Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST L1 | |
| 2 | L2₹22.9 L+₹2.2 L (10.8%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.7 L+₹9.0 L (43.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O56 APO PIN 913970
REPAIR AND MAINT OF WATER SUPPLY LINES INCL MAIN PIPE LINE, VALVES, VALVE CHAMBERS, WATER HEATING PLANT, RO AND INTERNAL WIRING AND CONNECTED ITEMS INCL CLEANING OF OHT AND UG SUMPS AT MANASBAL UNDER GE 970 EWS
2022_MES_569901_1
GE 970 EWS-61/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹70,000
Yes
7 Mar 2023
19 Dec 2022
19 Jan 2023
19 Dec 2022
17 Jan 2023
3 Jan 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc
Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH) drawn through and including PVC concealed conduit 19/20 mm bore (ISI marked) and accessories (concealed in wall & surface in ceiling complete including cutting ,chases & making good disturbed surfaces), terminated in and including pressed steel terminal boxes with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan/exhaust point / bell push point controlled by one way switch 5 Amps and/or through regulator complete all as specified and directed. complete all as specified.
All as per description of srl item No 2 here-in-before but socket out let 3 pin, 5 Amp on same board with other switch.
All as per description of srl item No 2 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch.
All as per description of srl item No 2 here in before but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 1.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board.
Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH) drawn through and including PVC casing & caping and accessories on wall & surface/ceiling complete terminated in and including PVC gang box fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed. complete all as specified.
All as per description of srl item No 6 here-in-before but socket out let 3 pin, 5 Amp on same board with other switch.
All as per description of srl item No 6 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch.
All as per description of srl item No 6 here in before but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 1.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board.
Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200Amp rated bus bar complete all as specified and directed including taking down old unserviceable DB of any description.
Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN - 12 Way complete all as specified and directed including taking down old unserviceable DB of any description.
Supply and fixing in repairs two pin and earth metal plug and socket complete with one single pole MCB 20 Amp, 240Volts complete all as specified and directed.
Supply and fix in repair MCB TPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fix in repair MCB SPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fix in repair MCB SPN 40 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fix in repair MCB SPN 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fix in repair MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in repairs Switch piano, flush type 5 Amps, 240 V One Way complete all as specified and directed.
Supply and fixing in repairs Switch piano, flush type 15 Amps, 240 V One Way complete all as specified and directed.
Supply and fixing in repairs socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed.
Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed.
Supply and fixing in repairs switch socket combination out let 5A/15 Amps, 5 in 1 flush type complete all as specified and directed.
Supply and fixing in repairs Ceiling Rose 3 terminal size 50 x 65 mm surface type complete all as specified and directed.
Supply and fixing in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed.
Supply and fixing in repairs lamp holder battan / angular type complete all as specified and directed suitable for 3 to 7 watt LED lamp
S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 3 watt complete all as specified and as directed
S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 5 watt complete all as specified and as directed
S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 7 watt complete all as specified and as directed
Supply and fix in repairs 1X18 watt 4 ft long LED Batten housing with white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.95 with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed. make : Bajaj or equivalent in : Havells /Philips/CG. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fix in repairs Fluorescent tube light fitting, LED batten with aluminium housing provided for efficient heat dissipation wirh polycarbonate diffuser and integrated electronic driver, 1x 10 watts 2 feet light fitting with white acrylic cover along with LED lamp white colour complete and connecteing electrically to ceiling rose using PVC insulated and overall sheated flexible copper conductor of size 0.75 Sqmm 3 core fixed complete all as specified and directed. Make : Bajaj or quivalent in : Havells /Philips/CG Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
M&L for sub main wiring in repairs for power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit.
M&L for Sub Main wiring in repairs complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 6 Sqmm single run for earthing including taking down the old submain wiring all as directed by Engineer in Charge. Notes:- (i) Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC conduit shall be measured as one unit.
Supply and fixing in repairs decorative garden light (landscape lighting) made up of high grade unbreakable polycarbonate materials of capacity 9W LED complete all as specified and directed. Make : Bajaj or equivalent/Havells/CROMPTON. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) The contractor should include the rates for PCC as required and nut bolts for fixing the light in the quotated rate.
Material and labour in repairs for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of theplate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed.
Supply and fixing in repairs square LED panel light filtting ceiling /recess mounting type with slim, compact, aluminium die cast edge lift panel completer with opal diffuser and electronic driver inbuilt of capacity18 watt complete all as specified and directed. Make : Havells or equivalent in Bajaj/Philips. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in repairs decorative wall mounting LED light fitting of capacity 9 watts including lamp made up of high grade engineering plastic material and suitable for B2 LED lamp base complete all as specified and directed by Engr-in-Charge. Make- Havells or equivalent in Bajaj/Philips.
BLANK
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in soft/loose soil for foundation, etc, or for shafts, wells, drain pipes n.exc 10sqm on plan and getting out, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 20mm, complete all as specified and directed.
All as per item No. 41 above but 25mm bore.
All as per item No. 41 above but 40mm bore.
All as per item No. 41 above but 50mm bore.
Laying only GI water mains after removal of scalling, cleaning and flushing etc including supply and fixing of new fittings for 20mm bore pipe, complete all as specified and directed.
All as per item No. 45 above but 25 mm bore.
All as per item No. 45 above but 40mm bore.
All as per item No. 45 above but 50mm bore.
3- layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete of size outer dia 63 mm, including fittings complete all as specified and directed.
3- layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete of size outer dia 32 mm, including fittings complete all as specified and directed.
3- layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete of size outer dia 25 mm, including fittings
3- layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete of size outer dia 20 mm, including fittings complete all as specified and directed.
Supply and fixing in repair PPR gate valve (brass insert) of size 20 mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair PPR gate valve (brass insert) of size 25 mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair PPR gate valve (brass insert) of size 32 mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair PPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair Ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fix of size 20 mm complete all as specified and directed.
Supply and fixing in repair Ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fix of size 25 mm complete all as specified and directed.
Supply and fixing in repair cast iron sluice valve of 80mm dia with end flanged with iron wheel handle for clockwise closing brass spindle heavy duty PN-1.6 class. including gaskit joint nut, bolts & washers all as requirement of site complete all as specified and directed.
All as per item No 59 above but 100mm bore --ditto--
All as per item No 59 above but 150mm bore--ditto--
Supply and fixing in replacement of joints for spigot and socket CI pipe with run lead joints for 150mm bore complete all as specified and directed
Supply and fixing in replacement of joints for spigot and socket CI pipe with run lead joints for 100mm bore complete all as specified and directed
Supply and fixing in replacement of joints for spigot and socket CI pipe with run lead joints includuing for 80mm bore complete all as specified and directed
Taking up/down GI water mains (incl all fittings) with flange ends and incl nuts, bolts etc for repair/maintenance of submersible pump set and cleaning of column pipe etc complete of 80/100 mm bore after disconnecting necessary electrical/water connection and including arrangement for tripod, chain pulley and other tools and plants and safety equipments as required at site and necessary cleaning to entire length of pipe both inside and outside and reassembling and lowering in same position and testing complete all as specified and directed. Note : Column pipe of 100 mm dia if found deteriorated shall be replaced and paid separately under relevant item of schedule.
Supply and laying in repair 100 mm bore GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), complete all as specified and directed.
Supply and laying in repair 150 mm bore GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), complete all as specified and directed
Supply & fix in repair 250 A 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specifeid and directed.
Supply & fix in repair 250 A 3 pole MCCB, 36 KA , 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.
Supply & fix in repair 160 A, 4 pole, MCCB, 36 KA , 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.
Supply & Laying XLPE Cable, insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation tape with and including taking out old UG cable and deposited to MES store yard complete all as directed and specified.
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 25 sqmm 4 core including necessary cable lugs, glands, insulation tape with and including taking out old UG cable and deposited to MES store yard complete all as directed and specified.
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape with and including taking out old UG cable and deposited to MES store yard complete all as directed and specified.
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape with and including taking out old UG cable and deposited to MES store yard complete all as directed and specified.
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : punned thickness shall be measured for payment purpose
Supply and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, of size 300mmx 150mm x 40mm complete all as specified and directed.
Supply and fixing in repair gun metal gate valve of size 20mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair gun metal gate valve of size 25mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair gun metal gate valve of size 40mm dia including connection and testing complete all as specified and directed.
Supply and fixing in repair gun metal globe or gate valve of size 50mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Lagging on pipes of internal dia 20 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs including taking down old, complete all as specified and directed.
All as per item No. 81 above but 25 mm bore tubing.
All as per item No. 81 above but 40mm bore tubing.
All as per item No. 81 above but for 50mm bore tubing.
Dismantling old unsv conventional earth pit including electrode plate/pipe from position and material and labour for maintenace free modern marconite® conductive concrete based technology earthing system in same or different place where directed with copper earth electrode of suitable size including back fill compound and other accessories as required and recommended by OEM and connecting with copper strip of size 25x3 mm in position (connecting upto 7.5 mtr length max) complete all as specified and as directed and having following specifications :- a) Fixed Carbon 98.5 % b) Ash, Volatile and Water 1.5 % c) Sulphur Content 1.5 % Maximum d) Size Grading (Approx) - 10% below 0.10 mm, 5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm (e) Thermal Stability Between (-) 10% and (+) 60% ambient temperature (f) Ultra Low Resistivity (g) Versatile - shall be suitable for all type of soil and climate (h) Consistent Performance (i) Chemically Inert (j) Non-corrosive (k) Maintenance free and life span.
Dismantling and taking down old unserviceable LT panel board from it's existing position after isolating electric supply and supply, install, tsting and commissioning of CPRI Approved LT panel board, outddoor, cubical, dust and vermin proof made out of 3.0 mm thick MS sheet with front and back door openable type fitted with nuts, bolts and washers fitted with knobs and hinges and air vents incl painting with two coats of enamelled paint over a coat of red oxide primer, suitable for 415 Volt, 50 Hz, 3 phase, 4 wire suitable for and incl the following :-
a).Onload changeover switch 4P 250 amps - 01 (Incoming)
b). MCCB TP 100 Amps,25 KA - 04 Nos (outgoing)
c ). MCB TP 32 Amps,25 KA - 04) (outgoing)
f). LED indicator lamp -03 Nos
g). Aluminium bus bar chamber of capacity with bub bar 400 Amps TPN with bub-bar insulator etc in clour coding
h). Internal wiring with suitable size single core copper conductor cable of Red,Yellow, Blue and black colour including lugs, Ferrule, tag etc
Disconnectiong existing defective electric motor of any make 30 HP from electric mains isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge and carry out minor repairs at site or transporting to workshop and back, reassembling the motor after repair, refixing in position reconnecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of defecting parts shall be measured and paid separately as S&F here after. (b) In case of major repairs not possible at site, the motor shall be shifted to Civil workshop, and cost of shifting to wksp and back to site included in the rates.
Taking out old unserviceable/burnt copper winding of motors capacity 30 HP (defective motor taken out in item above) and material and labour for rewinding of electric motor of capacity 30 HP with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge, complete all as specified and as directed.
Disconnectiong existing defective electric motor of any make 17.5 HP from electric mains isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge and carry out minor repairs at site or transporting to workshop and back, reassembling the motor after repair, refixing in position reconnecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed. Note :- (a) Replacement of defecting parts shall be measured and paid separately as S&F here after. (b) In case of major repairs not possible at site, the motor shall be shifted to Civil workshop, and cost of shifting to wksp and back to site included in the rates.
Taking out old unserviceable/burnt copper winding of motors capacity 17.5 HP (defective motor taken out in item above) and material and labour for rewinding of electric motor of capacity 17 HP with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge, complete all as specified and as directed.
Supply and fixing in replacement Direct On Line starter for 15/17.5 HP submersible pump 3 Phase 415 volts, complete all as specified and directed. Make: Havell's/L&T/Siemens.
Supply and fixing in replacement Direct On Line starter for 30 HP submersible pump 3 Phase 415 volts, complete all as specified and directed. Make: Havell's/L&T/Siemens.
Supply and fixing in replacement Direct On Line starter for 7.5/10 HP submersible pump 3 Phase 415 volts, complete all as specified and directed. Make: Havell's/L&T/Siemens.
Taking out old unserviceable/burnt copper winding of motors capacity 7.5/10 HP and material and labour for rewinding of electric motor of capacity 17 HP with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge, complete all as specified and as directed.
Supply, connecting, testing and commissioning in replacement of unsv submersible cable with copper conductor, stranded of size 10 sqmm 3 core, complete all as specified and as directed.
Supply and fixing in replacement single phase preventor, complete all as specified and directed.
Construction/repair of old existing Valve pit chamber of size 90cm x 90cm x 90cm internal dimension brick/stone construction including all excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exc 50m and depositing were directed, PCC foundation of the mix (1:2:4), type D-2, brick masonry including plastering, rendering 12mm thick in cement mortar (1:4) internally finished even and fair and flush pointing externally as the work proceeds in same mortar and suitable size angle frame with mild steel angle iron 40X40x6mm, MS sheet cover 3.15mm thick with handle and locking arrangements and painting all steel surfaces with two coat of synethic enamelled paint over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint as approved, complete all as specified and directed.
Cleaning of underground water sump by pumping out water below suction level, removing all internal deposited sludge by non clogging submersible pump, cleaning the surface of the sump using wire brushes and other scraping tools to remove dirt and scales to make it free from all deposits, washing the sump with high pressure compressor nozzle thoroughly and removing dirty water from the pump to make it clean including repair to the internal surfaces by plastering with cement mortar 1:3,15mm thick and providing fillers at cracks to prevent any seepage of water including disinfecting the sump surfaces, complete Painting one coat of water proof paint all as specified and directed of from 50000 gallons capacity. (Note:- the work of cleaning and disinfection will be carried out by expert in the field of the work. the work will be carried out in such a way that the water supply is not interupted; necessary bypass arrangement to be done). (Note : For every six months cleaning will be carried out and will be measured as one unit)
Cleaning of Overhead reservoir by draining out water below supply level, removing all internal sludge by washing. Cleaning the surface of the reservoir using wire brushes and other scraping tools to remove dirt and scale to make it free from deposits. Washing the reservoir with high pressure compressor nozzle thoroughly and removing dirty water from the tank to make it clean. Repair to internal surfaces by plastering and providing fillers at cracks to prevent any sepage of water. Disinfecting the sump surface using disinfectent complete all as specified and directed for 50000 gallons capacity (Note:- The work of cleaning and disinfection will be carried out by expert in the field of the work. The work is to be carried out in such a way that the water supply is not disrupted.) (Note : For every six months cleaning will be carried out and will be measured as one unit)
Supply & spraying Bleaching powder of superior quality with latest lot and test certificate from authorized laboratory with min 30% active chlorine (in 25 Kg bags) in and around water supply installations to maintain hygenic enviornment/prevent algae growth at required interval or as and when directed. Make: Nishat/Shriram/Modi.
Supply only Sodium Hypochloride/Calcium hypochloride in granular form as disinfectant suitable for mixing in drinking water and safe for human consumption as per norms complete duly approved from appropiate auth all as specified and directed. make as approved by GE.
Repair/maintenace of kero based water heating plant of capacity 250/500 ltrs
Dismantling the complete fuel injector pump of water heating plant of various makes and capacity upto 500 ltrs/hour, transporting to trade workshop for repairs and complete servicing and refixing the same after satisfactory repairs, reinstallation, testing and commissioning complete all as specified and directed.
Material and labour for Calibration of fuel injector pump of water heating plant of various capacity upto 500 ltrs, on work bench for fine spray and machining work for proper working complete all as specified and directed.
Supply and fixing in replacement nozzle of hot water plant as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement pressure meter suitable for hot water generator as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement fuel filter suitable for hot water generator as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement solenoid switch for hot water generator as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement burner gasket suitable for hot water generator as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement digital type electronic temprature gauge with thermostat control relay suitable for upto 2,00,000 K Cal/hr capacity hot water generator as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement photo ignition transformer suitable for hot water generator/plant as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement fire proof current lead suitable for hot water generator/plant as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement indicator assembly, complete all as specified and directed.
Supply and fixing in replacement bimetallic overload relay 4.0 - 6.5 Amps type ML, complete all as specified and directed.
Supply and fixing in replacement electromagnetic rod combined with positive/ negative terminals suitable for hot water generator of any capacity as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement photo sensor suitable for hot water generator/plant as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement USB relay box incl sequence meter suitable for hot water plant as per existing size and testing after repairs, complete all as specified and directed.
Supply and fixing in replacement Diesel/fuel pipe with internal and outer threads suitable for hot water generator/plant as per existing size and testing after repairs, complete all as specified and directed.
Dismantling fuel tank of water heating plant, servicing, de-carboning of complete water plant and reassembling the same after cleaning properly by removing all deposited particles, dust, carbon etc, complete all as specified and directed.
Disconnecting and taking out burnt hot water plant blower motor, transporting to workshop, dismantling carefully, cutting out burnt windings, cleaning the slots and rewinding with super emamelled copper winding wire of appropriate gauge & weight incl all insulating materials, varnishing, drying, heating etc and incl replacement of ball bearings as per existing, reassembling and refixing at original site and testing, complete all as specified and directed.
Repair/maintenace of Reverse Osmosis Plants
Periodical repair/maintenance (once in every three months) of RO plants of various capacities installed at Manasbal Garrison as under :-
(a) 01 x 60 LPH RO plant (Make : Sathya Sai Aquapura)
(b) 02 x 100 LPH RO plant (Make : Sathya Sai Aquapura)
(c) 02 x 150 LPH RO plant (Make : Sathya Sai Aquapura)
Note : The repair/maintenance work shall consisting of following major works during periodical maintenance/repair work and cost of the same shall include in each job:-
(i) Replacement of pre filter (01 for each) RO plants
(ii) Replacement of (10 & 5 micron) filter (02 for each) RO plant
(iii) Replacement of pre bowl filter (01 for each) RO plants
(iv) Checking and adjusting TDS level to desired standard or as directed.
(v) Replacement of carbon filters once in a year for each RO
(vi) Replacement booster pump once in a year for each RO
(vii) Replacement of low pressure/limit switch for each RO once in a year
Collecting sample of raw/treated water from borewell/UG sump and carrying to laboratry for bacteriological test and submission of analysis report to department for further action complete all as specified and directed. Note : Sample shall be collected once in a quarter and cost of lab test including transportation of sample shall be included in quoted rate.
M/S Noor Mohammad Shalla
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .