Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹49.3 L+₹1.2 L (2.42%)Rejected-Finance | L2 | Rejected-Finance Not being L1. | |
| 3 | L3₹49.6 L+₹1.5 L (3.10%)Rejected-Finance | L3 | Rejected-Finance Not being L1. | |
| 4 | L4₹50.3 L+₹2.2 L (4.59%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance Not being L1. | |
| 5 | L5₹50.5 L+₹2.4 L (4.98%)Rejected-Finance | L5 | Rejected-Finance Not being L1. |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
6 Sept 2024, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT OF DOOR WINDOW WALL PANELLING AND CERTAIN BR WORKS AND REPAIR REPLACEMENT OF CORRODED GI CI PIPE LINES TO DI PIPE LINES UNDER GE I GOS
2024_MES_667986_1
8000/042/2024-25/0941/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
As per Tender Documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹90,000
9 Apr 2025
25 Jul 2024
7 Sept 2024
25 Jul 2024
6 Sept 2024
9 Aug 2024
Amount
Taking down UPVC door and windows/ventilator of any size and of any description built in wall and making good at disturbed surface with cement mortar 1:4 complete all as specified & directed.
Taking down wall panelling and similar work complete alll as specified and directed
S & F Moulding as in cornices, picture rails and the like exc 13 & n.exc 25 sqcm Fillet wrought complete all as specified and directed.
M&L 12 MM thick Plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed.
M & L 1 or 0.90 mm thick Decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed.
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as shown on drawing in section 8 of SSR-2010 Part-II complete all as specified and directed
S&F solid PVC Wall Lining consisting of 5mm thick Plain colour printed PVC Sheet inclusive of solvent cement and fixing at site on PVC Frame all as per specified and directed.
S&F for 25mm dia Stainless Steel Curtain Rod with brackets incl T/D of any type old curtain rods complete all as specified and directed
Hacking out old broken glass (any thickness, size quality or description) form wooden frames or steel,Alu, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm fixed with stainless steel wire staples or with necessary beads complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre,pulp,insulation,etc)or insulation boards/slabs/blankets,any thickness,including cover fillets. complete alll as specified and directed
Providing & fixing false ceiling at all heights with Semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter?locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main?T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L?shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in?Charge.
M&L for applying 3 mm thick wall care Putty in two layers on ceiling surfaces absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper including and applying two coats of Oil bound distemper on ceiling complete complete all as specified and directed.
M&L 8 mm thick exposed metal frame ceiling with calcium silicate board of size 600 x 600mm size board of siliceous and calcareous material reinforced with cellulose fibre for fixing in grid incl Gl frame work for ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified.
Excavation of trenches in any type of soil n.exc 1.5 M wide and n.exc 1.5 M in depth for taking out/laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and as directed.
Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed
Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr. Above starting point complete all as specified and directed.
M& L for MS/CI/DI fittings up to 150mm bore such as collar, bends (any type radius, any angle, double end socketted or double flanged or spigot & socket, tail pieces (all socketed or all flanged with an equal & other end tapering bellmouth or flanged plates, connecting pieces straight (both end flanged or socketed of socket & flanged & spigot ends or bellmouth tailpieces ( one end flanged & other end spigot or socket or tapering as bell mouth or flanged ) caps blank flanges heavy duty suitable for mechanical joint/flanged joint with and incl taking down old fitting of any type and any size complete all as specified and directed.
Supply , laying, jointing & testing of 200mm dia DI Type K-7 pipe with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches complete all as specified and directed by Engr in charge. Make: Jindal/TATA STEEL/Electro steel or technocommercialy equivalent in other make. (Excavation and earth work, DI specials will be measured and paid seperately)
All as per item No 22 above but Bore of pipe 150mm dia
All as per item No 22 above but Bore of pipe 100mm dia
All as per item No 22 above but Bore of pipe 80mm dia
M & L for mechanical type joint made of MS sheet of size 6/8 mm thick along with rubber gasket nuts bolts and washers suitable for 80 mm bore dia of CI/DI pipe. Including Taking up or down old u/s joint all as specified and directed.
All as per item No 26 above but 100 mm bore dia
All as per item No 26 above but 150 mm bore dia
S&F in replacement of sluice valve 300 mm bore class PN - 1.6 with flanged and iron wheel head ,shut and open directed cast on it and including jointing materials,rubber gasket suitable size nut bolts and washer etc complete all as specified and directed. Make :Upadhay/Zoloto/Kirloskar or equivalent
All as per Item No. 29 above but 200 mm bore.
All as per Item No. 29 above but 150 mm bore.
All as per Item No. 29 above but 100 mm bore.
All as per Item No. 29 above but 80 mm bore.
Taking down 0ld unserviseable Run lead joint and M&L for run lead joint of size 80 mm dia complete all as specified and directed
All as per Item No 34 above but 100 mm bore.
All as per Item No 34 above but 150 mm bore.
All as per Item No 34 above but 200 mm bore.
All as per Item No 34 above but 300 mm bore.
All as per Item No 34 above but 400 mm bore.
All as per Item No 34 above but 450 mm bore.
Dismantling of old unserviceable and M & L for Construction of Brick masonry valve chamber of size 1500x1500x1500 mm (internal dimension) chamber depth to be reckoned from the top of PCC foundation to top of brick wall, including PCC1:4:8 type D2 in foundation PCC 1:2:4 type B1 in coping, brick work in cm 1:4, plaster 15 mm thick in CM 1:4 flush pointing externally as the work proceeds, MS Sheet cover 3.00 mm thick with handle and locking arranging and angle iron frame of size (25 x 25 x 5 mm) including painting with two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
M/S. KISHAN ENGINEERING (BID ID -3084848)
M/s M M Engineering Systems (BID ID -3084307)
R J ENTERPRISES (BID ID -3087368)
M/S S. N. ENTERPRISES (BID ID -3088131)
M/S.J.BIJAYA KUMAR PATRO (BID ID -3089503)
M/S JAGANNATH SASMAL (BID ID -3084181)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .