Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC ADMITTED | |
| 2 | L2₹12.5 L+₹1.3 L (11.8%)Accepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L2 | Accepted-AOC ADMITTED |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
17 Mar 2021, 6:00 pmClosed
GE(A) Barmer
Military Engineer Services Garrison Engineer Army Jalipa Mil Stn Post box No 53 Barmer 344001
REPAIR AND REPLACEMENT OF ELECTRIC WIRING OF OLD VINTAGE SHELTERS ALONGWITH FITTING AND FIXTURES AT JALIPA MIL STN UNDER GE ARMY BARMER
2021_MES_425066_1
GE(A)/BMR-69 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE(A) Barmer
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹24,000
Yes
31 Mar 2021
24 Feb 2021
19 Mar 2021
24 Feb 2021
17 Mar 2021
3 Mar 2021
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and as directed.
Taking down un-serviceable main switches, bus bar chamber DB of any size and capacity including all fitting and fixture such as isolater MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and as directed.
Taking down unserviceable sub main wiring of copper/aluminium conductor,PVC insulated,unsheathed cable of any size with drawn through and including rigid PVC conduit or steel conduit or PVC casing & caping including cutting chases for conduit or steel conduit and making good disturbed surfaces complete all as specified and as directed.
All as per Sl item No.03 above but with out taking down steel conduit or PVC conduit or PCC casing & caping.
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor, nominal cross-sectional area is 1.5 sq mm , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including drawn through and including in PVC casing & caping with all fitting and accessories of casing caping complete fixed to wall/roof/floor etc, ISI marked with PVC terminal box , with suitable size cadmium plateed iron screws and washers for mounting of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.50 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/fan/ bell point controlled by one, one way switch complete all as specified and directed .
All as per serial item No 5.00 here-in-above but for One 5 Amps 3/5 pin socket outlet on same board with other switches.
All as per serial item No 5.00 here-in-above but for One 5 Amps 3/5 pin socket outlet on independent board.
All as per Item No. 5.00 here-in-above but for 15 Amps 5/6 pin socket point on independent board with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire,complete all as specified and as directed.
All as per Serial Item No.5 here-in-above but wiring in existing conduit / casing & caping for one way switch One light/ fan/bell point controlled by one, one way switch 5Amps complete all as specified and directed .
All as per Serial Item No.5 here-in-above but wiring in existing conduit / casing & caping for one 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Serial Item No.5 here-in-above but wiring in existing conduit / casing & caping for one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed.
All as per Serial Item No.5 above but wiring in existing conduit / casing & caping for 15 Amps 5/6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire
S&F in replacement of switch piano, flush button, single pole, one way, 5/6 Amps, 230 Volts complete all as specified and as directed.
S&F in replacement of socket outlet 5 Amps ,3/5 pin 230V AC flush type complete all as specified and directed.
S&F in replacement of switch socket outlet 5 Amps, 3/5 pin 230V AC flush type complete all as specified and directed.
S&F in replacement of switch socket outlet, multipurpose, 3 pin , 5 and 15 Amps, flush type, universal ,230 Volts controlled by one switch complete all as specified and as directed.
S&F in replacement ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals, 230 Volts complete all as specified and as directed.
S&F in replacement bell push, flush type, 5 Amps, 230 Volts complete all as specified and as directed.
S&F in replacement Buzzer, ding dong AC, 230 Volts, single pole complete all as specified and as directed.
S&F in replacement of Electronic fan regulator, stepped type, 100 W, AC, 230 Volts, fixed on existing laminated sheet complete all as specified and as directed.
S&F in replacement of Electronic mini fan regulator, flush type, 100 W, AC, 230 Volts, fixed on existing laminated sheet complete all as directed.
S&F LED light fitting 1X5W bulk head luminaries, with frosted glass cover with lamp holder all accessories including 5 W LED bulb and taking down old fitting complete all as specified and as directed Make : Havells / Bajaj /Philips / CG /Wipro.
S&F in replacement of Ultra bright LED Tubelight, 18 watt, 4 feet, battern (retrofit) with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing T5 fitting with G5 lamp holders, LED driver outside., with all accessories internally pre wired including tube rod and connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old tube rod complete all as specified and as directed Make : Havells Cat Part No.TITANIASLEEK1149T5DSTL18WLED865SPC or techno commercially equivalent model of make Bajaj /Philips / CG /Wipro.
S&F in replacement of Ultra bright LED Tubelight, 9 watt, 2 feet, battern (retrofit) with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing T5 fitting with G5 lamp holders, LED driver outside., with all accessories internally pre wired including tube rod and connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down old tube rod complete all as specified and as directed Make : Havells Cat Part No.TITANIASLEEK549T5DSTL9WLED865SPC or techno commercially equivalent model of make Bajaj /Philips / CG /Wipro.
S&F LED light fitting 18W, 4 feet long, with batten ( integrated driver), 6500K colour temp, aluminium housing decorative type with all accessories internally pre wired with tube rod and connectiong up with twin core twisted flexible copper conductor cable with suitable size including taking down old fitting complete all as specified and as directed Make : Havells Cat Part No. LUMILINEPLUSBS18WLED865SPCSS or techno commercially equivalent model of make Bajaj /Philips / CG /Wipro.
S&F in replacement of 'SKYLUX' Premium recess mounted 36W, (2' x 2') LED panel light luminaire, neutral white color temp, white powder coated CRCA housing with LEDs. Seamless front frame with white coloured flat acrylic cover. with all accessories suitable for armstrong/grid ceiling and prewired including connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old fitting complete all as specified and directed. Make :- Bajaj model No. BZRSQL 36W XL NW or techno commercially equivalent make in CG / Havells / Philips / Wipro .
S&F in replacement of lamp Holder, insulated body with back plate , 230 Volts for batten fitting complete all as specified and as directed.
Supply, Fix ,connecting and testing of 'INTEGRAHE' Recess mounted 7W down light, of 5'' dia round type, with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integral electronic low THD (<10%) LED driver, ceiling cutout: Ø 138 mm, height 90 mm with all accessories including 5W / 7W LED bulb, with all accessories suitable for armstrong/grid ceiling and prewired including connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down unserviceable light fitting complete all as specified and as directed. Make :-Havells Cat Part No. INTEGRAHEDLR7WLED840S or Techno commercially equivalent model of make CG / Bajaj / Philips / Wipro .
Supply, Fix ,connecting and testing of 'EDGEPRO SQUARE' Recess mounted 6W LED down light, square type, Slim-fit low profile, superior light output, uniformity utilising, edge-lit, high lumen output, with all accessories including 6W LED bulb, with all accessories suitable for armstrong/grid ceiling and prewired including connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down unserviceable light fitting complete all as specified and as directed. Make :- Havells Cat Part No.. EDGEPROSQDLR6WLED840S or Techno commercially equivalent model of make CG / Bajaj / Philips / Wipro .
Supply,fix, connecting and testing of LED 25 watt street light luminaries, new generation energy saving and environmental friendly long life, pressure die cast aluminium housing with high efficient with IP66 protection and impact resistance of IK07, heat resistant toughened glass with frame, fixed on pole or wall with GI tubing 25mm bore 1.20m long bent shape as required and 02 Nos brackets made with MS clamp 25x3 mm flat and connectiong up with twin core twisted flexible copper conductor cable with suitable size taking down old fitting complete all as specified and as directed Make : Havells Cat Part No ENDURAPEARLSL25WLED757SASYTOPCMP or techno commercially equivalent model of make Bajaj /Havells / CG /Wipro
S&F in replacement of PVC board of size 30cmX25cmX 5cm depth complete all as specified and as directed.
S&F in replacement of PVC board of size 25cmX20cmX 5cm depth complete all as specified and as directed.
S&F in replacement of PVC board of size 20cmX15cmX 5cm depth complete all as specified and as directed.
M&L for PVC hylum sheet 3mm thick top cover of size 30cmX25cm including taking down old one complete all as specified and directed.
M&L for PVC hylum sheet 3mm thick top cover of size 25cmX20cm including taking down old one complete all as specified and directed.
M&L for PVC hylum sheet 3mm thick top cover of size 20cmX15cm including taking down old one complete all as specified and directed.
M&L for submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including PVC casing & caping fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 6 sqmm and one run of PVC casing & caping shall be measured as one length for the purpose of measurement.
M&L for submain wiring with two runs of 4 sqmm with one run of 4 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including PVC casing & caping fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 4 sqmm and one run of PVC casing & caping shall be measured as one length for the purpose of measurement.
M&L for submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through existing steel conduit and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 6 sqmm shall be measured as one length for the purpose of measurement.
M&L in replacement factory made distribution board in sheet metal enclosure in single door with out bus bar,SPN 2 way, 240V for fixing suitable MCB's complete all as specified and as directed.
S&F in replacement factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 4 way, 240V for fixing suitable MCB's complete all as specified and as directed.
S&F in replacement factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 8 way, 240V for fixing suitable MCB's complete all as specified and as directed.
S&F in replacement factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,TPN 4 way, 415V for fixing MCB's complete all as specified and as directed.
S & F in replacement of MCCB, TPN 4 pole, 100 Amp, 25 KA, 415volts, 50 HZ AC, thermal magnetic release including making necessary modification in existing panel board if required to fix MCCB inclding replacement of incoming and out going cable connection with lugs, Aluminium conductor cable with suitable size, nuts bolts including taking down old u/s existing MCCB with brunt cable & etc, complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCB SPN ‘C’ Curve 10KA, 5 to 32 amps, 240 V complete all as specified and directed .
S&F in replacement MCB SPN ‘C’ Curve 10KA, 40 amps, 240 V complete all as specified and directed .
S&F in replacement MCB SPN ‘C’ Curve 10KA, 63 amps, 240 V complete all as specified and directed .
S&F in replacement MCB SP ‘C’ Curve 10KA, 5 to 32 amps, 240 V complete all as specified and directed .
S&F in replacement MCB SP ‘C’ Curve 10KA, 40 amps, 240 V complete all as specified and directed .
S&F in replacement MCB SP ‘C’ Curve 10KA, 63 amps, 240 V complete all as specified and directed .
S&F in replacement MCB TPN ‘C’ Curve 10KA, 63 amps, 415V complete all as specified and directed .
S&F Blankig plate for filling gap of MCB complete all as specified and directed.
S&F in replacement factory SPN sheet metal enclosure with two pin and earth plug and socket modular type with SP MCB 20 Amps (C-curve-10 KA) complete all as specified and as directed by directed by Engg-in-charge.
Taking down ceiling fan / wall mounting fan ,any size and sweep from its position and transport to workshop for servicing,dismantling for servicing including removal of bearing,bushes,condenser, connector, flaxible cord,split pin etc if required removing old grease and refill fresh, lubricating bushes along with new washers, cleaning and washing fan blades, fan body etc with soap solution after repairing, re- assamble the same and transporting from workshop to any location in Jalipa and fixing to position / location including provision of twisted twin core flexible wire up to 0.7 m long of size 28/0.0076 ISI marked and connecting to electric system as directed, connecting to electric system, testing etc complete all as specified and as directed . Note : -(i) Replacement of parts/rewinding shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store & taking down unserviceable/ defective parts. (iii) Item such as bearings, gun metal bushes, capacitor, shaft etc required for replacement shall be measured and paid seperately as supply only.
Taking down and transporting of exhaust fan any size & any make from any location inside Jalipa Mil Stn to MES E/M Store Yard / Workshop for stripping of fan washing thoroughly of bearing / bush by petrol, washing / cleaning fan blade body etc thoroughly provision of new greasing replacement of worn-out / defective unserviceable parts (wherever necessary) assembling the same after defective / unserviceable parts is replaced including provision of twisted twin core flexible wire upto 0.7 mts long size 23/0.0076 (ISI marked) and re-fixing the same at the same location including making good disturbed surface including testing etc complete all as specified and as directed . Note : -(i) Replacement of parts/rewinding shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store/workshop & taking down unserviceable/ defective parts. (iii) Item such as bearings, bushes, capacitor, shaft etc required for replacement shall be measured and paid seperately as supply only.
M & L spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as directed by Engineer-in-charge.
Supply only fan blades (set of three) of any make / type of ceiling fan of size 1200/1400mm sweep complete all as specified and as directed.
Supply only U clamp complete with nut bolt washer, split pin and rubber weal etc complete all as specified and as directed.
M&L cutting and taking out old burnout winding of any sweep ceiling fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L cutting and taking out old burnout winding of 230 mm sweep exhaust fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L cutting and taking out old burnout winding of 300 mm sweep exhaust fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L for spray painting to exhaust fan any type and size with a coat of Ist quality synthetic enamel paint, colour as approved including preparation of old surfaces, cleaning etc writing the fan numbers etc in black paint complete all as specified and as directed.
Supply only ball bearing suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and as directed.
Supply only gun metal bush suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and as directed.
Supply only condensor 2.5 MFD suitable for ceiling fan of any sweep complete all as specified and as directed.
Supply only condensor 4 MFD suitable for ceiling fan of any sweep complete all as specified and as directed.
Supply only metalic bottom plate of ceiling fan of any sweep complete all as specified and as directed.
S & F in replacement of Exhaust fan, 230 mm sweep, (plastic body), min 3 star rating, with accessories including making necessary connection in existing, complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of Exhaust fan, 300 mm sweep, metallic body, min 3 star rating, with accessories including making necessary connection in existing, complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of Ceiling fan, 1200 mm sweep, min 3 star rating, with accessories including making necessary connection in existing, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of cable / pipe line etc and getting out in soft / loose soil complete all as specified and directed .
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed .
Taking down old/unserviceable under ground LT cable of any cross-sectional area from trenches/walls / poles after dis-connecting connections including cable protection stone slab /covers, pipes etc., complete all as specified and directed by Engineer-in-charge.
Supply and spreading clean dry sand ( Tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
Laying only servieable stone slab ,laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed. Note :- Serviceable stone slab obtained from slitem No.74 of above will be re used.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of 10 Sqmm 2.0 core, 1100 volts grade with stranded aluminium conductor served with an inner sheathing of PVC tape including providing lugs jointing materials, gland etc as required and connection, testing complete all as specified and as directed.
All as per item no. 78 here-in-above but cable size 16 Sqmm 2.0 core,
All as per item no. 78 here-in-above but cable size 25 Sqmm 3.5 core,
S&F in replacement of GI tubing , light grade of 40mm bore with fittings fixed to wall / pole or laid in floor or hard standing / road crossing for cable protection including clamping of pipe with MS flat of size 50mm long of 12mm dia including nut, bolt & washers of size 50X12mm whereever required incld taking up / down / out old existing tube complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanized earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using 4 MM dia of galvanized iron earth wire by means of bolts, nuts, check nuts and washers made of galvanized earth and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 3 of SSR Part I (2009) and Part II (2010) incl dismanteling of existing unserviceable earth pit complete all as specified and directed by Engr-in-Charge. Note: 1. The earh resistant value must be well below of 5 ohm irrespective to seasons and any unforeseen condition. 2. Earth should be free from stone.
M/S PRASHANT BENIWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .