Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC ESSENN KUDIL NO 46 1ST STREET SIVANANDHA NAGAR KOLATHUR CHENNAI 600 099 | CHENNAI | CHENNAI | TAMIL NADU | 600099 | L1 | Accepted-AOC WU issued to L1 bidder | |
| 2 | L2₹16.0 L+₹4,151 (0.26%)Rejected-AOC | L2 | Rejected-AOC WU issued to L1 bidder | |
| 3 | L3₹18.3 L+₹2.4 L (14.8%)Rejected-AOC | L3 | Rejected-AOC WU issued to L1 bidder | |
| 4 | L4₹19.3 L+₹3.3 L (20.9%)Rejected-AOC REVENUE WARD 8 8 2 220 GANDLA STREET SULLURU SULLURPET NELLORE ANDHRA PRADESH 524121 | SPSR NELLORE | ANDHRA PRADESH | 524121 | L4 | Rejected-AOC WU issued to L1 bidder |
Tender Value
₹20.9 L
EMD Value
₹41,740
Closing Date
13 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)
Engineering Unit, Admin Block 3rd Floor, IIT Madras, CHENNAI-600036
Providing Power connection to CBEEV Lab in ESB annex building at IIT Madras
2022_IITM_127368_1
18/2022-23/ELDB
Open Tender
Electrical Works
Item Rate
60 days
IIT MADRAS CHENNAI-600036
All required documents as specified in the tender
2 documents required · 2 mandatory
₹0
₹41,740
8 Dec 2022
30 Aug 2022
14 Sept 2022
31 Aug 2022
13 Sept 2022
2 Sept 2022
1 Sept 2022 - 2 Sept 2022
Amount
Kiosk MV PANEL
Supply , Erection,Testing and commissioning of suitable size extendable cubical type following outdoor type Kiosk LT Main Panel board suitable for 415V 3ph 4 wire 50Hz AC supply system fabricated in a compartmentalized design from CRCA sheet steel of 2mm thick for frame works and cover with 3mm thick removable gland plate ,cleaning and finishing with 7 tank process for powder coating with siemens grey having extensible type 4P copper alloy busbar of suitable capacity as per the incomer MCCB ratings with DMC/SMC busbar suppotrs with short circuit withstand capacity of 31MVA / 1Second , bottom base channel of 75mmX 50mm X 5mm in a suitable pedastal of 0.5m above the FFL with necessary masonary work. BASBAR: Bus bars will be electrolytic copper , air insulated , R,Y,B, N(Black) PVC sleeved capable of carrying full load current for all the 3 phases and neutral continiously. The current density of copper shall be designed for 1.3 A per sqmm. The bus chamber should have proper air ventilators.
EARTHING: 2 separate run of 25 x 3 mm copper earth bus painted in green colour should be provided all along the panel and connected to the earth pits. Interconnectios should be taken to metering chamber, MCCB's so that all current carrying components are effectively earthed. 3 phase indication lamps with toggle switch-2set, microprocessor based digital multi function meter with communication port and the facility for active and reactive power measurements -5set with required CTs and control fuses etc.Necessary Spreaders / extended copper bus bars of suitable rating with required holes should be provided for the cable and bus bar terminations.The handle should be pad lockable type in both ON/OFF positions. The scope of work includes minor civil works like breaking of concrete floors ,construction of masonary trench, and suitable MS 'П' type channels for the proposed panel as per the instruction from the Engineer in Charge.The rate should be inclusive of removing of existing LTUG cable terminatins from the panel or cable trench or excavated from earth if any. The cable should be re terminated after completion of all the erection works. Necessary Panel drawings , QAP and GTP have to be approved by the Engineer incharge before fabrication. The out door panel should contains following items:
PANEL -1 Kiosk Type
Incomer
800A TPN MCCB 50kA with micro processor based trip units ,Harmonic filters of suitable rating & front operated handle and with ON/OFF/TRIP indications-1 nos ( incoming cable 2Rx 3.5C x 400 Sqmm LTUG cable)
Outgoing
630A TPN MCCB 36kA with micro processor based trip units ,front operated handle and with ON/OFF/TRIP indications- 2Nos ( 1 feeder - 2R x3.5C x 300 Sqmm LTUG cable and other feeder 1 R x3.5Cx 400 Sqmm LTUG Cable)
PANEL -2 Indoor Type
Incomer
630A TPN MCCB 36kA with micro processor based trip units ,front operated handle and with ON/OFF/TRIP indications- 1Nos ( 1R x 3.5C x 400 Sqmm LTUG cable)
Outgoings
400A TPN MCCB 36kA with micro processor based trip units ,front operated handle and with ON/OFF/TRIP indications- 1No ( 1R x 3.5C x240Sqmm LTUG cable)
250A TPN MCCB 36kA with micro processor based trip units ,front operated handle and with ON/OFF/TRIP indications- 2Nos
125A TPN MCCB 36kA with micro processor based trip units ,front operated handle and with ON/OFF/TRIP indications- 2Nos ( 1R X 150 Sqmm LTUG Cable /each)
Supplying and fixing of 630A 36kA TPN MCCB with enclosure and suitable cable entry boxes for Incoming and Outgoing cables ( each 2R x 300 Sqmm LTUG Cable) on a frame work to be mounted on wall wirh necessary earth connections . The MCCB enclosure shouild have 3Phase indications 1 Set, multifunction meter with CT's, Front operated rotary handle and ON/OFF/TRIP indications.
CABLES Laying & End Terminations
Supplying& Laying of following sizes PVC XLPE insulated alu. Conductor armored 1.1kV LTUG cable in a suitable 50 mm to 100 mm dia HDPE DWC pipe in a trench of 50cm wide and 75cm depth including earth work excavation in all soils and sub soils and back filling, consolidated in a regular interval of 25cm thick rammed and complying with standard specification. Cable to be laid on the wall with propper clamps complying and with standard specification and both the end of the cable to be marked the source and destination whichever is required with standerd marking procedure as per IE rule)
3.5C x 400 Sqmm
3.5C x 300 Sqmm
3.5C x 240 Sqmm
3.5C x 150 Sqmm
Supplying and making end termination for following sizes alu. Conductor LT UG cable using suitable compression gland with required copper ferulles / socket and other jointing materials
3.5C x 400 Sqmm PVC XLPE
3.5C x 300 Sqmm PVC XLPE
3.5C x 240 Sqmm PVC XLPE
3.5C x 150 Sqmm PVC XLPE
VTPN DB
The double door type 8 Way VTPN MCB DB With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.comprising of the following :
VTPN DB no. 1: Incoming: 125A TPN 15kA MCCB.( Providing and fixing following rating and breaking capacity and MCCB with thermomagnetic release and terminal spreaders in existing DB including drilling holes in DB if any, making connections, etc. as required.) – 1 No. Outgoing: 40 A TP MCB – 1 Nos. with 5 Nos 6-32 A TP MCB 'C' Curve, 1no of 63A SP & 5 Nos 6-32A SP MCB 'C' Curve
VTPN DB no. 2: Incoming: Incoming: 125A TPN 15kA MCCB.( Providing and fixing following rating and breaking capacity and MCCB with thermomagnetic release and terminal spreaders in existing DB including drilling holes in DB if any, making connections, etc. as required.) – 1 No. Outgoing: 63 A TP MCB – 1 Nos., 6-32 A TP MCB-01 No.with 18 nos of 6-32A SP MCB 'C' Curve
EARTHING
Supply installation of Chemical Earthing with 25mm dia copper bonded rod of 3000mm length rod with required chemical bags and covering with masonary works .
Supplying and laying of following size earth flats at 0.50 mt below the earth including soldering/welding as required
16 Sqmm Copper cable
25 x 5mm copper strip
Delhi Electrical Construction
Immanuel Electricals
M/s. CHANDRA REDDY ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .