| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bid | |
| 2 | L2₹23.0 L+₹1.5 L (6.78%)Rejected-AOC KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L2 | Rejected-AOC Being higher than L1 bid | |
| 3 | L3₹24.0 L+₹2.4 L (11.1%)Rejected-AOC PO VIKRAMKHAND ROAD LANE NO 05 HOUSE NO 16 ASSAM 788007 | CACHAR | ASSAM | 788007 | L3 | Rejected-AOC Being higher than L1 bid |
Tender Value
Refer Docs
EMD Value
₹40,800
Closing Date
6 Mar 2021, 6:00 pmClosed
GARRISON ENGINEER SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
ROVN OF RETAINING WALL AND SPECIAL REPAIRS TO BLDG NO T-408 AT VAIRENGTE UNDER GE SILCHAR
2020_MES_407287_3
8617/E8
Open Tender
Civil Works
Item Wise
180 days
VAIRENGTE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹40,800
Yes
12 Mar 2021
18 Feb 2021
8 Mar 2021
18 Feb 2021
6 Mar 2021
22 Feb 2021
Amount
PART-I (B/R WORKS) Taking down Shutters of any description not exceeding 1 sqm for each complete all as specified and directed.
Taking down of shutter any description, exceeding 1 Sqm and not exceeding 2 sqm each complete all as specified and directed.
Taking down cement plaster on brick/concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Taking down of GI pipe 20mm bore including all fittings complete all as specified and directed.
Taking down of GI pipe 15mm bore including all fittings complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness as in roof coverings, chajja, wall clading and the like complete all as specified and directed
Dismantling timber scantlings 40 sqcm and over in section, in any position in unframed work complete all as specified and directed
All as per item No. 9 above but as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section as in unframed workd complete all as specified and directed
Dismantling boarding, any description, fixed in any position with nails as in ceiling complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed
Dismnatling of wall and ceiling boards (fibre, plup, insulation boards etc) any thickness including cover fillets complete all as specified and directed.
Dismnatling of Asbestos cement (corrugated, semi corrugated etc sheets in roof coverings complete all as specified and directed.
Demolition of reed, lathing single or double including battens and plaster or chicken wire lathing complete all as specified and directed.
Demolition and braking up AC/CI/PVC drain pipes 50 to 100 mm dia set in cement mortar or fixed in any position and taking out of trenches if required omplete all as specified and directed.
Material and labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement laid in panels and joints filled with bituminous 1 part and 3 part of sand complete all as specified and directed.
M&L Plain cement concrete 1:2:4 type B-1, (using 20 mm graded stone aggregate) as in bed blocks, coping, cills, steps, kneelers, bed plates, holdfast blocks , plates, apex stones kerbs benching and similar work including necessary form work complete all as specified and directed.
M & L for Reinforced cement concrete nominal Mix 1:1.5:3 using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L Reinforced cement concrete nominal Mix 1:1.5:3 using 20 mm graded aggregate in columns, pilars, piers, posts and struts complete all as specified and directed.
M&L RCC nominal Mix 1:1:5:3 using 20 mm graded aggregate in beams, cantilevers, bressummers, lintels over 1.50 mtr span complete all as specified and directed.
Rough excavating in n exc 1.5 mtr in depth getting out in soft / loose soil complete all as specified and directed.
Excavation over areas, n exc 1.5m deep and and getting out in soft / loose soil complete all as specified and directed.
M&L for Hand packing boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
Returning filling in incl watering, ramming in layers n.exc. 25cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50m and depositing where directed at level n.exc. 1.50m above the starting point complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface in soft/loose soil complete all as specified and directed
Material and labour for use and waste of form work to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for rough finished flat surface of concrete complete all as specified and directed.
Material and labour for use and waste of form work to sides of columns, pillars, posts, struts, piers and stanchions, rectangular or square for rough finished flat surfaces of concrete complete all as specified and directed.
Material and labour for use and waste of formwork to edges of rough finished concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and directed.
M&L for RCC nominal Mix 1:1:5:3, type B-1, using 20 mm graded aggregate as in cill band and similar items complete all as specified and directed.
Material and labour for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished flat surfaces of concrete complete all as specified and directed.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified and directed
All as per item No. 35 above but 6mm to 8 mm dia complete all as specified and directed
All as per item No. 35 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed
Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-210 complete all as specified and directed.
Supply and fix bands, straps, clamps, hold fasts, cleats & small articles, supports or stays for rainwater, ventilating pipes, including bolts etc conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F Wire netting of stainless steel wire 1.4mm dia ( Size of mesh in 25 mm) fixed with tinned tacks of stainless steel wire staples complete all as specified and directed.
Supply & filling of 40 mm graded coarse aggregate around weep holes complete all as specified and directed.
S&F Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., not exc. 1.5 m high from base using soil obtained from excavation complete all as specified and directed.
S&F Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., exc. 1.5 m high but not exc. 1.5 m high from base using soil obtained from excavation complete all as specified and directed.
S&F Mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each exc 22.5 cm but n.exc 30 cm long, dia 11 to 15mm necessary fitting complete all as specified and directed.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Rolled Mild Steel Fe 410 -W (Gde- E- 250) quality- A in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F for Pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvaume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, hip valley gutters , drip and straight flashings with grade of zinc coating 275 ( Length & girth as fixed) , fixed with self tapping screws complete all as specified and directed.
S&F MS Plates (plain or chequered) cut to required size, forming holes to receive holding down bolt and welded to tubular/square hollow section truss at both ends complete all as specified and directed.
M & L for brickwork with subclass 'B' or locally available best quality old size bricks, straight or curved on plan exceeding 6 mtr mean raduis, built in CM (1:6) complete all as specified and directed.
M & L for brickwork with subclass 'B' or locally available best quality old size bricks, straight or curved on plan exceeding 6 mtr mean raduis, built in CM (1:4) as half brick thick wall complete all as specified and directed.
Material and labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces finished even and fair complete all as specified and directed.
M&L rendering 15 mm thick cement plaster in two layer ( first layer 10 cm thick in CM 1:4 and second layer of 5 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement) finished even and fair complete all as specified and directed. Note -WPC shall be measured and paid separetly.
M&L for rendering 15mm thick cement plaster in CM 1:4, finished the surface even and fair complete all as specified and directed.
Material and labour for 15mm thick screed bed or bedding layers of (1:6) cement mortar for floor finishes complete all as specified and directed.
Material and labour for 10mm thick screed bed or bedding layers in cm (1:4) for vertical faces of walls complete all as specified and directed.
M & L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles complete all as specified and directed.
M & L for coloured glazed ceramic tiles (300x200) 7mm thick on vertical surface such as skirting, dados, risers etc. set and jointed in neat cement slurry and pointed in coloured cement or pigment to match colour of tiles complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
Supply and fixing / pre-painted 4 mm thick HPSC (High Pressure Steam Cured) non asbestos fiber cement board with design surface as in false ceiling with powder coated GI / aluminimum snap grid / section of size 600 mm x 600 mm fixed to wall hanging from soffits / trusses using adjustable supporting hanger comprising of 2 mm dia wire 'J' type hook, nuts, bolts, holding down clips with GI/ aluminimum section of size 36.5 mm x 25 mm x 1.4 mm (Main Tee) and 23.5 mm x 26.4 x 1.4 mm (cross tee) and walll angle of size 25 mm x 25 mm x 1.4 mm complete all as specified and directed. Make: Everest or equivalent make as approved by GE.
Supply and fix second class hard wood, 35 mm thick, plain framed panel shutter (any numbers of panel) with panels of timber flat on both sides (feather edged) or 12 mm thick veneered particle board medium density fitted to chowkats or frames complete all as specified and directed.
S&F 2nd class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc,sizes of members of shutters as specified in SSR part I, Section 8, clause 8.24 (a), fitted to chowkat etc complete all as specifed and directed
S&F 2nd class hard wood, 30 mm thick, glazed and skeleton shutter, open rebated and prepared to receive glass, gauge etc divided in to squares, with plain chamfered or rounded, mitered and rebated stiles and rails (without sash bars) sizes of members of shutters as specified in SSR part I, Section 8, Clause No 8.24 (b) and fitted to chowkat etc complete all as specifed and directed
S & F for Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
Supply and fix Factory Made Solid Panel PVC Door Shutter, 30mm thick (stiles) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat strips of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, and fixed in the frame at site all as per specification & drawing complete all as specified and directed.
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty or fixed with wooden / PVC beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
S&F 100mm long mild steel butt hinges cold rolled medium weight (ISI Marked ) complete all as specified and directed.
S&F 75 mm long mild steel butt hinges cold rolled medium weight (ISI Marked ) complete all as specified and directed.
S&F Aluminium handle cast type anodise of 150 mm size complete all as specified and directed.
S&F Aluminium handle cast type anodise of 100 mm size complete all as specified and directed.
S&F 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 100mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed complete all as specified and directed.
Supply and fix for 300mm Aluminimum alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F for 20mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor or trenches complete all as specified and directed.
Fixing only old steel tubing of 20mm bore and connections in new or old position (walls, ceiling, floors, etc) including cleaning or returning the old screw threads as required complete all as specified Note : Serviceable steel tube obtained from taking down shall be reused.
S&F for 15mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor or trenches complete all as specified and directed.
Fixing only old steel tubing of 15mm bore and connections in new or old position (walls, ceiling, floors, etc) including cleaning or returning the old screw threads as required complete all as specified & directed Note : Serviceable steel tube obtained from taking down shall be reused.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts), Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel cromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs vitreous china wash basin, white flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand including chromium plated waste coupling & waste pipe of 32 mm dia complete all as specified and directed.
Supply and fix in repairs PVC 10 ltrs capacity valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe of polythylene of low or high density complete all as specified and directed.
S&F in repairs for 15 mm bore Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, fancy handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed.
S&F 15mm bore Bib taps chromium plated cast copper alloy, screwed down, fancy type, screwed for iron pipe or for brass ferrule and fixed in repair complete all as specified and directed.
S&F for PVC connection 15mm dia and 450mm long with PTMT nuts fixed in repair complete all as specified and directed.
S&F15mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe fixed in repair complete all as specified and directed.
S&F Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats fixed in repair complete all as specified and directed.
S&F soap dish, chromium plated standard quality of suitable size fixed to wall with chromium plated brass screws fixed in repair complete all as specified and directed.
S&F in repairs 100 mm dia CP shower rose with arm 15mm dia and 195 mm long with bend of 45 degrees with flange complete all as specified and directed.
S&F 110mm bore PVC pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls with suitable size of MS clamps & nuts-bolts fixed in repair complete all as specified and directed.
S&F 75mm bore PVC pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls in repair complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
S&F PVC (SWR) reducers T equal or unequal 110 to 75mm dia complete all as specified and directed.
M&L for Grating doom 125mm dia with waste hole of PTMT fixed in repair (minimum weight 40gms) complete all as specified and directed.
M&L for two coats synthetic enamel paint over one coat of red oxide primer on new iron surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surface complete all as specified and directed.
M&L for applying two coats of external acrylic emulsion (anti fungal) paint over one coat of alkali registant primer as per manufacturer instructions including preparation of newly plastered surfaces of wall complete all as specified and directed.
Preparation of new or untreated surfaces of wood or wood based surfaces of any description exc.10 cm. in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Material and labour for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer all as specified and directed.
PART-II (E/M WORKS) Taking down carefully copper/aluminum existing point wiring (light/fan/socket or power points) complete incl wooden battens/casing capping or conduit etc (without disturbing existing fittings point wiring etc) and all connected fittings such as switch, socket, ceiling rose, lamp holder, brackets ceiling fittings, bulk head fittings and fan regulator etc and making good to disturbed surfaces of wall floor etc complete all as specified and directed.
Dismantling of old unserviceable main switches DBs, MCB enclosures, electric meter, PVC rectangular blocks etc and keeping in safe custody either for reuse or for disposal Including making good to the disturbed surface of wall complete all as specified and directed.
M&L for Point wiring using FRLSH PVC insulated unsheathed multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed multi stranded copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , PVC box of suitable size etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc for one light/fan/bell point complete all as specified and directed.
All as per Srl item No 105 above but for One 5 pin 5 Amp switch socket out let point on an independent board.
All as per Srl item No 105 above but for One 5 pin 5 Amp socket out let point controlled by one switch on same board.
All as per item No. 105 above but for one 15 Amp 5/6 Pin switch socket outlet independent with 2.5 Sqmm FRLSH unsheathed copper conductor single core multistranded complete all as specified and directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
Supply and fix Bell Push flush type 5 Amps copmplete all as specified and directed.
S & F Bell, AC, 230 volts, single pole complete all as specified and directed.
S&F socket outlet flush type 5 Amp 5 Pin complete all as specified and directed.
S&F switch socket combination 2 in one, 5 Amp flush type 5/6 pin complete all as specified and directed.
S&F switch socket combination 2 in one 6 pin 5/15 Amp flush type complete all as specified and directed.
S&F ceiling rose surface type bakelite 65x20mm two to three terminals AC, 230V, 50HZ complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.
S & F LED linear light fittings 20 Watt basic all purpose surface and wall mounted and LED batten with polycarbonate housing and intrigated electronic driver and connecting with 3 core flexible copper cable PVC insulated of size 16/0.20 mm etc complete all as specified and directed. Make:- Havells Cat No. LHEWEBP7IN1W020 or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and fix bulk head fitting LED type comprises of pressure die cast housing acrylic diffuser and frame complete of 10 watt complete all as specified and directed. Make:- Havells Cat No. RUGBYNEONFT10WLED760SSYMBOPC of Havells or equivalent to Bajaj/Philips/ Wipro/ Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
S & F LED Bldg Security light fitting of 25 watt fixed on & incl MS bracket, made out of 25 mm bore medium grade GI pipe 1.5 mtr long with MS clamps and nut bolts of suitable size complete all as specified and directed. Make:- Havells Cat No. ENDURAPEARLSL25WLED 757SASYTOPC or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/ M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and fix LED ADORE 10 W B22 CDL 3 STAR LAMP complete all as specified and directed.
Supply and fix sheet metal enclosure for DB's SPN with 200 Amps rated bus bar 240Volts, 08 way double door etc complete all as specified and directed.
Supply and fix MCB SPN 40 Amps 240 Volts 'C' series complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps 240 Volts 'C' series complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 m deep bellow ground level) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exceeding 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES Schedule 2009, Part-I complete all as specified and directed.
M&L for fan hook fabricated with MS flat 25x6mm 300 mm long 02 Nos bend to shape drilled with holes and MS buts bolts and washers of required side with one coat of primer and two coats of paints complete all as specified and directed.
Taking down ceiling fan of any sweep & size and refix in same position after overhauling / sevicing / greasing etc incl re-winding of ceiling fan of size 1200-1400 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring (approximate weight of winding wire 250 -300 gms /fan) so as to achieve original specifications i.e. current rating and RPM including all insulating materials, bushes etc re-assembling including testing for continious 2 hrs complete all as specified and directed. Note:- (a) RPM test of ceiling fan with suitable tachometer will be done in the presence of Engineer-in-Charge. (b) All T&P will be provided by the contractor with in the rates quoted for the item including minor repairs by replacement of capacitor, safety pin, cap, nuts & bolts etc and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose to fan, including testing to ensure efficient functioning including application of one coat of synthetic enamel paint by spray painting & rewriting number complete all as specified and directed
S & F plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and provision of flexible copper cable from ceiling rose including taking down of unserviceable exhaust fan of any size and deposit it to MES store yard complete all as specified and directed. Make:- Bajaj Maxima DX 5 blade ( 250 mm) or equivalent in Crompton Greaves/ Khaitan/Havells/Orient
M/S SANJIB DEB
M/S SUBHAM ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .