter signal meets EPA & ISO 7027 certified as follows:
Measurement Specifications:
Measurement Principal: Ratio turbidimetric determination using a primary
nephelometric light scatter signal 90° to the transmitted light scatter signal.
Measurement Range: 0 to 1000 NTU (FNU)
Accuracy: ±2% of reading plus stray light from 0 to 1000 NTU
Repeatability: ±1% of reading, or 0.01 NTU (FNU), whichever is greater
Resolution: 0.01 NTU (lowest range)
Compliance: EPA Method 180.1 & ISO 7027
Stray Light: less than 0.02 NTU
Signal Averaging: Selectable on/off
Detector: Silicon photovoltaic
Light Source: Tungsten filament lamp
Reading Modes (user selectable options): Normal (Push to Read),Signal Averaging, Rapidly Settling Turbidity
Rapidly Settling Turbidity (RST) Mode: for improved measurement of unstable & settling samples.
Dual Detector Optical System: for light fluctuation, compensates of color & stray light interference,
On-Screen assisted Calibration and Verification: to minimize operator error. All the core measurement information is on a single screen.
Data Logging Capacity: 500 records or better with date, time & calibration status
Mechanical & Operational Requirements
Power Supply: 4 AA alkaline batteries & AC Power with USB port
Operating Temperature: 0 to 50°C
Storage Temperature : -40 to 60°C
Instrument Enclosure Rating: IP67
Protection Class: Power Supply: Class II
Certification: CE certified
Sample Volume: 15 mL or better
Sample Cells : 60 x 25 mm round glass with screw cap
3. Accessories to be supplied:
carrying case with calibration standards in 1" sealed vials of 20, 100, 800 NTU), 6 sample glass round cells with screw-tops, instrument manual, silicone oil and oiling cloth
Warranty : The instrument shall be supplied with a minimum one year comprehensive warranty from the date of installation. | 4 | Nos. | 8,96,000 ₹10,57,280 | 9,12,000 ₹10,76,160 |
Tender Value
Refer Docs
EMD Value
₹21,300
Closing Date
20 Mar 2026, 3:00 pmClosed
CWA(WnS)II
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE CHIEF WATER ANALYST (WnS)- II HAIDERPUR WATER WORKS DELHI 110085
Procurement of Turbidity Meters for Quality Control Laboratories running under CWA(WnS)-II Division.
2026_DJB_288679_1
NIT No. 20(25-26)/CWA(WnS)II
Open Tender
Miscellaneous Goods
60 days
HAIDERPUR WATER WORKS
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Online sabpaisa portal Allahabad Bank
₹21,300
24 Mar 2026
13 Mar 2026
20 Mar 2026
13 Mar 2026
20 Mar 2026
13 Mar 2026
Select, Excess (+), Less (-)
Tender Inviting Authority: Chief Water Analyst (W&S)-II
Name of Work: Procurement of Turbidity Meters for Quality Control Laboratories running under CWA(W&S)-II Division.
NIT No.- 20 (2025-26) Item No. 01.
Sl. No. Item Description Item Code / Make Quantity Units Applicbale % of Basic Rate (on which Service Tax will be calculated) Applicbale % of Basic Rate(on which GST will be calculated) Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P GST in % Service Tax in % GST Amount in INR Service Amount in INR Total Unit Price in INR
1.01 Portable Turbidity Meter Model: 2100Q Technical Specification of Portable Turbidity Meter Make: HACH/WTW/Merck/Thermo Fisher or any other DJB Approved make Technical Specification of of Portable Turbidity Meter must have ratio turbidimetric determination using a primary nephelometric light scatter signal 90° to the transmitted light scatter signal meets EPA & ISO 7027 certified as follows: Measurement Specifications: Measurement Principal: Ratio turbidimetric determination using a primary nephelometric light scatter signal 90° to the transmitted light scatter signal. Measurement Range: 0 to 1000 NTU (FNU) Accuracy: ±2% of reading plus stray light from 0 to 1000 NTU Repeatability: ±1% of reading, or 0.01 NTU (FNU), whichever is greater Resolution: 0.01 NTU (lowest range) Compliance: EPA Method 180.1 & ISO 7027 Stray Light: less than 0.02 NTU Signal Averaging: Selectable on/off Detector: Silicon photovoltaic Light Source: Tungsten filament lamp Reading Modes (user selectable options): Normal (Push to Read),Signal Averaging, Rapidly Settling Turbidity Rapidly Settling Turbidity (RST) Mode: for improved measurement of unstable & settling samples. Dual Detector Optical System: for light fluctuation, compensates of color & stray light interference, On-Screen assisted Calibration and Verification: to minimize operator error. All the core measurement information is on a single screen. Data Logging Capacity: 500 records or better with date, time & calibration status Mechanical & Operational Requirements Power Supply: 4 AA alkaline batteries & AC Power with USB port Operating Temperature: 0 to 50°C Storage Temperature : -40 to 60°C Instrument Enclosure Rating: IP67 Protection Class: Power Supply: Class II Certification: CE certified Sample Volume: 15 mL or better Sample Cells : 60 x 25 mm round glass with screw cap 3. Accessories to be supplied: carrying case with calibration standards in 1" sealed vials of 20, 100, 800 NTU), 6 sample glass round cells with screw-tops, instrument manual, silicone oil and oiling cloth Warranty : The instrument shall be supplied with a minimum one year comprehensive warranty from the date of installation. item1 Nos. Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select %
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
NIT20doc.pdf
Tender Documents • 1.05 MB
BOQ_382882.xls
BOQ • 0.27 MB
corrigendumNIT20.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid