Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAdmitted-Finance 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | L1 | Admitted-Finance | |
| 2 | L2₹3.1 Cr+₹15.5 L (5.21%)Admitted-Finance 1804 SECTOR 2 HUDA 124001 | ROHTAK | HARYANA | 124001 | L2 | Admitted-Finance | |
| 3 | L3₹3.4 Cr+₹46.5 L (15.6%)Admitted-Finance 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICAION 124103 | JHAJJAR | HARYANA | 124103 | L3 | Admitted-Finance | |
| 4 | L4₹3.6 Cr+₹57.9 L (19.5%)Admitted-Finance 314 20 SHAKTI NAGAR GURUGRAM 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S SHREE BALAJI BUILDERS L1 | Narender Singh Contractor L2 | Chahar Construction Co L3 | Guru Engineering Works L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Repairing water supply line/ leakage in 200 mm i/d pipe line with JCB breaker for depth upto 2 m | 60 | Nos. | 3,000 ₹1,80,000 Lowest | 4,800 ₹2,88,000 | 6,500 ₹3,90,000 | 5,500 ₹3,30,000 |
| 2.00 | Repairing water supply line/leakage in 100 mm i/d pipe line for depth upto 1 m | 600 | Nos. | 2,200 ₹13,20,000 | 2,100 ₹12,60,000 | 10 ₹6,000 Lowest | 2,600 ₹15,60,000 |
| 3.00 | Repairing water supply line/ leakage in 150 mm i/d pipe line for depth upto 1 m | 420 | Nos. | 2,800 ₹11,76,000 | 3,600 ₹15,12,000 | 10 ₹4,200 Lowest | 3,000 ₹12,60,000 |
| 4.00 | Repairing water supply line/ leakage in 100 mm i/d pipe line with JCB breaker for depth upto 1 m | 480 | Nos. | 2,800 ₹13,44,000 | 2,400 ₹11,52,000 Lowest | 4,500 ₹21,60,000 | 4,000 ₹19,20,000 |
| 5.00 | Repairing water supply line/ leakage in 150 mm i/d pipe line with JCB breaker for depth upto 1 m | 420 | Nos. | 2,800 ₹11,76,000 Lowest | 3,300 ₹13,86,000 | 5,000 ₹21,00,000 | 4,200 ₹17,64,000 |
| 6.00 | Repairing water supply line/ leakage in 200 mm i/d pipe line with JCB breaker for depth upto 1 m | 60 | Nos. | 3,500 ₹2,10,000 Lowest | 4,800 ₹2,88,000 | 6,000 ₹3,60,000 | 6,370 ₹3,82,200 |
| 7.00 | Repairing water supply line/ leakage in 250 mm i/d pipe line for depth upto 1 m | 60 | Nos. | 4,500 ₹2,70,000 | 3,600 ₹2,16,000 | 10 ₹600 Lowest | 4,641 ₹2,78,460 |
| 8.00 | Repairing water supply line/ leakage in 250 mm i/d pipe line with JCB breaker for depth upto 1 m | 120 | Nos. | 5,000 ₹6,00,000 | 4,800 ₹5,76,000 Lowest | 6,500 ₹7,80,000 | 6,260 ₹7,51,200 |
| 9.00 | Repairing water supply line/ leakage in 300 mm i/d pipe line with JCB breaker for depth upto 1 m | 30 | Nos. | 5,100 ₹1,53,000 Lowest | 5,100 ₹1,53,000 Lowest | 7,000 ₹2,10,000 | 6,400 ₹1,92,000 |
| 10.00 | Supply and topping of 200 KVA and 315 KVA transformer Silicone Transformer Oil - High Dielectric Strength Fluid in conservator tank and including replacement of dirty silica gel in transformers. | 600 | Litre | 120 ₹72,000 | 81 ₹48,600 Lowest | 100 ₹60,000 | 108 ₹64,800 |
Tender Value
₹4.1 Cr
EMD Value
₹8.1 L
Closing Date
24 Aug 2026, 12:00 pmClosed
Parveen Kumar Raghav
Municipal Corporation Gurugram
Operation and Maintenance of boosting station and water supply system in Ward 02,03,04 for financial year 2026-28 under the jurisdiction of Zone-V, in MCG.
2026_HRY_540006_1
2026A6F89DC4 3033 4E8A 9C7A 936C5F21CB81285ULB
Open Tender
Civil Works
Works
790 days
Gurugram
2 documents required · 2 mandatory
₹15,000
₹8.1 L
Yes
16 Sept 2026
10 Aug 2026
24 Aug 2026
10 Aug 2026
24 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repairing water supply line/ leakage in 200 mm i/d pipe line with JCB breaker for depth upto 2 m | 60 | Nos. | - | - |
| 2 | Repairing water supply line/leakage in 100 mm i/d pipe line for depth upto 1 m | 600 | Nos. | - | - |
| 3 | Repairing water supply line/ leakage in 150 mm i/d pipe line for depth upto 1 m | 420 | Nos. | - | - |
| 4 | Repairing water supply line/ leakage in 100 mm i/d pipe line with JCB breaker for depth upto 1 m | 480 | Nos. | - | - |
| 5 | Repairing water supply line/ leakage in 150 mm i/d pipe line with JCB breaker for depth upto 1 m | 420 | Nos. | - | - |
| 6 | Repairing water supply line/ leakage in 200 mm i/d pipe line with JCB breaker for depth upto 1 m | 60 | Nos. | - | - |
| 7 | Repairing water supply line/ leakage in 250 mm i/d pipe line for depth upto 1 m | 60 | Nos. | - | - |
| 8 | Repairing water supply line/ leakage in 250 mm i/d pipe line with JCB breaker for depth upto 1 m | 120 | Nos. | - | - |
| 9 | Repairing water supply line/ leakage in 300 mm i/d pipe line with JCB breaker for depth upto 1 m | 30 | Nos. | - | - |
| 10 | Supply and topping of 200 KVA and 315 KVA transformer Silicone Transformer Oil - High Dielectric Strength Fluid in conservator tank and including replacement of dirty silica gel in transformers. | 600 | Litre | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_619294.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .