Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.3 LAccepted-AOC | 1 | Accepted-AOC accept | |
| 2 | 2₹13.5 L+₹17,875 (1.34%)Rejected-AOC | 2 | Rejected-AOC reject | |
| 3 | 3₹16.1 L+₹2.8 L (20.9%)Rejected-AOC | 3 | Rejected-AOC reject | |
| 4 | 4₹16.6 L+₹3.3 L (24.8%)Rejected-AOC | 4 | Rejected-AOC reject | |
| 5 | 5₹17.1 L+₹3.8 L (28.4%)Rejected-AOC 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | 5 | Rejected-AOC reject |
Tender Value
₹19.5 L
EMD Value
₹19,500
Closing Date
16 Apr 2024, 12:00 pmClosed
SE EWC
Bareilly
Laying of 33 KV Underground Cable and Reconductoring of 33 KV lines at various Sub-Station
2024_MVVNL_920617_1
98/EWC(B)/2023-24
Open Tender
Electrical Works
Item Rate
30 days
Badaun
As per tender document
3 documents required · 3 mandatory
₹3,540
SE EWC
₹19,500
7 Sept 2024
28 Mar 2024
16 Apr 2024
28 Mar 2024
16 Apr 2024
28 Mar 2024
Amount
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
33 KV 3X300mm2 XLPE Cable
33 KV 3X300mm2 XLPE Cable jointing kit O/D
33 KV 3X300mm2 XLPE Cable jointing kit S/through
ST pole 11 Mtr. Long
9.0 M long PCC pole
33 KV cross arm
33 KV pin insulator
33 KV pin with nut
M.S. Earthing rod
M.S angle 65x65x6mm, 2700mm
Top channel 125x65x6mm 3200mm
T- Off Channel 125x65x1300mm
ACSR Dog conductor
11 KV disc insulator B&S type 70 KN
Disc fitting Dog/Racoon 70 KN
Complete Stay set complete
Gaurding angle 65x65x2950
G.I wire 8 Swg
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All types of clamps nuts & bolts,stone pad, washer would be provided by contractor.
Single line support on PCC Pole 09 Metre
Single line support on ST Pole 11 Metre
Cable exposer double pole on 11m long ST pole
End Type double pole structure on ST Pole 11 Metre
Section double pole structure on ST Pole 11 Metre
Four Pole Structure with ST Pole 11m
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
Laying and sagging of 3 phase ACSR Dog conductor in 33KV existing line including jumpering, hoisting, fixing of all type of insulators,armor rod, ferrule, binding, jointing and its clamping etc. in all respect.
Safe dismentling of old & rotten ACSR Dog, Weasel conductor of existing 33 KV line without damage of any insulator, clamp etc.
Dismantaling of old damage 33kv cross arm (6 No.) and 33kv insulators (66 No.) and erection of new 33kv cross arm (6 No.) and 33kv insulators (66 No.) in place of damage 33kv cross arm and 33kv insulators.
Fabrication and fixing of guarding angle on Single/double poles, Stringing and sagging of three nos. Earth/GI wire with cardle guarding of above 33 KV line as per RESSPO Norms including provision of all necessary clamps and hooks. Shifting of existing line conductor of 11 KV/LT line to maintain proper clearance in between both lines (all required material will be provided by the contractor except guarding angle and earth/GI wire).
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
Single line support on ST Pole 11 Metre
Cable exposer double pole on 11m long ST pole
End Type double pole structure on ST Pole 11 Metre
Section double pole structure on ST Pole 11 Metre
Four Pole Structure with ST Pole 11m
Fixing of danger board and number plate on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
Write serial number on each pole in English with black paint in yellow paint background. (All material would be provided be firm.)
Cable laying by drill method single circuit in HDPE Pipe.
Cable laying by drill method single circuit.
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D or I/D Cable Jointing Kit
Fixing of 33 KV S/Th Cable Jointing Kit
Fixing of cable route marker.
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of Incharge.
Loading. unloading and safe carrige of old & rotten Dog, Weasel conductor from site to Store centre, Badaun.
M/S TIWARI TRADING COMPANY
M/S HINA ELECTRICALS
M A ELECTRICALS
SHIV TRADERS
M/s S.S. Refregeration
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .