Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹33.3 L+₹11.8 L (54.5%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
17 Oct 2023, 6:00 pmClosed
CWE (AF) SECUNDERABAD
CWE (AF) SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
REPAIRS / PERIODICAL MAINTENANCE OF STAND BY DG SETS AND CONNECTED WORKS AT AFA HYDERABAD
2023_MES_618169_1
86726/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AFA HYDERABAD
₹58,000
Yes
31 Oct 2023
11 Sept 2023
19 Oct 2023
11 Sept 2023
17 Oct 2023
28 Sept 2023
11 Sept 2023 - 23 Sept 2023
Amount
M&L for the following Periodical Maintenance / Servicing for diesel Gen set installed at AFA for trouble free operation of generator sets and ensuring the serviceability , carrying out minor spares (if any/ settings required for operation of the set shall be carried out without any extra cost for the following capacity Model / Make by carry out the inspection /work by an authorized service centre including within Two months from the date of commencement and once in every three months subsequently. Engine Maintenance (i) Changing the lubricant oil (ii) Checking the oil level in complete DG sets (iii) Checking of alternator, checking/changing fan belt if required (iv) Checking of circuits of various controls of engine (v) Draining the water seperator bowels to remove water/sediments (vi) Checking and tightening of all external fasteners (vii) Checking and tightening of all lube and fuel/hose connections (viii)Changing of fuel filter, Lub oil filter and Air filter if required (ix) Arresting all water /lubricant/fuel leakages and topup (x) Checking of all engine parameters (xi) Checking of the electrical exitation system (xii) checking all the performance of AMF panel in all respect
Note :- (i) All repairs/periodical maintenance shall have to be carried out by the authorised service personnel (ii) Sspares, lubricant etc required for engine, alternator & AMF panel will be measured and paid separately under relevant items.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Capacity Above 62.5 KVA and upto 125 KVA Capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Capacity Above 125 KVA and upto 320 KVA Capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Capacity Above 320 KVA and upto 625 KVA Capacity DG Set of Make : - Kirloskar / Cummins / Greaves
Supply and fixing of Engine Oil seal and gasket for the DG Set of the following Capacity including removal of old u/s gasket and oil seal including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing in Repair of V belt for following Capacity DG sets including removal of old u/s V belt including connection up complete all as specified and as directed. Make :- Fenner, Finex Supreme.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Ammeter suitable for following Capacity DG sets including removal of unserviceable Ammeter including connection up complete all as specified and as directed for the following :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of oil pressure guage for following Capacity DG sets including removal of unserviceable oil pressure guage including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of speedometer cable for following Capacity DG sets including removal of unserviceable speedometer cable including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of push button switch for stop/start of DG engine for following Capacity DG sets including removal of unserviceable push button switch including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Ignition switch for following Capacity DG sets including removal of unserviceable Ignition switch including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Lub Oil filter set for following Capacity DG sets including removal of unserviceable Lubrication Oil filter set including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Diesel filter set(Primary and Secondary) for following Capacity DG sets including removal of unserviceable/s Diesel filter set including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Air filter set (Inner and Outer) for following Capacity DG sets including removal of unserviceable Air filter set including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Universal multi function relay in AMF panel of DG set for following Capacity including removal of unserviceable relay including connection up complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing of Power contactor 4 pole of capacity 800 A with auxiliary contactors of 2 NO's and 2 NC's confirming to TC contactors of equivalent in ABB, L&T schneider, C&S suitable for AMF panel of DG set cap 500 to 625 KVA complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 600 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to TC contactors or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of DG set cap 320 to 400 KVA complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 400 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to TC contactors or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of DG set cap 160 to 250 KVA complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 200 to 250 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to MEC LS Model GMC-180/4 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of DG set cap 82.5 to 125 KVA complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 150 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to MEC LS Model GMC-180/4 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of DG set cap 50 to 63 KVA complete all as specified and as directed.
S&F of Power contactor 4 pole of capacity 63 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to L&T Model MCX11 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of DG set cap 15 to 40 KVA complete all as specified and as directed.
M&L for filling / topup of distilled water for the batteries of the DG Sets complete all as specified and as directed.
Supply and fixing solenoid switch, including removing of unserviceable solinoid switch from Gen set including accessories like nuts, bolts washers etc complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and fixing self starter 12/24 Volt DC, including removing of unserviceable self starter 12/24 volts DC from Gen set including accessories like nuts, bolts washers etc complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
M&L for remove the unserviceable winding of self starter 12/24 volts DC from Gen set of following capacity DG set including rewinding of unserviceable burnout winding with high conductivity best quality super enamelled copper winding, including replacement of insulated material, wires bushes etc complete all as specified and as directed for following capacity DG sets :- Note :- copper wire will be measure and paid seperately under relevent items of Schedule 'A' / BOQ
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repairs new armature with brushes and brush holder for dynamo of following DG set capacity including removing the burnout armature , clean the internal surfaces ,servicing, complete all as specified and as directed for following capacity DG sets :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply and refilling Coolant suitable for Diesel generating sets of any capacity complete all as specified and as directed.
Supply and fixing hose pipe of any size and dia with bengo washer in 15 to 625 KVA DG sets complete all as specified and as directed.
Removing the unserviceable Diesel level indicating plastic pipe of approx size 10 mm dia and both end clamps and replace with new Plastic pipe of same size to the required level and clamps on both the sides complete all as specified and as directed.
Remove the radiator from the gen set drain out the coolant servicing, arresting leakages by welding/brazing etc, supply and replacing the u/s mounting rubber, clean the internal surfaces and de-scale by using cleaning agents and fixing back in position complete all as specified and as directed for the following capacities :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Material and labour for repairs to the following DG Set alternator and removing the same from engine of DG Set, transporting the same to the work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing complete all as specified and as directed. Note :- Copper winding material will be measured and paid seperately under relevent item
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Remove the fuel injection pump from the engine transport to an authorized service centre for servicing, calibration and to adjust by replacing the following U/S worn-out spares with new appropriate make spares and bringing and fixing to the engine and tune up for maximum efficiency complete all as specified and as directed for the following capacity of DG set s :- Note :- Major spares required will be measured and paid seperately:
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply Only orifice for following capacity DG sets :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply Only Barrel and Plunger for following capacity DG sets :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
Supply Only FIP Bearing for following capacity DG set :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair exhaust fan of metal body size 300 mm sweep 230 Volt, 1400 RPM, including fixing and connecting complete all as specified and as directed.
S&F in repair exhaust fan of metal body size 350 mm sweep 230 Volt, 1400 RPM, including fixing and connecting complete all as specified and as directed.
S&F in repair exhaust fan of metal body size 400 mm sweep 230 Volt, 1400 RPM, including fixing and connecting complete all as specified and as directed.
S&F in repair HRC Fuse unit 20Amp to 100 Amp Capacity for DG Sets complete all as specified and as directed.
S&F in repair HRC Fuse unit 120Amp to 165 Amp Capacity for DG Sets complete all as specified and as directed.
S&F in repair Generator set controller unit of AMF Panel for following capacity DG Sets as per existing model of Make Kirloskar / Cummins / Greaves complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair MCCB 32 Amps 3 pole, model DU 100 suitable upto 62.5KVA DG set AMF Panel complete all as specified and as directed. Make :- L&T, Schneider, Havells, C&S, ABB, Legrand.
S&F in repair MCCB 125 Amps 4 pole, model DPX3 160 suitable to above 160KVA to 400 KVA DG set AMF Panel complete all as specified and as directed. Make :- L&T, C&S, Havells, C&S, ABB, Legrand.
Taking out existing outlived old engine oil, clean the engine oil sump and filling/ Top up engine oil 15 W 40 to DG Sets of capacity 15 to 625 KVA complete all as specified and as directed. Make : - Servo / Castrol / Valvoline / Kirloskar / Power Oil / Electrol
S/F in repair water pump DG sets as per existing model of following capacity, including necessary dismantling to existing pump including necessory testing to the entire satisfaction of Engineer-in-Charge.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
M & L for repairing door of DG set as per existing damaged doors including necessory items like Left & Right side Door hinges and door locks with keys complete all as specified and as directed. of Make Kirloskar / Cummins / Greaves
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair of unserviceable IEVR - II ( industrial electronic voltage regulator) as per existing model making connection, including taking down existing IEVR of Make :- Kirloskar / Cummins / Greaves complete all as directed and as specified.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair of electronic control panel governor of following DG Set asper existing model of Make :- Kirloskar / Cummins / Greaves complete all as specified and as directed.
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Sensor Unit for engine safety control unit (precol panel assembly) of DG sets as per existing model of capacity 15 KVA up to 100 KVA, including taking down old unserviceable complete all as specified and as directed.
S&F in repair Sensor Unit for engine safety control unit (precol panel assembly) of DG sets as per existing model of capacity above 100 KVA up to 320 KVA, including taking down old unserviceable complete all as specified and as directed.
S&F in repair Sensor Unit for engine safety control unit (precol panel assembly) of DG sets as per existing model of capacity above 320 KVA up to 500 KVA, including taking down old unserviceable complete all as specified and as directed.
Supply and fixing copper wire 10 Sqmm copper conductor unsheathed, multistranded, PVC insulated, 1100 volts grade, single core cable to panel board / AMF Panel of DG set of any capacity complete with thimble, lugs and connector etc as required side complete all as specified and as directed.
Supply and fixing copper wire 16 Sqmm copper conductor unsheathed, multistranded, PVC insulated, 1100 volts grade, single core cable to panel board / AMF Panel of DG set of any capacity complete with thimble, lugs and connector etc as required side complete all as specified and as directed.
S/F in repair Alternator AVR (automatic voltage Regulator) card of DG Sets of capacity 15 KVA upto 250 KVA DG set as per sample of Make :- kirloskar / Cummins / Stamford
S/F in repair Alternator AVR (automatic voltage Regulator) card of DG Sets above 250 KVA upto 625 KVA DG set as per sample of Make :- kirloskar / Cummins / Stamford
S&F in repair of AMF panel contactor coil as per existing model of capacity 15 KVA up to 250 KVA complete all as specified and as directed. Make :- :L&T or equivalent approved make
S&F in repair of AMF panel contactor coil as per existing model of capacity above 250 KVA up to 500 KVA complete all as specified and as directed. Make :- :L&T or equivalent approved make
Opening of tappet cover and carrying out necessary adjustments of the tappets, push rods, rocker arms etc, upto 625 KVA Kirloskar/Cummins engine, including S/F of set of Gasket set, minor spares including refixing and testing complete all as specified and as directed.
S&F in repair of Anti Vibration pad for 160/200 KVA DG Set including taking down anti Vibration existing padof DG Set complete all as specified and as directed.
S&F in repair Module Electronic Control as per existing, incuding taking down unserviceable existing Module Electronic Control of 160/200 KVA DG Set and connecting complete all as specified and as directed.
S&F in repair VMR 3 P ( Voltage Monitoring Relay Protection of 3 Phase) (REL ) as per existing model of following DG Sets and making connections, including taking down existing VMR complete all as specified and as directed for the following :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Fuel water separator filter for DG Set as per existing model of following capacity including taking down existing complete and all as directed and as specified for the following :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair Super bypass filter for DG Set as per existing model of following capacity including taking down existing complete and all as directed and as specified for the following :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair VSP D2 (Phase failure realy) for DG Set as per existing model of following capacity including taking down existing complete all as specified and as directecd for the following :-
Capacity 15 KVA and up to 62.5 KVA capacity DG Set
Above 62.5 KVA and upto 125 KVA Capacity DG Set
Above 125 KVA and upto 320 KVA Capacity DG Set
Above 320 KVA and upto 625 KVA Capacity DG Set
S&F in repair PCB assembly of DG Sets of capacity 15 KVA up to 250 KVA as per existing model of following capacity including taking down existing complete all as specified and as directecd.
S&F in repair PCB assembly of DG Sets of capacity above 250 KVA up to 500 KVA as per existing model of following capacity including taking down existing complete all as specified and as directecd.
Taking down Turbo charger assembly from the DG Sets of capacity 320 to 625 KVA make -Kirloskar/Cummins engine and carrying out for cleaning and overhawling including providing minor spare parts/ Repair kit and Refixing the same complete for optimum out put of the engine complete all as specified and as directecd.
Supply only copper winding wire for the Item No 22 and 28, and Rewinding with supper enameled copper wire as per existing guages and turn with necessary heats, varnishing to achieve insulation Resistance to required mega ohms complete all as specified and as directecd.
Supply & Fixing battery terminal lead including terminals (Positive) and necessary lugs and applying silica gel complete all as specified and as directecd.
Supply & Fixing battery terminal lead including terminals (Positive) and necessary lugs and applying silica gel complete all as specified and as directecd.
M&L for draining out complete fuel from the tank and taking out the tank from the base for removing the rusted sludge by scrubbing the internal surface with wire brushes. After cleaning the tank re-install back in position and connection with other accessories complete all as specified and as directecd.
M&L steel tubing fuel pipe of above 250 up to 625 KVA DG set as per existing size from fuel tank to fuel filter of DG set alongwith all accessories for fitting and welding as required including taking down old unserviceble fuel pipe complete all as specified and as directecd.
S J REDDY
Bidder Name
AKSHITA ELECTRICAL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .