Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE BID | |
| 2 | L2₹25.4 L+₹2.9 L (13.0%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BID | |
| 3 | L3₹27.7 L+₹5.3 L (23.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹28.6 L+₹6.1 L (27.3%)Rejected-Finance WARD NO 13 NEW SURATGARH | SURATGARH | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹29.6 L+₹7.1 L (31.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 May 2024, 6:00 pmClosed
LT COL PRIYESH SRIVASTAVA
GE (AF) SURATGARH
REPAIR/MAINT OF FANS (CEILING, WALL MOUNTED, EXHAUST), GEYSER ALONGWITH CONNTECTED E/M WORKS AT AF STN SURATGARH
2024_MES_650043_1
8151
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
11 documents required · 11 mandatory
₹500
GE (AF) SURATGARH
₹70,000
Yes
11 Jun 2024
13 Apr 2024
15 May 2024
13 Apr 2024
13 May 2024
29 Apr 2024
Amount
BOQ (RREPAIR/MAINT OF FANS (CEILING, WALL MOUNTED, EXHAUST), GEYSER ALONGWITH CONNTECTED E/M WORKS AT AF STN SURATGARH)
Taking down unserviceable ceiling Fan of following sizes of any make dismantling cutting and removing of old burnt windings and rewinding with super enamelled copper winding wire of required size including allied insulation material, varnish, sleeves etc. greasing, oiling, re-assembling testing and refixing in the same position , complete all as specified and directed by the Engineer-in-Charge.
1200 mm sweep
1400 mm sweep
All as per serial item no 1 above but Exhaust Fan of following size and any make.
450 mm size
300 mm size
230 mm size
All as per serial item no. 1 but wall Fan of following size and any make.
450 mm size
600 mm size
All as per serial item no. 1 but Air circulator of following size and any make.
450 mm size
600 mm size
750 mm size
Supply and fixing in replacement of capacitor of 3.15 mfd including fixing complete and including necessary items such as sleeves etc, complete all as specified and directed by the Engineer-in-Charge. Make: EPCOS/HAVELLS
S & F Step 0-4, electronic regulator for ceiling fan 1200/1400 mm sweep, 240 volts, 100 Watts humfree single pole in replacment ,complete all as specified and directed by Engineer-in-Charge. Make : Legrand/Anchor /Plaza .
Supply and fixing in replacement of bush / bearing of suitable size in ceiling Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of bush / bearing of suitable size in Exhaust Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
Exhaust Fan of 450 mm sweep
Exhaust Fan of 300 mm sweep .
Exhaust Fan of 230 mm sweep
Supply and fixing in replacement of bush / bearing of suitable size in wall Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
Wall mounting Fan of 450 mm sweep
Wall mounting Fan of 600 mm sweep .
Supply and fixing in replacement of bush / bearing of suitable size in Air circulators Fan of following size, complete all as specified and directed by the Engineer-in-Charge. Make : NBC/ SKF.
Air circulator Fan of 450 mm sweep
Air circulators Fan of 600 mm sweep
Air circulators Fan of 750 mm sweep
Supply and fixing in replacement of Metallic clamps for hanging of ceiling Fan with bolts & nuts,, split pin etc., complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of Stator of Ceiling Fan of following size, complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan 1400 mm sweep
Supply and fixing in replacement of Rotor of ceiling Fan of following capacity, complete all as specified and directed by the Engineer-in-Charge
Ceiling Fan of 1200 mm sweep
Ceiling Fan 1400 mm sweep
Supply and fixing in replacement of PVC canopy for ceiling Fan (upper & lower) of following capacity, complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of Blade set for ceiling Fan of following capacity with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of cast Aluminium Body cover for ceiling Fan of following capacity with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Ceiling Fan of 1200 mm sweep
Ceiling Fan of 1400 mm sweep
Supply and fixing in replacement of rubber reel/pad of suitable size for ceiling Fan of any size and make, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of MS down rod of length 450 mm for ceiling Fan of any size and make, complete all as specified and directed by the Engineer-in-Charge.
Spray painting with synthetic enamel paint of (shade as approved by Engineer – in – Charge) after preparation of old surface of ceiling Fan/ exhaust Fan of any make/model/sweep and marking MES No with synthetic enamel paint, complete all as specified directed by the Engineer-in-Charge.
Supply and fixing in replacement of Metallic Blade set for Exhaust Fan of following size with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Exhaust Fan of 450 mm sweep .
Exhaust Fan of 300 mm sweep .
Exhaust Fan of 230 mm sweep
Supply and fixing in replacement of Metallic louvers for Exhaust Fan of following size with bolts etc., complete all as specified and directed by the Engineer-in-Charge.
Exhaust Fan of 450 mm sweep .
Exhaust Fan of 300 mm sweep .
Exhaust Fan of 230 mm sweep
Taking down ceiling Fan of any size, any make fixed/hanged at different location in Air Force area, dismantling the Fan and servicing, greasing, oiling and cleaning complete and re-assembling the same including replacing split pins flexible copper cable of size 23/0.0076 twin core, 70cm long and refixing the ceiling Fan on the same location in original position, testing and commissioning of Fan for smooth running, as per entire satisfaction of Engineer-in-Charge. Note:- (i)Quoted rate by tenderer of any item of the schedule is inclusive of taking down the ceiling Fan from the position for carrying out servicing repair transportation to work shop & back, changing any component and re-fixing/hanging in position connecting and testing complete.(ii) Rewinding work and replacement of shares shall be measured and paid separately under appropriate items.
All as per serial item No. 22 above but Exhaust Fan of any size and any make
All as per serial item No. 22 above but wall mounted Fan of any size and any make.
All as per serial item No. 22 above but Air circulator fan of any size and any make
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed.
S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer-in-Charge.
S&F wall fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and directed by Engineer-in-Charge. Note :- Temporary power supply shall be provided by contractor.
M & L for Point wiring (surface) complete with FR PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following , complete all as specified and directed by Engineer-in-Charge.
One light/fan point controlled by one switch.
S&F Switch piano flush button single pole one way 5 amp 240 volts, including connecting and testing , complete all as specified and directed by Engineer-in-Charge.
S&F Ceiling rose, surface bakelite, 65 x 50mm, three terminals, including connecting and testing, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully water heater (Geyser) any capacity any make after removing electric & water connections from existing system for carrying out repairs(Repairs will be measured and paid separately) and refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge.
M&L painting with two coats of white synthetic enameled paint and marking MES No by black permanent marker and reconnecting the same after satisfactory completion of work all as directed by Engineer-in-Charge
Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete
Replacement of heating elements spiral /circular type 2.0 kW for 50ltrs capacity geyser, the heating element should be as per specified geyser any type ISI marked.
Replacement of heating elements spiral /circular type 1.5 kW for 25ltrs capacity geyser, the heating element should be as per specified geyser any type ISI marked.
Replacement of thermo static switch of geyser.Make : Bajaj/Theta
Supply and fixing Fancy type Bib tap of cast copper alloy with crutch screwed down, screwed for iron pipe of 15mm bore complete all as specified and directed.Make : Zoloto/Jaguar/Prayag complete all as directed by Engineer-in-Charge.
Supply and fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch screwed both ends for iron pipe or for unions of dia 15mm all as directed by Engr-in-Charge .Make : Zoloto/Jaguar/Prayag
Cutting/drilling or taping from existing 15 or 20mm dia G I pipe in position for branch connection of 15mm dia including suitable fitting/fixtures all as directed by Engr-in-Charge.
Replacement of PVC insulated copper (flexible) conductor 2.5 Sqmm 3 core and connected to geyser.Make : Anchor/plaza/Finolex
Replacement of apparatus plate with nut, bolts, clamps, washer, etc. of geyser suitable for Record/Ditz make or any other make and any capacity including PRV & NRV system complete all as directed by Engineer-in-Charge.
Welding with new brass studs for holding of heating element with replacement of suitable element holding clamps-3 nos. complete all as directed by Engineer-in-Charge.
Replacement of indicating Lamp Red and Green of geyser with proper connection, complete all as directed by Engineer-in-Charge.
S&F in repairs apparatus plate bottom cover in two halves made out of GI sheet duly painted all as directed by Engineer-in-Charge.
Detecting the leakage from geyser and arresting the same by brazing/soldering etc all as directed by Engr-in-Charge
S&F vent pipe using medium grade GI tubing 20mm dia fixed to wall/ceiling upto level not less than 15cm from OH tank top level including necessary fittings, fixtures, clamps, except Tee etc. all as directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with MCB SPN 10 Amp for geysers.Make C&S/Havells/Indo Asian
Supply and fix plug top 20/32 Amp suitable for any type of geyser connection all as specified and directed by engr-in-charge
Supply and fix NRV of 15mm dia all as directed at site all as specified and directed by engr-in-charge
S&F Anchor fastning(04 Nos ) of suitable size for fixing geyser make good disturbed surfaces after dismantling old one all as specified and directed by engr-in-charge
S&F GI Pipe medium grade 15mm size fixing in wall with clamps,nut,bolts etc all as directed at site
S&F water heater outer cover suitable for 25ltrs. Capacity of existing make including taking out old unserviceable.
S&F water heater outer cover suitable for 50ltrs. Capacity of existing make including taking out old unserviceable outer.
S&F water heater inner tank suitable for 25ltrs. Capacity of existing make including taking out old unserviceable.
S&F water heater inner tank suitable for 50ltrs. Capacity of existing make including taking out old unserviceable.
Material and labour for fault detection in solar power heaters through authorised agency,rectifying any minor defects all as specified and directed by engr-in-charge
Supply and fixing in replacement of heating element assembly 3/5KW suitable to size of solar water heater all as specified and directed by engr-in-charge.
Supply and fixing in replacement of old solar panel glass suitable for 200/300/500 lts all as specified and directed by engr-in-charge
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note: Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).Make of Cable : Finolex/Polycab/Havells
S/Fix Vertical MCB DB TPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V including provision for mounting MCCB upto 125 Amps rating, complete all as directed by Engr-in-Charge.Make Indo Asian/Havells/Standard/C&S
S/Fix MCB DB SPN 12 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed..Make: Indo Asian / Havells/Standard/C&S
S/Fix MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed..Make: Indo Asian / Havells/Standard/C&S
S/Fix MCB DB SPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed..Make: Indo Asian / Havells/Standard/C&S
Supply and fixing 4 Pole MCCB 63 Amps 50 Hz 415 V with rupturing capacity 16 KA with thermal setting of 80 to 100% of Make Indo Asian/Havells/Standard
Supply and fixing 4 Pole MCCB 100 Amps 50 Hz 415 V with rupturing capacity 16 KA with thermal setting of 80 to 100% of Make Indo Asian/Havells/Standard
Supply and fixing 4 Pole MCCB 125 Amps 50 Hz 415 V with rupturing capacity 16 KA with thermal setting of 80 to 100% of Make Indo Asian/Havells/Standard
S&F MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB .Make: Standard/Indo Asian/Havells (DB will be measured and paid separately under respective items of sch A):-
MCB SPN 5 to 40 Amps.
MCB SP 5 to 40 Amps
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
SHUMMUN ENTERPRISES
M. S. CONTRACTOR
AGGARSAIN BUILDERS
DASHMESH ENTERPRISES
bharat contrectors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .