Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹27.8 L+₹1.1 L (4.24%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹31.2 L+₹4.6 L (17.1%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹32.8 L+₹6.2 L (23.3%)Rejected-Finance | L4 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹33.3 L
EMD Value
₹66,680
Closing Date
2 Mar 2022, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH AND RH KIRKEE PUNE 411003
REPAIR MAINT OF PUMP MOTORS SUBMERSIBLE PUMP MOTOR AND EXTERNAL WATER SUPPLY INCOMING AND DISTRIBUTION SYSTEM AT AUNDH AND MH AMD RH AREA UNDER GE MH AND RH KIRKEE
2022_MES_505354_1
8272/E8
Open Tender
Civil Works
Item Rate
270 days
KIRKEE AND AUNDH
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹66,680
Yes
28 Mar 2022
2 Feb 2022
4 Mar 2022
2 Feb 2022
2 Mar 2022
16 Feb 2022
2 Feb 2022 - 9 Feb 2022
Amount
M & L for dismantling ,transporting to civil workshop centrifugal pump coupled with electric motor 60/75HP (Make: Kirloskar Model-DSM 100-36), Split opening of following capacities pumpset including cleaning with kerosene/petrol for removing dirt supply and replacement of small parts like impeller nut ,lock,washer, packing,gasket greasing oiling and reassembling, connecting in position testing, commissioning the pumpset complete all as directed.(Major Part will be Measured and paid in relevant Items of this schedule)
All as per item No 1 above but 30/40 HP pump set
All as per item No 1 above but 15/20/25 HP pump set
All as per item No 1 above but 7.5 HP pump set
M & L for taking down carefully electric motor of 60/75HP (Make: Kirloskar Model-DSM 100-36), 3-phase 415v,50Hz,AC from foundation/ coupling, transporting to civil workshop, opening the motor,Checking the insulation value of the windings, insulating the winding with same class of insulation varnish,Oiling Greassing of bearing and busing , painting with one coat of synthetic enamel paint as per color code and back to site for re-installing the motor and connecting to the pump, testing the motor for satisfactory performance all as directed by Engineer -in-Charge and all as specified for the following capacity. (Major Part will be Measured and paid in relevant Items of this schedule)
All as per item No 5 above but 30/40 HP pump set
All as per item No 5 above but 15/20/25 HP pump set
All as per item No 5 above but 7.5 HP pump set
Supply and fix in replacement of theTaper roller bearing suitable for 60/75HP electric motor required as directed
Supply and fix in replacement , ball bearing suitable for 30/40 HP motor
Supply and fix in replacement ball bearing suitable for 15/20/25 motor
Supply and fix in replacement ball bearing suitable for 7.5HP motor
Supply and fix in repairs terminal block for the Pump coupled to 60KW/75HP (Make: Kirloskar Model-DSM 100-36).
All as per item No 13 above but for 30/40 HP pump set
All as per item No 13 above but for 15/20/25 HP pump set
All as per item No 13 above but for 7.5 HP pump set
Supply and fix replace bush for Pump coupled to 60/75HP (Make: Kirloskar Model-DSM 100-36)
All as per item No 17 above but for 30/40 HP pump set
All as per item No 17 above but for 15/20/25 HP pump set
All as per item No 17 above but for 7.5 HP pump set
Dismantling and taking out pump motor coupled to 60KW/75HP (Make: Kirloskar Model-DSM 100-36) ,transporting the same work shop opening the motor, removing burnt winding and cleaning winding slots and rewinding of motor using suitable gauge/ size with supper enamelled copper wire, replacing insulation paper of class F and fire proof sleeves, varnishing complete, oiling, greasing, replacing old rear/ front bearings with new and reassembling complete motor including testing at site all as directed by Engr- in -charge
All as per item No 21 above but for 30/40 HP pump set
All as per item No 21 above but for 15/20/25 HP pump set
All as per item No 21 above but for 7.5 HP pump set
Disconnecting electrictrical and mechanicaly and taking out submersible motor pump set 25 HP capacity complete from installed position/ sump , disconnecting of motor, transporting the motor to local workshop ,Split opening of the motor, removing burnt winding and cleaning the slots and rewinding of motor using new super enameled copper winding wire of suitable gauge / size, replacing paper insulation of suitable class and fire proof sleeves, varnishing etc. complete with oiling, greasing, replacing unsv thrust bearing and bushes after repairing , reassembling complete pump and motor after repairing lowering in existing position and testing all as specified and directed .
Disconnection of electric connection taking out of submersible pump set of capacity 25 HP 415 volt 3 phase complete from sump disconecting of pump from coupling shaft transportation to local workshop Split opening of pump impeller for necessary repair work such as grinding reallignment replacement of unserviceable bearings, bushes shaft seal,impellers,coupling all other parts for its serviceability after repairing , testing of pump and lowering in existing position all as specified and directed .
Disconnecting electrictrical and mechanicaly and taking out submersible motor pump set 3 HP capacity complete from installed position/ sump , disconnecting of motor, transporting the motor to local workshop ,Split opening of the motor, removing burnt winding and cleaning the slots and rewinding of motor using new super enameled copper winding wire of suitable gauge / size, replacing paper insulation of suitable class and fire proof sleeves, varnishing etc. complete with oiling, greasing, replacing unsv thrust bearing and bushes after repairing , reassembling complete pump and motor after repairing lowering in existing position and testing all as specified and directed .
Disconnection of electric connection taking out of submersible pump set of capacity 3 HP 415 volt 3 phase complete from sump disconecting of pump from coupling shaft transportation to local workshop Split opening of pump impeller for necessary repair work such as grinding reallignment replacement of unserviceable bearings, bushes shaft seal,impellers,coupling all other parts for its serviceability after repairing , testing of pump and lowering in existing position all as specified and directed .
Taking down old existing unserviceable cast iron pipe and M& L 300 mm dia CI pipes with both ends flanged centrifugally cast, class -'B', conforming to IS 8329/ 2000, in any length suitable for flange joint complete all as specified & directed. Note- CI fitting and joint measured and paid seprately )
All as per item No 29 above but CI pipe 200 mm dia
All as per item No 29 above but CI pipe 150 mm dia
All as per item No 29 above but CI pipe 100 mm dia
All as per item No 29 above but CI pipe 80mm dia
Taking down fiber board gasket joint and M&L for joint with rubber or fibre board gasket complete with suitable size nuts, bolts and washers etc as directed for flanged pipes & fittings for 300 mm dia pipe.
All as per item No 34 above but for pipe of 200 mm dia
All as per item No 34 above but for pipe of 150 mm dia
All as per item No 34 above but for pipe of 100 mm dia
All as per item No 34 above but for pipe of 80 mm dia
Taking down unserviceable CI/DI/ fitting of any discription and M&L cast iron fitting (any type radius and angle) taper any type (Straight) bend increasing decreasing or double socket etc Tee pieces, single branch ‘Y’ junction double branch, coller, capacity and plugs for up to 150 mm bore CI pipe conforming to IS-1538- 1976 complete and all as specified and directed.
All as per item No 39 above but size 150 mm to 400 MM bore
Taking down unserviceable foot valve and supply and fixing 150 MM dia foot valve of following sizes including jointing materials all as specified and directed of Normax
All as per item No41 above but 100 MM dia
All as per item No 41 above but 80 MM Dia
Taking down unserviciable and S & F in repair tyre coupling of size A-18 with existing alignement all as specifiedand directed
Taking down unserviciable andS & F in repair tyre coupling of size A-42 with existing alignement all as specifiedand directed
S & F in repairs tyre coupling A-60 with existing alignement all as specifiedand directed
Supply and fix in repairs 3 pole power contactor 2 NO +2 NC, ML 4 three phase, AC 440 volts, 50Hz, 100 Amps AC-1, 70 Amps AC3 . (Make - L&T CAT part No. SS90910 or equivalent rating on other make )
Supply and fix in repairs 3 pole power contactor MNX 25 AC-1 rating 25 A and AC 3 rating 45 A three phase, AC 440 volts, 50Hz, (Make - L&T Cat part No. CS14110 or equivalent rating on other make )
Supply and fix in repairs ST timer 100 range 3-30 Sec coil voltage 240/360/415 Volt AC . (Make - L&T CAT part No. ST803280000 or equivalent rating on other make )
Supply and fix in repairs thermal overhead relay MN-5 with start and off/reset of Amps range 66-110 Amps Make- L& T Cat No SS94137 or Equv in C& S
Supply and Fixing in replacement Water pressure gauge of capacity 5 Kg/mm2 gauge 8 " or 6" (size of dial) all as directed (Make- ISI Make)
Supply and fix in repairs Non Return Sluice Valve of 300 MM Dia, Class PN 1.6, hydrodynamically guided, closing non return valve with gray Cast iron body, synthetic rubber coated reinforced ball, flanged type including 6mm thick rubber gasket, MS nuts, bolts and washers and dismantling the unserviceable NRV all as directed.
All as per item No 52 above but 200 MM Dia
All as per item No 52 above but 150 MM Dia
All as per item No 52 above but 80 MM Dia
Taking down unserviciable cable and Supply and laying 185 Sqmm 4 Core PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade.
All as per item No 59 above but 95 Sqmm 3.5 Core
All as per item No 59 above but 50 Sqmm 3.5 Core
All as per item No 59 above but 35 Sqmm 3.5 Core
All as per item No 59 above but 10 Sqmm 4 Core
Supply and fix in repairs sluice valve 400mm dia cast iron body double flanged type PN1.6, with SS Spindle, ISI Mark of following capacities
All as per item No 64 above but 300mm dia
All as per item No 64 above but 200 mm dia
All as per item No 64 above but 150 mm dia
All as per item No 64 above but 100 mm dia
All as per item No 64 above but 80 mm dia
Supply and fix in repairs air release valve cast iron body flanged type double acting type, ISI Mark of 80 mm Size
Supply & fix in repair SS wire rope with PVC Coating of size 10mm dia complete all as specified
Supply and fix in repair rubber gland packing suitable for sluice valve 400 mm dia.
Supply and fix in repair rubber gland packing suitable for sluice valve 300 mm dia.
Supply and fix in repair rubber gland packing suitable for sluice valve 200/150 mm dia.
Supply and fix in repair rubber gland packing suitable for sluice valve up to 100/80 mm dia.
Repair of NRV of size 200 mm flanged type by opening and cleaning inner plate spendle ireplacement of 6mm thick rubber gasket, MS nuts, bolts and washers after repairing refixing the same in existing position all as specified and as directed.
M&L painting of ,motor complete set including base plate, of capacity up to 40 HP motors with two coat of synthetic enamel paint after preparing surfaces all as directed by Engineer-in-Charge.
M&L painting of pump,motor complete set including base plate, of capacity 60 HP to 75 HP motor with two coat of synthetic enamel paint after preparing surfaces all as directed by Engineer-in-Charge.
M&L for cleaning with surface dressing or trimming of natural ground bushes/small trees/shurbes including removing and carrying away the rubbish from site to a distance not exceeding 50m away from all as specified and directed by Engineer-in- charge.
Supply and fix in replacement RYB indicator lamp LED type (Set of three lamp) for incoming and outgoing supply as per existing sizes all as directed by Engr-in-Charge.
Supply and Fix in replacement of CTs of 200/5 current rating AC, 415 V, three phase including connecting to supply as per existing all as directed by Engr-in-Charge.
Supply and fix in replacement Ammeter three phase digital type 50 HZ, AC as per existing sizes/ range all as directed by Engr-in-Charge.
Supply and fix iin replacement voltmeter three phase digital type 0-500 V, 50 HZ, AC as per existing sizes all as directed by Engr-in-Charge.
S & F single phase preventor relay SPPR type Sz5(6 wire) 415 V 50 Hz Make Siemens or equevelent approvd make
M&L for replacement of submersible cable round/flat of 3 core 6 Sqmm with multistanded copper coundecter all as directed.
Taking down unserviciable MS work and M& L for fabrication/structural work with mild steel sheet/ angle iron in any shape or size as indicated or directed and including belding/ bracing, painting with one coat of red oxide primer and two coat of black paint (one coat before fixings and one coat of black paint after fixing ) complete all as specified and directed.
M&L for PCC 1:3:6 ,Type C2, using 40mm graded aggragate for foundations, filling and mass concrete
Material and labour in repair of mild steel plates (plain or chequered) of 5mm thick or over in thickness in available sizes Fe-290 (Gde E-165) complete all as specified and directed.
Supply only PPM testing kit for portable/ drinking water measuring range 0.2 PPM to 5 PPM all as specified and directed (Make- Any approved Coy From Govt Lab)
Taking down unserviciable cable and S & F 10 Sqmm 3 Core PVC insulated, unsheathed industrial cable with flexible bright annealed copper conductor for voltage grade up to 1100 volts conformimg to IS 694.
All as per item No 91 above but 16 Sqmm 3 Core
All as per item No 91 above but 35 Sqmm 3 Core
Taking down of existing unsearviceable water meter 300 mm dia by disconnecting of all nuts bolts and repair the same by replacing all unserviceable parts and calibration / testing the same from MIDC water works authority complate all as specified and as directed
ONKAR ELECTRIC AND GENERAL STORE
K.K.Enterprises
Star Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .