Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC being lowest bidder | |
| 2 | L2₹49.9 L+₹6.0 L (13.6%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹54.6 L+₹10.7 L (24.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Jul 2022, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF LT CABLES LT DISTRIBUTION PANEL INCLUDING OTHER CONNECTED ACCESSORIES AT SECTOR A B UNDER AGE EMII OF GE 865 EWS
2022_MES_534960_1
865/EWS(NIT-61)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹80,000
Yes
20 Sept 2022
30 Jun 2022
1 Aug 2022
30 Jun 2022
29 Jul 2022
14 Jul 2022
Amount
Supply and fixing in replacement of Pin type, porcelin, vitreour, white, brown or green insulator, size 100 mm height, 65 mm dia for 1100 volts grade, conforming to IS: 7321-1931, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of shackle type insulator, porcelain, vitreous 100 mm high and 115 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 1100 volts complete all as spd and as directed by Engineer-in-Charge.
Supply and fixing in replacement of off load changeover switch AC 230, capacity 100 Amps, 4 pole in sheet metal enclosure, 415 volt, sidet handle operated, and all connected acessories cat No IHCFFEC0100 Make-Havells or equivalant as per PS complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of off load changeover switch AC 230, capacity 63 Amps, 4 pole in sheet metal enclosure, 415 volt, sidet handle operated, and all connected acessories cat No IHCFFEC0063 Make-Havells or equivalant as per PS complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below ground level connected to and including GI strip 25x4 mm as earthing leads by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore light grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc including taking out of old u/s earthing set, complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order (iii) Item includes the cost of Charcoal and commercial salt
Excavating in trenches not exceeding 1.5 m wide and not exc. 1.5 mtr in depth and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
Supply and spreading sand for cusioning of electric cable 80 cm below cable and 15 cm above cable including watering and well ramming in layer complete all as specified by Engr-in-Charge.
Supply and laid of facetory made, machine pressed, Un-reinforced, precast concrete cable cover class LV type-2 flat size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-Charge.
Supply and laying of tubes light grade of size 40 mm bore galvanised with all fittings and fixed complete to walls or laid in trenches complete all as specified and as directed by Engr-in-Charge.
Supply and laying of tubes light grade of size 50 mm bore galvanised with all fittings and fixed complete to walls or laid in trenches complete all as specified and as directed by Engr-in-Charge.
Returning filling, spreading, levelling , watering and well ramming in layers not exc 25 cm complete all as specified by Engr-in-Charge .
Removing excavated material not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 10 sqmm 2 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 10 sqmm 4 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 16 sqmm 4 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 25 sqmm 4 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 35 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 50 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 70 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 95 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 120 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 185 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 240 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply, laying, installation and commissioning in replacement of LT underground cable ISI marked XLPE insulated heavy duty electric cable armoured and PVC sheathed heavy duty 1100 volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, ducts and fixing with fixing material on pole, wall complete of 400 sqmm 3.5 core complete all as specified and as directed by Engr-in-Charge. Make : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of ON Load Change over (front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 200 Amps with connecting acessories complete all as specified and directed by Engr in Charge. : Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make :As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and replacement of Off Load Change over (side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make : As per PS
Supply and fix in replacement of indicator lamp LED type (Red, Yellow, Green) moulded single piece suitable for LT panels complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of PVC Spacer 2/4 way for LT over head line 1100 Volt with necessary nut and bolts etc complete all as specified and directed by Engr-in-Charge.
Supplyand fixing cable route indicator made out of cast iron and embedded LT cable on the plate of size 80 mm dia and 5 mm thick, grouting luggs with PCC 1:2:4 in size of 150 x150 x 150 mm including excavation and making good surfaces complete all as specified and directed by Engr-in-Charge.
Material and labour for two coats of synthetic enemal smoke grey paint of LT panels including taking down exposed surfaces with emery paper and brush complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of LT pole including cleaning of exposed surfaces with brush and emery paper including paintingwith yellow and black colour with unterminate layer of each colour paint upto 1.50 mtr complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of aluminum thimble of size 35/50/70/95 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of aluminum thimble of size 120/150/185/240/300/400 Sqmm complete all as specified and directed by Engr-in-Charge.
Material and labour for synthetic insulating matt for Electrical instrument of size 2M x 1M x 10 mm thick complete all as specified and directed by Engr-in-Charge,
Material and labour for Plain cement concrete 1:4:8 type D2 using 40 mm graded aggregate as in base for foundation complete all as specified and directed by Engr-in-Charge.
Material and labour for plain Cement concrete in filling and mass concrete/ Coping of Poles and PCC for road crossings etc all as directed , type C-2 1:3:6 (20 mm graded aggregate) complete all as specified and directed by Engr-in-Charge.
Dismantling of LT/HT poles and erection of same pole at suitable directed location including dismantling of ACSR conductors, cross arms and other related acessories including stay assembly and restringing/Restretching aluminum conductor/GI wire on HT over head lines including necessary binding wire with, conections of incoming and out going cables complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing in replacement of ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre to centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, etc complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing in replacement of cross arms bracing supports clamps, back plates fabricated from steel section made out of Fe-410 structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminum paint over one primer coat, complete all as specified and directed by Engr-in-Charge.
Material and labour for fixing in replacement of cable end kit for 11KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as directed by Engr-in-Charge.
Material and labour for fixing in replacement of cable end kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as directed by Engr-in-Charge.
Material and labour for fixing in replacement of stay assembly complete with stay plate bow, stay rod of dia 16 mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR Part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 63 Amps, 415 V, 4 pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 100 Amps, 415 V, 4 pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 125 Amps, 415 V, 4 pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 160 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 200 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 630 Amps current carrying capacity 50 KA, 3 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 630 Amps current carrying capacity 50 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 500 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 400 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with terminal and adjustable magnetic setting complete all as specified and directed by Engr-in-Charge.
SUMEET TRADING CORPORATION
darshan kumar gandhi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .