Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | Admitted-Finance |
| 4 | Admitted-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair Maint of HT LT OH Line including detection of cable fault in the area of Shankar Vihar Yogender Vihar Vikram Vihar VRC OTM I to III Bana Singh Rangpuri of AGE U Elect Supply No III under GE U Elect Supply Delhi Cantt 10
2020_MES_356040_1
GE ELECT/D-44/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE U ELECTRIC SUPPLY
₹80,000
Yes
4 Sept 2020
31 Jul 2020
29 Aug 2020
1 Aug 2020
27 Aug 2020
22 Aug 2020
60 days
Amount
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 01 above but 1100 Volt LT cables
All as per item Ser No 01 above but 33000 Volt LT cables
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge
S&Laying in replacement sub class B bricks having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per Srl item No 8 here in before but using old bricks obtain under item No 1.
Supply and lay in replacement unreinforced precast concrete cable covers class HV Type -1 with peak size 300 x 180 x 40 mm. compete all as specified and directed
All as per srl item No 10 here-in-before but using old tiles obtained under srl item No 1.
Supply, Laying, connecting, testing and commissioning in replacement ( including taking out existing cable) LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded , 4 core,10 sqmm, after taking out/down old existing unserviceable from trenches / ducks/ road crossing and poles complete all as specified and directed. NOTE : Excavation and earth work, cable protection (GI Pipe), sand filling,cable joint shall be measured and paid separately under respective items of schedule.
All as per srl item No 12 here-in-before but size of 3.5 core, 25 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 35 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 50 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 70 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 95 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 120 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 185 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 240 to 300 sqmm.
Supply jointing and testing straight through, heat shrinkable jointkit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 4 core,10 Sqmm and including taking from faulty portion in any situation/position complete all as directed.
All as per srl item No 21 here -in-before but size of 3.5 core, 25 to 50 Sqmm.
All as per srl item No 21 here -in-before but size of 3.5 core, 70 to 120 Sqmm.
All as per srl item No 21 here -in-before but size of 3.5 core, 185 to 300 Sqmm.
Supply, laying, jointing and testing in replacement (Including takingout existing cable) XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 Sqmm,11 KV grade (earth) for 11 KV (E) system, laid in trenches/ducts/encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed
All as per srl item No 25 here -in-before but size of 3 core,240 sqmm.
All as per srl item No 25 here -in-before but size of 3 core,185 sqmm.
All as per srl item No 25 here -in-before but size of 3 core,120 sqmm.
Supply, jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
All as per srl item No 29 here -in-before but size of 3 core,120 to185 sqmm.
Supply, jointing and testing, indoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
All as per srl item No 31 here -in-before but size of 3 core,120 to185 sqmm.
Supply, jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
All as per srl item No 33 here -in-before but size of 3 core,120 to 185 sqmm.
Supply, laying, jointing and testing in replacement (Including takingout existing cable) XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 Sqmm,33 KV grade (earth) for 33 KV (E) system, laid in trenches/ducts/encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed
Supply, jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 Sqmm.
Supply, jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 Sqmm.
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 50mm dia. complete all as specified and directed
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 80 mm dia. complete all as specified and directed
M&L for replacement of unserviceable jumper of ACSR Conductor with new jumpers of ACSR conductor of suitable size including binding properly on the existing OH line/ 4 pole structure with clamp, nuts & bolts etc.complete all as specified and directed.
M&L for disconnecting burnt end termination or portion of cable removing the cable from loop including necessary excavation & earth work, suitable size of thimble, LT tape, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals for 50 Sqmm to 70 Sqmm 3.5 core along with replacement of existing corroded Nuts bolts and washers with new GI nuts bolts and washers at LT cable to pole/LT panel/main switch/transformers complete all as specified.
All as per item No 41 above but of size 95 to 120 Sqmm.
All as per item No 41 above but of size 150 to 185 Sqmm.
All as per item No 41 above but of size 240 to 400 Sqmm.
M&L for boring of holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including material and labour for HDPE pipe of 160 mm dia suitable for 06 Kg/cm2 working pressure. Wall thickness of pipe not less than 6.5 mm.
M&L for danger notice board of 1.6 mm thick mild steel,vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size for HT 25 x 20 CM size complete.
Supply and fix cable route indicator made of RCC with 8 mm TMT size 1.5 M height x 60 cm wide x 10 mm thick tapered on top visible above ground duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 11000 volts will be given by Engr-in-charge complete all as specified and directed.
Demoletion of PCC from path any position and M&L for PCC in foundation filling and mass concrete type C2 (1:3:6) using 40 mm grded aggregate for foundation of pole complete all as specified
Demoletion of PCC from path any position andM& L for PCC type B1 (1:2:4) using 20 mm graded aggregate for pedestal of poles including use and waste of formwork complete all as specified
Supply only following expendable items for replacement : (a) CRC liquid 300 ml bottle.
cotton waste
Fuse wire 100 Amp
Fuse wire 60 Amps
Fuse wire 40/30 Amps
PVC insulation tape of thickness 0.125 mm 25 mm width 25 Mtr length.
HT insulation tape of thickness 25 mm width 25 Mtr length. Make : BIRLA 3M
Rubber resin/self amalgamating electrical tape for 11 KV HT supply 3/4" width 30' length. Make : 3M Scotch/godson/Max Electric.
Heat shrinkable sleeves size 1/2" - 2" Max temp 120 degree centrigate 1 KV. Make : 3M/Raychem.
HT Busbar sleeves 2 mm 115 degree centrigrate 15 KV 35 to 200 mm. Make : 3M/Raychem.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
Vijay Electricals
Powerlite Engineers
M/s Adhikari construction co.
Buddham Builders
mayur enterprises
DS CONSTRUCTION
Microsys Controls India
Ridhi engineers and builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .