| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-Finance | L1 | Accepted-Finance it is the lowest bidder. Hence, the bid may accepted. | |
| 2 | Rejected-Technical | - | Rejected-Technical It is highest bidder. hence, the bid Rejected. |
Tender Value
₹12.7 L
EMD Value
₹12,700
Closing Date
10 Nov 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, L.I. Division, Paralakhemundi
O/o E.E L.I. Division, Paralakhemundi, At- Gourachandrapur, Opposite-Centurian School, Dist- Gajapati
Revival and Energisation of L.I. Projects
2020_OLIC_63463_2
03/2020-21 OLIC (PKD)
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
90 days
Vinola under Gosani Block
Please refer Tender documents
3 documents required · 3 mandatory
₹6,000
E E, L.I Division, Paralakhemundi
₹12,700
Yes
13 Feb 2021
2 Nov 2020
11 Nov 2020
2 Nov 2020
10 Nov 2020
2 Nov 2020
2 Nov 2020 - 8 Nov 2020
180 days
Amount
Schedule A(Civil works & Materials)
Earth work in excavation in hard soil in foundation within 50 mtr. initial lead & 1.5 mtr. initial lift including dressing & levelling the bed as per direction of. Engineer-in-charge.
Filling F&P with excavated hard soil including rough dressing & levelling, breaking clods to minimum size 5 cm to 7 cm as per direction of E.I.C.
Filling F&P with sand well watered as per direction of E.I.C.
C.C(1:4:8) with 4 Cm. size H.B.G metal etc. complete with curing as per direction of Engineer-in-charge
C.B Brick ( 23 Cm X 11 CmX 8CM) masonry work in cement mortar(1:6) with curing etc.complete as per direction of Engineer-in-charge
CC Work (1:2:4) with 12mm size hard broken granite chips complete with curing as per direction of Engineer-in-charge.
RCC Work (1:2:4) with 12mm size hard broken granite chips complete with curing as per direction of Engineer-in-charge.
Labour charges for M.S.Rod cutting, bending, binding & tying the grills & placing in position including cost of binding wire etc.including cost of M.S.Rod complete as per direction of Engineer-in-charge for R.C.C work.
Rigid smooth centering and shuttering for RCC works including false works and dismantling then after casting including cost of materials complete for slab. (A) for coloumn,beam and tie beam.
Rigid smooth centering and shuttering for RCC works including false works and dismantling then after casting including cost of materials complete for slab. (B) for roof slab, lintle etc.
12 mm thick cement plastering with cement mortar(1:6)over brick work with curing etc.complete.as per direction of Engineer-in-charge
Labour charges for White washing two coats with shell lime as per direction of Engineer-in-Charge.
Labour charges for colour washing two coats with shell lime as per direction of Engineer-in-Charge.
Salient feature writing on display board including cost of red oxide paint and enamel paint
Red Oxide
Cost and labour charges for fixing of M.S. Door & window in proper position including required fittings,transportation etc as per direction of EIC .(32 mmx 32mm angle iron frame choukat,25 mmx25mm frame with 18 swg.MS sheet. D size-0.8mx 1.8 m, W size- 0.60mx 0.75 m)
Cost and labour charges for fixing of ventilator in proper position including required fittings,transportation etc as per direction of EIC .
Labour charges for Painting two coats to door, window and ventilator including cost of primer and enamel paint
Holding down of foundation nut & bolt
Labour charges for conveyance of 200mm dia PVC pipes from nearest onloading village to work site as per direction of site Engineer-in-charge.
Labour charges for Laying & fitting 160/200 mm dia PVC pipes as per direction of site Engineer in charge.
Installation of Mono Block Pump Set,on fixed foundation , fitting of 80/100 mm dia G.I.Pipe in Suction side & delivery side with required G.I.Flange, Bend, socket, primary unit, foot valve,N.R.Valve, nut bolt, rubber packing etc., cutting ,threading & welding of G.I.Pipe connecting the same to main pressure P.V.C. pipe line including cost of white lead paint ,cotton tape,M seal ,hickaw blade and other unforseen items as required for fitting works ,earch cutting of river bank , river belt, making Sump pit for dipping of foot valve at required depth for smooth running of Pump set including all transportation of materials etc.& Electrical connection complete as per direction of the site Engineer-in-charge.
Cost and Labour charges for febrication of fitting of Tee outlet.
Cost & labour charges for Road crossing along pipe line
Labour charges for Laying and fitting of 200 MM DIA MS pipe line
Transportation of materials from local market.
Cement punning
Labour charges for fitting of Air release valve
finishing walls with WPC Paint of approved sheade on new work(2coats)
River Bank cutting
Execution of Bi-party agreement with P.P and OLIC.
Monoblock Centrifugal Pumpset of total head of 34 M capable to discharge 1700 LPM, 10 HP / 7.5 KW squirrel cage induction Motor of kriloskr make, fitted with campanion flanges and Cl "F" insulation suitable for operation at 415 Volt + 6 % - 15% , 3 Phase 50 Hz A.C power supply confirming to IS 9079/2002 with ISI mark & guarantee.as per direction of site Engineer in charge.
63 Amp Main Switch
15 H.P Auto Star Delta Control Pennel Starter of sheet Steel enclosure suitable for operation of squirrel cage Induction Motor up to15HP with 20 MP ( AC/3) duly contactor at 415 Volt + 6% - 15% , 3 phase 50 Hz , A.C supply with Over Load Relay range 17 to 24 Amp and No volt coil with electronic timer suitable for operation at voltage range of 300 -440 volt and to provide dependable protection during over load and single phasing as per direction of Engineer-in-charge.
Motor hood cover
Motor base plate
3 Core x 10mm² Insulated ( HD ) armoured Electric Cable with Alluminium conductor for use in 3 phase power system of working voltage up to and including 1100 Volts at 50 Hz confirming to IS 1554 (Pt - 5 ) / 1988 with ISI mark & guarantee.as per direction of site Engineer in charge.
5 KVAR Capacitor
Cost of 2.5mm sqar Flat cable
100mm dia Nominal Bore G.I.Pipe having wall thickness 4.5 mm, Electrical resistence welded of Medium Class confirming to IS 1239( Pt) - 1 / 2004) with latest ammendments screwed at both ends as per IS 554 with socketed at one end and other end protecteted with plastic thread protector.The socket to conformintg to IS-1239(Pt)-II/1992.with latest emmendments with randam length of 4 to 7 mtrs.& should bear ISI satisfavction & manufacturer name/trade mark as per direction of site Engineer in charge.
100 mm dia G.I Bend
100 mm dia G.I Flange
100 mm dia C.I Foot Valve (K/s)
5/8" x 21/2" & 1/2"x2'' M.S. Full threaded Nut Bolt (Heavy Duty)
3 mm ( 1/8") thick Rubber Insertion
100 mm dia C.I N.R Valve
100x100x75 mm dia G.I Tee with plug for priming
100 mm dia Socket
Cost of 25 mm C.I Air release valve with saddle and raiser pipe
Rigid UPVC pipe of 200 mm dia (Cl-I) Ivory grey in colour having specific gravity of 1.4 to 1.46 Gm / CC of straight length of 6 M for portable water supplies confirming to IS 4985 / 2000 of BIS - Amendment - 2 Read with Table - I , of IS specification bearing ISI Mark for working presure of 2.5 Kgf/Cm2 as per latest amendment of ISI 4985 including cost of coupler for plain ended pipes or one end plain & other bell ended. The pipe should be tested by CIPET & each pipe should be clearly & indebile marked ink or Senciled conforming to IS 4985/2000.
200x200x110 mm MS Tee with riser set.
200mmx100mm dia fabricated MS Tail Piece.
200x200x200 mm dia PVC Equal Tee
Solvent cement
200 mm dia End cap
200 mm dia PVC Coupler(Class_II)
Frame for Starter & Main switch
Post delivery CIPET test charges of PVC pipes
Cost of Enargy meter
Schedule B (Electrical Works)
Construction of 3-phase 11 KV line as per REC standard confirming to RE Rules 1956, with 9 meter long PSC pole , 55 sq.mm A.A.A. conductor of , 11 kv “V” Cross-Arm, required Stay-Set at bending point and double Stay at end point with 18 mm G.I. H.T. Stay, with required numbers of 11 kv T&C Disk Insulator and 11 kv Pin-Insulator,providing Coil earthing at each pole , Carping and Padding of Poles, Danger Board at each Pole with Anti-Climbing device etc. including cost of all labours, inspection and commissioning & writing on the Pole as per prescribed colour code, etc. complete as per the detailed scope & estimate & direction of the site engineer in charge .
Construction and erection of 11/0.416 KV 25 KVA Star rated(2 star & above) DP Sub-Station confirming to RE Rule 1956. Mounted on 2.44 mt. long structure, supported in 9 mt long PSC pole, Transformer Hard Channel & top Channel made of 2.8mt. long 100X50X6 mm MS Channel, transformer belting on 2.80mt. long 50X50X5mm M.S.Angle, ( all REC SPN. Std. F-3 ), with all accessories like, 3-pole 11 kv H.G. Fuse (F-5) and A.B. Switches (F-9) both mounted on 2.8 mt. long 75X40X6 mm M.S.Channel and supported by 1.0 mt. long 50X50X5mm M.S.Angle, with 3 nos. 11 kv Lightening Arrestor and Distribution-Box for 25 KVA S/S, mounted on Box (75X40X6 mm)2.5 mt. long, Pipe Earthling (F-2), ), including cost of 95 sq.mm 3.5 core LT Cable ,connecting the supply line with 55 sq. mm AAA Conducter,providing 18 mm G.I H.T Stay as required ,Carping and Padding of Poles, Danger Board at each Pole, Anti-Climbing device etc and all other necessary fittings i.e. required size nuts & bolts, brackets, Cable, Cable Sockets etc. including cost of all labours, transportation, complete with liaison for testing, inspection and commissioning& writing on the Poles as per prescribed colour code& fixing the display Board of required size & painting as per prescribed colour code and writing the salient features,Fencing with barbed wire & iron gate with sand & metal spreading. etc. complete as per the direction of the site engineer in charge ..
3phase 4wire LT line with AB Cable
Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps,nuts & bolts, cable socket etc. including excavation of earth pits 2 Nos of size 1200mm X1200mm X 3200mm for fixing of earthing pipe 2 Nos of size 40mm dia X 3000 mm length with required slotting in pipes & fittings with 40 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work & pannel wiring with 4 Sq. mm PVC copper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge.
Pump chamber wiring
B.Mohan Rao
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_331659.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .