Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-Finance 225 4 DR A K PAUL ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-Finance ok | |
| 2 | L2₹5.4 L+₹32,620 (6.42%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹5.8 L+₹68,192 (13.4%)Rejected-Finance 19 VIVEKANANDA SARANI P O SODEPUR KOLKATA 700110 PS KHARDAH | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700110 | L3 | Rejected-Finance Higher bidder | |
| 4 | Rejected-Technical 221 3 SALT LAKE SECTOR II KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | - | Rejected-Technical Invalid trade License |
Tender Value
Refer Docs
EMD Value
₹14,400
Closing Date
21 Sept 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Paschim Med. Elecl. Div. PWDte
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte. Paschim Medinipur
Supply, Installation, Testing and Commissioning of 20 KVA online U.P.S along with allied E.I work in VRDL Lab. In reference to COVID-19 under Microbiology Department in Midnapore Medical College, Paschim Medinipur.-- SITC of 20KVA UPS.
2020_WBPWD_295711_1
WBPWD/EE/PMED/NIQ-15/e-T /2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Medinipur, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹14,400
1 Oct 2020
9 Sept 2020
23 Sept 2020
9 Sept 2020
21 Sept 2020
9 Sept 2020
120 days
Amount
SITC of 20 KVA online UPS, 3 Phase input and 3 Phase Output a)Topology:- IGBT Based DSP Controlled b)Ratting (KVA/KW):- 20 KVA/18 KW c)Input Voltage:-310--400--415 VAC, VolatgeRange:- 320-480 VAC d)Frequency:- 50 Hz e)Input PF:- 0.99 with IGBT rectifier f)Isolation Transformer:- Inbuild Isolation Transformer should be provided at the Input of the UPS. No external, step up Transformer will be accepted. g) Back feed Protection:-Ups should have back feed protection. h) DC Ripple:- Residual Ripple voltageshould be < 1% i)Charging:- Automatic Boots cum float charging capability with settable float and boots charging voltage and current level and boots charger timer. j)Input Current Distortion:-THDi <=3% k)Output Voltage:- 380--400--415 l)Output Volage Regulation:- Static Variation ± 1%, dyanamic variation ± 3%. m)Output Frequency:- 50 Hz (± 0.1%) n) Output Power Factor:- 0.9 o) Crest Factor:- 3: 1
a)THDi < 1% (linear load), < 5% (non linear load) b)Waveform:- Pure Sine Wave c)Bridge:-Microprocessor based and IGBT Technology d)Overload:- 110 % for 10 minutes, 133% for 1 minute, 150 % for 5 Sec, 103% continuous e)Static By Pass:- 100 % rated static switches with fuse protection f)Over load on Bypass:- 100 % g) Overall Efficiency:- Up to95 % h)Battery Cabinet:-With power coated MS Angle with MS sheet suitable dimension and gage, well air ventilation to ensure the battery optimum life cycle. Using Nyvin cable with proper ratting for interlinks cables and battery input and necessary accessories. i)DC Bus:- Minimum 480 V or above, 60 minuted required (minimum 31200 VAH) Battery. j) Battery make:- Excide/Amaron k) Protection:- Input & Output Over/ Under Voltage, Single Phasing DC - High/ UnderVoltage, Battery Charging Over Current, Output Over load / ShortCircuit /OverTemp. UPS ON on Mains recovery Audio Alarm, Mains Fail, Battery low Pre-alarm, Inverter Trip (l) Metering:- Graphical LCD display for Input & Output - Voltage, Current &Frequency, Battery- Voltage & Current
a) Indications:- Mains- On/Fall/High/Low/ Single Phasing DC- On/ High,Battery- LowPre-alarm/ Low Tip Inverter- On/ Trip/High/Low /OverCurrent b) Switchgear:-MCB/MCCB for Input, Battery, Output & Manual Bypass Switch Termination: Input, Battery, Output & Bypass c) Enclosure:- IP 21 d) Operating Temperature:- 0 to 40 Deg C e) Humidity:- Up to 95 % Rh ( non- Condensing) f) Colling:- Forced Air g) Noise:- < 55dB h) Cold Start : Provided i) Communication: RS 232, RS 485 j) Monitoring Software:-UPS Monitoring Software on Windows XP Platform k) Certification: ISO 9001: 2008, ISO 14001:2004, ISO18001 and OHSAS l) CE Marking: IEC/EN 62040-1-1 IEC/EN 62040-2 (EMC Emission), IEC/EN 62040-3(performance &Design) Warrnty 2 Years incl battery. (Make :- POWERONE/ APC/ EMERSON/ NUMERIC)
Terms and Condition:- 1) The Agency must procure the materials from the manufacturer/ OEM or from their authorized sales and channel so that the standard warranty/ support of the manufacture/ OEM becomes applicable to the products to be delivered and installed by them. 2) Documents that authenticates such procurement from the manufacturer/ OEM or from their authorized sales channel and standard warranty/ support should be send from the e-mail of the manufacturer/ OEM/ authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/ submission of bill. 3) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. 4) Rate should be quotated in including all taxes & GST.
RASH ELECTRICAL WORKS
R D ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .