Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.7 LAccepted-AOC KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | 1 | Accepted-AOC ok | |
| 2 | 2₹18.1 L+₹25,020.34 (1.40%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | 2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | 3₹18.3 L+₹42,671.34 (2.39%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | 3 | Rejected-Finance Quoted rate more than L1 | |
| 4 | 4₹18.9 L+₹1.0 L (5.64%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | 4 | Rejected-Finance Quoted rate more than L1 | |
| 5 | 5₹18.9 L+₹1.0 L (5.64%)Rejected-Finance SANDHYA NIWAS MAGADH COLONY ROAD NO 03 SHERGHATI ROAD PS MAGADH MEDICAL COLLAGE DIST GAYA PIN 823001 BIHAR | GAYA | BIHAR | 823001 | 5 | Rejected-Finance Quoted rate more than L1 |
Tender Value
Refer Docs
EMD Value
₹48,500
Closing Date
21 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT PO- HOTWAR RANCHI Pin- 834012
SPL REPAIRS TO BLDG NO P-8/1, P-8/2, P-8/3, P-8/5, P-8/6, P-8/7 and P-8/8 OF INF BDE OFFRS MESS UNDER GE DIPATOLI
2023_MES_621110_1
8000/1923/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Dipatoli
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dipatoli
₹48,500
Yes
22 Dec 2023
29 Sept 2023
23 Oct 2023
29 Sept 2023
21 Oct 2023
13 Oct 2023
Amount
Demolition of brick work built in cement mortar or lime mortar complete of any description complete all as specified and directed.
M&L Brick work with fly ash bricks modular type, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster including racking out joints, hacking for key, scrubing down with water etc complete all as specified and directed.
M & L for rendering 15 mm thick in cement Mortar (1:4) on the surfaces fair faces of brick work/concrete and finished the surface fair and even (incl. chajja/ facia)complete as specified and d.irected
M & L for rendering 15 mm thick in cement Mortar (1:6) on the surfaces other than fair faces of brick work/concrete/ and finished the surface fair and even complete as specified and directed
M&L for complete removal of existing treatment on wall of any height of bldigs by brooming down with wire brushing, stoping an applying two coats of exterior weather coat/ plastic emulsion under one coat of primer, complete all as specified and directed.
M &L for preparation of newly plastered surface of wall and applying two two coats of exterior Emulsion weather proof coat white or tinted on walls over one coat of primer complete all as specified directed.
M & L for rendering 5 mm thick in cement Mortar (1:3) on the surfaces of ceiliing and finished the surface fair and even complete as specified and directed
M/L preparation of newly / old plastered surfaces of wall and applying a coat of wall care putty 1 mm thick to make the surfaces truly smooth complete all as specified and directed.
M &L for applying two coats of distemper oil emulsion over a coat of primer white or tinted on already prepared wall surfaces (or necessary preparation if required ) complete all as specified and directed.
M &L for applying one coats of distemper oil emulsion on old surfaces of Ceiling including necessary preparation of surfaces complete all as specified and directed.
Demolition of brick bats laid dry including returning filling spreading, levelling, watering and well ramming in layer in sunken floors complete all as specified and directed.
M&L for water proofing treatment to sunken surface of floor slab/skirting/ dome in following sequence:- (a) Laying plain cement concrete padding 1:2:4 Type B0 (using 12.50mm graded stone aggregate) with integral water proofing compound " Pidicrete URP manufactured by M/s Dr. Fixit or equivalent as per manufacturer instructions" ( Note- integral water proofing compound shall be measured in supply only ).
(b) floor / vertacal skirting side plaster in CM 1:3, 15mm thick with and including using " Pidicrete URP" manufactured by Dr Fixit as per manufacturer instruction and 72 Hrs tesing for water tightness by ponding of water.
(c) Applications of two coats of proof coat black manufactured by Dr Fixit or equivalent as per manufacturers instructions all over and testing again for water tightness by ponding of water for 72 Hrs.
M&L cement concrete 1:5:10 Type E2 (40mm graded brick aggregate) as in mass concrete complete all as specified and directed.
Taking down chowkhat or frame with shutters ( without taking off shutters from the frames) n exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkhat or frame with shutters ( without taking off shutters from the frames) Exc 1.50 Sqm but n exc 4 Sqm Sqm each complete all as specified and directed.
Taking down shutters area n exc 1.0 Sqm each complete as specified and directed.
Providing and fixing of powder coated aluminium three track sliding glazed window manufactured with approved aluminium section with three sliding shutters each shutter width one half of the length of window with the following specification and making good the adjascent surfaces :- (a) Window frame of cross section 101mm x 40 mm x 1.5 mm thick. (b) Three way track for sliding shutters of cross sections 91.80mm x 31.75mm x 1.1 mm thick. (c) Sliding shutter frame of cross section 40 x18 x 1 mm (d) Aluminium glazing strip of size 18.2 x 16.66mm (e) 4 mm thick float glass superior quality for 2 shutters. (f) IDPE rubber gasket for fixing glass (g) Locking cleat per shutter 01 Nos. (h) 02 Nos sliding rollers per shutters. (j) Aluminium wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm for one shutter. (k) Fixing screws for frame with wall 06 per window
S & F Powder coated aluminium ventilator louvre type with frame, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, side handles fixed to wall with fastener etc, complete all as specified and as directed.
S & F Powder coated aluminium door frame of approved manufacturer using approval aluminium section of following sizes fixed to floor, wall with rawl plug and screwe, etc, complete all as specified and as directed. (a) Door frame of size 95.25mm x 44.45mm x 1.5mm
Dismantling existing water tanks 1000 ltr and removing to stores complete all as specified and directed.
S&F in repair hoisting 3 layers PVC tank 1000 litres capacity including supply & Fix 20mm dia brass float valve assembly complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar beding layer complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick over10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but n.exc 0.11 sqm as in floor etc, with and including over 15 mm thick screed bed in CM(1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and as directed.
M/L vitrified ceramic tiles light shade 10 mm thick (square / rectangular ) polish, area of each tiles not exceeding 0.36 Sqm in size as in floor etc set and jointed, joint free and pointed in white or coloured cement to match incl 20 mm thick screed bed in CM 1:6 on concrete surface rough finish to recive tiles all as specified and directed.
M/L vitrified ceramic tiles light shade 10 mm thick (square / rectangular ) polish, area of each tiles not exceeding 0.36 Sqm in size as in dado / skirting etc set and jointed, joint free and pointed in white or coloured cement to match incl 10mm thick rendering in cement mortar 1:4 finished rough to recive tiles all as specified and directed.
S&F in repaire Vitreous china white wash down water closet (Pedestal pattern) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc incl P or S trap. complete as specified and directed
S&F chromium plated health faucet with 1 m long pipe complete all as specified and directed.
S&F chromium plated toilet paper holder size 150 x150mm complete all as specified and directed.
S&f in repair PVC valveless syphonic action type low level flushing cistern 10 Ltr. Capacity of approved incl flush pipe of 32mm bore complete all as specified and directed.
S&F in repairs. vitreous china wash basin, white flat back size 550x400mm (excluding taps), incl.CP waste coupling & PVC waste pipe and brackets
S&F in repair for PVC waste pipe of 32/38/40 mm dia and 1000 mm long to WHB, urinal and Kitchen sink complete all as specified and directed.
Taking up or down steel tubing and connection of 15 dia bore complete all as specified and directed.
Taking up or down steel tubing and connection of 20 dia bore complete all as specified and directed.
Cutting chases in brickwall pinning in making good to facings where required and pointing in cement mortar 1:3 to ends and cutting chases for concealed water tubing and making good cutting n.exc. 10 cm girth complete all as specified and directed.
M&L 15mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Refixing old steel tubing and connections in new or old position 15mm dia, complete all as specified and directed.
M&L 20mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Refixing old steel tubing and connections in new or old position 20mm dia complete all as specified and directed.
S&F in repair stop valve, cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore complete all as specified and directed.
S&F in repair Angle valve / stop valve , cast copper alloy fancy type chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore complete all as specified and directed.
S&F in repair Angle valve two way, cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15mm bore complete all as specified and directed.
S&F in repairs Brass CP mixer tap 15mm dia bore (three in one) for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.
S&F in repairs Brass CP mixer basin tap (mixer pillar tap) 15mm dia bore for mixing hot & cold water with lettered HOT and COLD screwed down for iron pipe complete all as specified and directed.
S&F in repairs Bib taps fancy type cast copper alloy chormium plated 15mm bore with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
M&L Brass Chromium plated shower rose 125mm size with or without swivel joints any size including fixing to steel pipe or union incl shower complete all as specified and directed.
S&F in repair Brass chromium plated tubular towel rail 20mm dia,D type, 60 cm long between flanges complete all as specified and directed.
Easing of existing door shutters for easy closing / opening tightening of hinges or changing the position of hinges adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed.
Easing of existing Aluminium door/ window shutters for easy closing / opening or changing glass/ wiremesh/ beads etc, adjustment of shutters etc complete all as specified and directed.
S&F framed work such as grills, grating doors or gates etc. of angle iron, flat iron with ends of bars shouldered and or rivetted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings for terrace, framework of water tanks and similar work confirming to Fe 290 complete all as specified and directed.
M&L for preparetion of new steel surfaces and applying two coats of synthetic enamel paints over a coat of primar with red oxide on new steel surfaces over 10cm width or girth complete all as specified and directed.
M&L one coat of synthetic enamel paints on old steel surfaces over 10cm width or girth after necessary preperation of old surfaces complete all as specified and directed.
M & L for preparation of old painted surface of wood over 10 cm width or girth and applying one coat synthetic enamel paint complete all as specified and directed.
S/F in repairs decorative curtain rod made out of 25 mm dia (outer dia) SS pipe having wall thichness 0.63 mm, PVC coated of any coulor and pattern as approved overall dia 28 to 29 mm, including provn of two nos brackats on each ends and provn of two nos of globe on each ends for each window/door (fancy type) for fixing complete all as specified and directed.
S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
M&L for roof treatment in repair by complete removel of existing old treatment and treated with following specifications :- (a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab. (b) 15 mm thick cement plaster fair finished using cement mortar (1:4) with WPC on roof slab. (c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plastered surface. (d) Applying modified APP polymeric membrane 3mm thick and minimum weight 3.00 Kg / Sqm for water proofing of roof , sealing as directed at site with 100 mm over laps as per manufacture's instruction. (e) Applying two coat of aluminium paint over bituminous surface of membrane. Note : Supply only WPC shall be measured and paid separately under relevant item.
Supply only integral water proofing compound complete all as specified and directed.
S & F Corner Glass Shelf 300 mm (with ABS brackets) of size (300x300)mm complete all as specified and as directed.
S&F in repair soap Dish vitreous china Approx size 160x 160x90mm complete all as specified and directed.
Demolition of cement concrete (un reinforced) of any description incl. floor tile and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Demolition of old decayed / damaged brick work in cement or cement lime mortar and in any condition including removal of same complete all as specified and directed.
Demolition and breaking up 150mm dia drain pipes (saltglazed, stoneware , AC or reinforced concrete) drain pipe, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
M&L for concrete bed for 150 mm bore pipe in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
S & F ultra plus PE, DWC ( Double Wall corrugated ) pipes confirming IS-16098 Part - 2 : 2013 pertaining structured wall plastics pining system for Non - pressure drainage and sewerage 150 mm bore pipe and fittings with non smooth surface, type B complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed.
M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls excluding clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints,laid in trenches or in floors or wall complete all as specified & directed.
M&L PVC (SWR) bend any radius 110mm dia complete all as specified and directed.
M&L PVC (SWR) bend any radius 75mm dia complete all as specified and directed.
M&L PVC(SWR) Tee any radius 110mm dia complete all as specified and directed.
M&L PVC(SWR) Vent cowl 110mm dia complete all as specified and directed.
S&F 110mm dia Branch piece, single (equal or unequal) , ordinary or inverted, spigot or socket type or with parallel branches complete all as specified and directed.
M&L for brick work with sub class "B" bricks straight or curved on plan exceeding 6 mtr mean radius and built in CM 1:4 complete all as specified and directed.
Use and waist form work to soffits of suspended slabs such as roof slabs, floor slabs n.exc.200mm thick in rough finished surfaces etc complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast manhole / septic tanks covers including necessary form work and setting in CM 1:4 complete all as specified and directed.
M&L for mild steel deformed bars 6-8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on any faces brick work including finishing the surface fair and smooth without using extra cement with mixing of water proofing compound complete all as specified and directed.( WPC measured and paid separately)
M&L for providing PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping of manholes and similar work complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation bed of manhole, mass concrete etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) as in channels benching of manhole, laid to shape and slope, surfaces finished even and smooth using extra cement including necessary form work etc complete all as specified and directed.
Cutting into exisiting manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one brick thick honey com walling built in CM (1:4) complete all as directed\.
M&L for Filling of brick bats in soak well laid dry complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down old/unserviceable MCB DB SPN/TPN any capacity by disconnection of electric connection including MCBs,Isolators,etc and making good to disturbed surface complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces.
All as per Ser item No 96 here-in-before but one 3 Pin Socket out let 5 Amps on the same board complete all as specified and directed.
All as per Ser item No 96 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board complete all as specified and directed.
All as per Ser item No 96 here-in-before but one bell/buzzer point controlled by one push button on the independent board complete all as specified and directed.
All as per Ser item No. 96 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size complete all as specified and directed.
All as per Ser item No 96 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
S&F Switch Piano type 2 way switch 5 amp 230 v complete all as specified and directed at Site.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F electric Bell, ding dong type AC 230 Volt single pole complete all as specified & directed.
S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F electronic regulator step type 230 Volts single phase 120 watt complete all as specified and directed.
M&L for lamp holder PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed .
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No- 112 here-in-before but 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire complete all as specified and directed.
All as per ser item No-112 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire complete all as specified and directed.
All as per ser item No-112 here-in-before but 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire complete all as specified and directed.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of incommer and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed at site.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with aluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of Lienear & compact 9 wat LED mirror light with decorative grey end caps,polycarbonate body and ribbed opal diffuser including 2/3 core flexible copper wire with flexible pipe ceiling rose to light fittings complete all as specified and directed.
S&F in replacement of environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity ,comprising of high brightness LEDs, IP54 protection complete with all accessories internally pre-wired and inncluding connecting up with 2/3 core twisted flexible copper conductor cable with suitable size of flexible PVC/steel Conduit complete all as specified and directed.
S&F in replacement of building LED security light fitting 40 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed.
M&L for rewinding repair and greshing of ceiling fan of any size sweep single phase. Ceiling fan of any size opening from any height or any locations, fan opening from hook, clamp & refixing the same after cleaning and greshing with required necessary cutting/welding/granding job or required store such as nuts, bolts, washer and suitable length mild steel/ down rod duly making holes etc complete as specified and directed.
S&F Decorative wall light fitting CT2 10 W made up of polycarbonate, complete all as specified and directed..
S&F for highly efficient LED bulbs, 10 W complete all as specified and derected.
S&F in replacement PVC ventilating air fan single phase 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M/S Sweta Construction
M/S KAMLESHWAR SINGH
M/s Ray construction
M/S SURYA BUILDERS
M/S.R.S.Chauhan and Sons
MS JODHI PRASAD SINGH SONS
96archana ent
M/S RAMOTAR SAHU
M/s Animesh Kumar & Co.
M/s Kundu Enterprises
HARINANDAN RAI SONS
M/S PARAS NATH SINGH
Prativa Enterprises
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .