Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC DADRA AND NAGER HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹50,617 (2.13%)Rejected-AOC 475 OPP DAMAN GANGA COLONY GAYTRI MANDIR ROAD AMLI SILVASSA 396230 U T OF D NH | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396230 | L2 | Rejected-AOC L2 |
Tender Value
₹21.7 L
EMD Value
₹43,500
Closing Date
17 Jun 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (R nd B),PWD,WD-I,DNH,Silvassa
PWD Campus Block No.I(Bldg),DNH,Silvassa
Pre-monsoon Preparedness works at Shri Vinoba Bhave Civil Hospital, Silvassa
2024_UTDNH_7062_1
E-TENDER NOTICE NO. 01 OF 2024-25 (BLDG)
Open Tender
Civil Works - Buildings
Item Rate
60 days
UT OF DNH
As per NIT refer
3 documents required · 3 mandatory
₹500
Executive Engineer (R nd B),PWD,WD-I,DNH,Silvassa
₹43,500
20 Jun 2024
10 Jun 2024
17 Jun 2024
10 Jun 2024
17 Jun 2024
10 Jun 2024
Amount
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil
Providing and erecting the water proof mandap (Shamiyana) with necessary frame work of Bamboos and Round wooden posts from ballies with Tarpolin/Tadpatri/plastic lining (water Proof) over ceiling on hire basis.
Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete including cost of formwork in (A) Foundation and Plinth.etc complete as directed by engineer-in-charge.
Providing Corrugated G.I. sheet of Class-3 roofing fixed with galvanised iron J or L Hooks, Bolts and nuts 8 mm diameter with bitumen and G.I. limpet washer or G.I. limet washer filled with white lead complete excluding the cost of purlins, rafters and Truses (1) 0.80 mm thick sheet.
Providing, laying and jointing in true line and level 25mm dia. U.P.V.C. pipe (SCH-40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer in charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing and fixing PVC SWR pipes IS 13592 for Drain. 75mm dia.
Providing and fixing PVC SWR pipes IS 13592 for Drain. 110mm dia.
Providing Ridges or Hips 600 mm overall in plain G.I. sheet class -3 fixed with G.I.J. or L hooks and nuts 8mm dia G.I. limpet and bitumen washer complete (1) 0.80 mm thick sheet
Providing and fixing 150 mm wide 450mm over all semicircular plain G.I. sheet class-3 gutter with iron brackets 40mm x 3mm size bolts, nuts, washers etc. including making necessary connection with rain water pipes. (i) 0.80 mm thick sheet.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Cleaning the existing surface, Providing & Laying water proofing treatment in Double Layer to terrace with APP ( Arctic Polypropylene Polymer) Modified Pre- Fabricated Five Layer Water Proofing Membrane, HYDROSTOP of TIKI DAN make, comprising of 1st Layer of 3 mm thick and minimum 3.5 kg/sq.mtr. weight membrane Hydrostop 3PY M, upper surface Finished in Minerals and Bottom Surface Finished in Plastic Polyethylene Film and having the reinforcement of Non-Woven Polyester Mat at Core, including a coat of Bitumen primer TIKI PRIMER-S for Bitumen Membrane Manufactured to IS:3384. Over the dried primer coat, Laying the APP membrane HYDROSTOP in DOUBLE LAYER using of 2nd Layer to the first, while maintaining the side overlap100 mm and End overlap 150 mm, Sealing all overlap etc. complete, including the treatment at all junctions and corners to accommodate stresses with 300mm wide strip of 3 MM HYDROSTOP 3PYP and treatment over the vertical plane up-to 200 mm height above the finished floor level with 3MM APP membrane 3PYM. The water proofing membrane terminated by tucking it into the groove made on vertical plane, the groove sealed with Cement-Sand Mortar, etc, all complete. The Joints of the top Layer of HYDROSTOP 3PY M Should be released with TIKI BOND.
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of read lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like.
Providing and applying the elastomeric joint sealant two component, high performance polysulfide formulation conforming to BS:4254 and ASTM C 920 having weathering resistance to ultra-violet rays and shall exhibit shore A hardness of 25 and have movement accommodation factor 25% including using of compatible primer of approved standard etc. complete. For 20 mm thick joint
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width
Providing & Fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts, & nuts 8 mm dia. G.I. Plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confirm IS 10192 and IS 12866. The sheets shall be opaque or translucent, clear or pigented, textured or smooth as specified. 2 mm thick corrugated (2.5"or 4.2"or 6") Step-down (2" or 3" or 6") as specified.
S K PARMAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .