| Sl No | Description | Qty | Unit | metro electrical services L1 | SI ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | M & L for comprehensive maintenece and servicing of Split type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge.
(Note: Spares parts replaced shall be measured & paid under saperately under relevant items here-in-below) | 135 | Each Job | 700 ₹94,500 Lowest | 1,600 ₹2,16,000 |
| 2.00 | All as per Item No. 1 above, but for Water cooler/Deep freezer/Refrigerator of any type and any capacity | 135 | Each Job | 700 ₹94,500 Lowest | 1,300 ₹1,75,500 |
| 3.00 | Supply only starting capacitor of suitable capacity for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed. | 75 | Each | 140 ₹10,500 Lowest | 300 ₹22,500 |
| 4.00 | Supply only running capacitor of suitable capacity all as specified and directed. | 120 | Each | 280 ₹33,600 Lowest | 800 ₹96,000 |
| 5.00 | Supply only starting relay suitable for water cooler, AC, and refrigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed. | 51 | Each | 240 ₹12,240 Lowest | 280 ₹14,280 |
| 6.00 | Supply Only for over load relay comprising of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in single phase 230 volt all as specified and directed. | 90 | Each | 420 ₹37,800 Lowest | 450 ₹40,500 |
| 7.00 | Supply only themostat switch suitable for Air conditioner, water cooler, deep freezer and refrigerator operated on single phase 230 volts supply all as specified and directed. | 80 | Each | 350 ₹28,000 | 320 ₹25,600 Lowest |
| 8.00 | Supply only drier filter for AC, water cooler and refrigerator. | 40 | Each | 320 ₹12,800 Lowest | 550 ₹22,000 |
| 9.00 | Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed. | 70 | Each | 1,100 ₹77,000 Lowest | 1,550 ₹1,08,500 |
| 10.00Supply Only capillary tubes for the following :- | |||||
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Sept 2025, 6:00 pmClosed
Shri Vikas Tanwar, IDSE, GE (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Pune
REPAIR AND MAINT OF REFRIGERATOR, AC, DESERT COOLER, WATER COOLER AND OTHER COOLING APPLIANCES AT CME PUNE UNDER GE (CME) KHADKI
2025_MES_724302_1
8629/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Khadki
₹50,000
Yes
11 Sept 2025
4 Aug 2025
3 Sept 2025
4 Aug 2025
1 Sept 2025
19 Aug 2025
5 Aug 2025 - 18 Aug 2025
Amount
M & L for comprehensive maintenece and servicing of Split type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge. (Note: Spares parts replaced shall be measured & paid under saperately under relevant items here-in-below)
All as per Item No. 1 above, but for Water cooler/Deep freezer/Refrigerator of any type and any capacity
Supply only starting capacitor of suitable capacity for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed.
Supply only running capacitor of suitable capacity all as specified and directed.
Supply only starting relay suitable for water cooler, AC, and refrigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed.
Supply Only for over load relay comprising of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in single phase 230 volt all as specified and directed.
Supply only themostat switch suitable for Air conditioner, water cooler, deep freezer and refrigerator operated on single phase 230 volts supply all as specified and directed.
Supply only drier filter for AC, water cooler and refrigerator.
Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed.
Supply Only capillary tubes for the following :-
Air Conditioner 1.5 ton /2 ton and Water cooler 40 to 150 ltr
Refrigerator & Deep freezer upto 400 ltr
Supply only indoor fan motor of split type AC of any capacity.
Supply Only Condensor fan motor as per existing make and capacity for the following as under all as specified and directed by Engineer In Charge
Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton
Window type AC of 1.0Ton/1.5Ton/2.0Ton
Water Cooler of 40-80 Ltr and deep freezer upto 400Ltr
Water Cooler of 120-150Ltr
Supply only blower/condensor fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer all as specified and directed.
Supply, install, test & commissioning hermatically sealed new compressor for Split type AC of capacity 1.5TR duly charged with fresh freon gas etc complete all as specified/directed by Engineer-in-Charge including taking down old u/s compressor.
All as per item No.13 above, but for split type AC of capacity 2.0 TR
All as per item No.13 above, but for Window type AC of capacity 1.5TR
All as per item No.13 above, but for Window Type AC of capacity 2.0TR
All as per item No.13 above, but for Water Cooler of capacity 40 to 80Ltr
All as per item No.13 above, but for Water Cooler of capacity 120 to 150Ltr
All as per item No.13 above, but for Refrigerator 165 to 160Ltr Capacity
All as per item No.13 above, but for Refrigerator 286 to 310Ltr Capacity
All as per item No.13 above, but for deep freezer 298 to 310 ltr capacity
M & L for detecting the gas leakage, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldering etc, vacumizing and charging of refrigent gas and commissioning and testing for the 1.5Ton/2.0ton split type/window type AC all as specified and directed by Engineer In Charge
All as per item No. 22 above, but of water cooler, refrigerator & deep freezer of any type and any capacity
Supply and replacement of remote control unit of Split type AC 1.5 ton/2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge
Supply and replacement of Electronic PCB unit for main control panel of Split type/Window type AC of any capacity all as specified and directed.
Supply and replacement of DC inverter Electronic PCB unit for indoor unit main control panel of Split type/Window type AC of any capacity all as specified and directed.
Supply and replacement of DC inverter Electronic PCB unit for outdoor unit main control panel of Split type/Window type AC of any capacity all as specified and directed.
M&L for dismantling of existing unserviceable voltage stabilizer for repairs including replacement of relays , electronic voltage sensor circuits and meter, micro switch , indication light RC fitters and other connected items for making functional as per the entire satisfaction of Engr-in-charge and rewinding of unserviceable transformer with super enamelled copper wire of appropriate size , varnishing assembling and testing complete for following capacities:-
Disconnecting electrical / mechanically and lowering to the ground for repairing / over hauling the desert cooler including replacement of canvas grass / wood wool pads to make it fully functional including replacement of unserviceable/defective spare parts, transportation to and fro, re-installation and testing on completion to the entire satisfaction of Engineer -in - charge Note : Spares replaced will be measured and paid under seperate Item
Supply only water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge.
Supply only fan motor of desert cooler of any capacity including supporting legs , nuts and bolts etc.
Supply only fan blade with bush for desert cooler motor
S & F in replacemrnt of Metal Plug Tops for 2 Pin and earth socket AC Box of capacity 240V, 20 A all as specified and directed
S&F in replacemrnt of connecting sheet metal enclosure with two pin and earth plug and socket complete, with one double pole MCB 20 Amp
Supply and fix in replacemrnt of PVC flexible pipe 25 mm dia as in drain pipe suitable for water cooler outlet
S&F in replacemrnt of Ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore.
S & F in replacemrnt of Push tap Self closing taps of size 15 mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler
Supply and fix in replacemrnt of PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers including taking down old pipe
M & L in replacemrnt of stainless steel waste water tray including welding, polishing, riveting, provision of fixing screws and refixing.
S & F in replacemrnt of Gaskets for top cover for water cooler of any capacity and make as per site requirement.
M & L in replacemrnt of damage cooling coil for refrigerator of capacity 210/300 ltrs
M & L in replacemrnt of damage condensor coil for refrigerator of capacity 210/300 ltrs
Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 300Ltrs
M&L in replacemrnt of wiring for circuit /sub main wiring with earth wire of size 2x 4.0sqmm + 1 x 2.5sqmm of FRLS PVC insulated copper conductor, single core cable in surface drawing in and including PVC casing capping.
M&L in replacemrnt of wiring for circuit /sub main wiring with earth wire of size 2x 2.5sqmm + 1 x 1.5sqmm of FRLS PVC insulated copper conductor, single core cable in surface drawing in and including PVC casing capping.
M&L in replacemrnt of for power point wiring for refrigerator, water cooler, deep freezer with FRLS cable 2.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 2.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc complete all as specified and directed for multipin 15 amps socket outlet flush type on independent board controlled by one switch & making good to disturbed surface of wall etc all as specified and directed.
Material and labour in replacemrnt of for MS cross arms, bracing supports, clamps fabricated out of structural steel such as ISMC, angle iron, flat iron sections including hot galvanised nuts & bolts, washers for single and two pole structure welding, bending cold or hot, drilling holes for bolts, in any shape or size as specified and including of one under coat and finishing coat with aluminium paint over a coat of red oxide primer. Note: Fabrication,welding and transportation is inclusive in the rate itself. Also, including excavation returning, filling, removing (if required) and connected jointing and fabrication work all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 5/8" as specified and directed by E-in-C.
S&F in replacemrnt of copper tubing 1/4" as specified and directed by E-in-C.
S&F in replacemrnt of copper tubing 3/8" as specified and directed by E-in-C.
M&Lin replacemrnt of for copper condensor coil in out door unit of 1.5 ton/2.0 ton Split AC all as specified and directed.
M&L for removal of existing split AC 1.5 ton/2.0 ton and refixing in new location including core cutting in stone wall and gas charging including required gas all as specified and directed by Engr in charge.
SI ENTERPRISES (BID ID -3403356)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .