Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAdmitted-Finance MUNICIPALITY ROAD OPPOSITE DPL BHAT BUILDING KARAN NAGAR BATAMALOO SRINAGAR SRINAGAR JAMMU KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | L1 | Admitted-Finance | |
| 2 | L2₹55.1 L+₹5.4 L (11.0%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AL HASSAN ASSOCIATES L1 | M/S WATT ELECTRICAL CONTRACTS L2 |
|---|---|---|---|---|---|
| 1.00Augmentation of 33 KV Lines of STD Ganderbal to overcome LCP Constraints PDDSS2526100172 (Augmentation of 33KV Shadipora HMT line) | |||||
| 1.10 | Transportation,Installation, Testing and commissioning of 11 mtr ST. Poles (ST-410 SP56) (Poles to be lifted from Divisional Store Safapora) | 55 | Nos | 7,000 ₹3,85,000 | 5,786 ₹3,18,230 Lowest |
| 1.20 | Providing and Fixing of GI V cross-arm with top Bracket /GI Channel X-arm, including clamps and braces of Standard Sorts. | 2,035 | Kgs | 160 ₹3,25,600 | 121 ₹2,46,235 Lowest |
| 1.30 | Providing and Fixing 33 kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 165 | Nos | 700 ₹1,15,500 Lowest | 777 ₹1,28,205 |
| 1.40 | Providing and Fixing 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting | 48 | Nos | 1,500 ₹72,000 | 555 ₹26,640 Lowest |
| 1.50 | Supply, Laying , Testing and commissioning of 150 mm² ACSR conductor | 18.54 | Kms | 1,72,000 ₹31,88,880 Lowest | 2,31,331 ₹42,88,876.74 |
| 1.60 | Providing and Fixing PG Clamps for 150 mm² ACSR Conductor | 100 | No. | 700 ₹70,000 | 323 ₹32,300 Lowest |
| 1.70 | Providing and Fixing 33 kV Single Tension Fittings (6 bolt) suitable for 0.15 ACSR | 30 | No. | 700 ₹21,000 | 555 ₹16,650 Lowest |
| 1.80 | Supply ,Installation Testing and Commissioning of Galvanized Nuts and Bolts | 85 | kgs | 160 ₹13,600 | 121 ₹10,285 Lowest |
| 1.90 | Providing and Fixing Danger Plates with Clamps | 55 | Nos | 100 ₹5,500 Lowest | 555 ₹30,525 |
Tender Value
₹57.7 L
EMD Value
₹1.2 L
Closing Date
12 Feb 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER STD GANDERBAL
STD GBL DIV OFFICE
Augmentation of 33 KV Lines of STD Ganderbal to overcome LCP Constraints PDDSS2526100172 (Augmentation of 33KV Shadipora HMT line)
2026_PDD_301918_1
STDGBL e-NIT NO 31 OF 2025-26 DATED 31-01-26
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
BANDIPORA
REFER SBD
8 documents required · 8 mandatory
₹2,000
EXECUTIVE ENGINEER STD GBL
₹1.2 L
17 Feb 2026
31 Jan 2026
13 Feb 2026
31 Jan 2026
12 Feb 2026
2 Feb 2026
31 Jan 2026 - 2 Feb 2026
Augmentation of 33 KV Lines of STD Ganderbal to overcome LCP Constraints PDDSS2526100172 (Augmentation of 33KV Shadipora HMT line)
Transportation,Installation, Testing and commissioning of 11 mtr ST. Poles (ST-410 SP56) (Poles to be lifted from Divisional Store Safapora)
Providing and Fixing of GI V cross-arm with top Bracket /GI Channel X-arm, including clamps and braces of Standard Sorts.
Providing and Fixing 33 kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing and Fixing 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting
Supply, Laying , Testing and commissioning of 150 mm² ACSR conductor
Providing and Fixing PG Clamps for 150 mm² ACSR Conductor
Providing and Fixing 33 kV Single Tension Fittings (6 bolt) suitable for 0.15 ACSR
Supply ,Installation Testing and Commissioning of Galvanized Nuts and Bolts
Providing and Fixing Danger Plates with Clamps
Providing and Fixing Anti-Climbing Device with Clamps
Providing and Fixing Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip 25x3mm.
Providing and Painting of Aluminium paint on ST Poles as per REC standard
Providing & Laying of Cement bottoming 1:2:4 mix as per REC standards 0.66 cum/pole
Providing and Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2No..), anchor plate (300x300 x 8 mm), nut-bolts, 2 No. turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete (33kV)
Straightening of Tilted ST poles after opening of half pits and refilling after straightening along with Cement bottoming 1:2:4 mix.
Dismantelling of old existing ST / DW Pole along with transportation of red material upto Division Store.
Dismentalling of old existing 0.1 ACSR and returning of the same to Divisional Store Safapora
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
sbd31.pdf
Tender Documents • 1.49 MB
BOQ_979567.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .