| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-Finance Lowest and reasonable bid | |
| 2 | L2₹9.6 L+₹1.9 L (23.9%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹11.6 L+₹3.8 L (48.3%)Rejected-Finance BOOTH NO 15 SHOPPING COMPLEX URBAN ESTATE PHASE II JALANDHAR CITY PIN 144022 | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Other than the lowest bid | |
| 4 | L4₹12.3 L+₹4.5 L (58.1%)Rejected-Finance | L4 | Rejected-Finance Other than the lowest bid |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE WEST JALANDHAR CANTT
Kabir Road Jalandhar Cantt.
REPAIR / MAINT OF INTERNAL WIRING OF OFFRS ACCN AT BHIM RD FAFA UNDER GE (WEST) JRC
2024_MES_666581_1
GE/JAL(W)-43/2024-25
Open Tender
Civil Works
Item Rate
180 days
JALANDHAR CANTT
Class E Category b(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
GE WEST JALANDHAR CANTT
₹30,000
Yes
27 Sept 2024
18 Jul 2024
17 Sept 2024
18 Jul 2024
12 Sept 2024
31 Jul 2024
Amount
Taking down carefully aluminium / copper point wiring (light / fan / socket or power)/power wiring complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors Note : (i) The existing conduit of concealed wiring will not be removed from site and same will be reused for point wiring under respective item hereunder.(ii) The qty of serviceable/ unserviceable items will be ascertained by the BOO detailed by GE and serviceable items (such as LED fittings/LED tube and bulb /ceiling/ Exhaust Fans and geysers) will be refixed under respective item hereunder and unserviceable items such as switches, sockets, ceiling rose, holders, brackets, bulkhead fittings, LED fittings, MCB DBs, sunken boxes and fixtures etc. shall be issued to contractor under schedule of credit all as specified and directed.
Taking down unserviceable Submain/ Cable/ Service wire of any size as directed by Engineer-In-Charge.
Taking down main switch / DB as directed by Engineer-In-Charge.
M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of MODULAR TYPE switch/sockets and regulator and including modular type cover plate white colour all as specified and directed for: One light / fan / call bell point controlled by one, one way switch.
One 3 pin socket out let 5 Amps on same board with other switches.
One 3 pin socket out let 5 Amps on Independent board with other switches.
All as per Ser item No.4 above but with 2.5 sqmm multistranded copper multistranded conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board
M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into existing PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. One light / fan / call bell point controlled by one, one way switch.
All as per Ser item No. 8 above but for 5 amps socket on independent board
All as per Ser item No.8 above but for 5 amps socket on same board
S & F switch MODULAR 6 Amps, flush button type, SP, one way, 230 Volts, AC
S & F switch MODULAR 16 Amps, flush button type, SP, one way, 230 Volts, AC
S & F socket out let multipurpose MODULAR 5 pin 6 Amps, flush type, 230 / 250 Volts
S & F socket out let multipurpose MODULAR 5 pin 6/16 Amps, flush type, 230 / 250 Volts
S & F MODULAR fan regulator step type 120W, 02 module complete all as specified and directed.
S & F MODULAR Bell Push 06 Amp 01 module complete all as specified and directed.
S & F switch Piano 5 Amps, flush button type, SP, one way, 230 Volts, AC
S & F socket out let multipurpose 5 pin 5 Amps,230 Volts
Supply and Fixing stepped socket type electronic fan regulator and connecting up complete all as directed by Engineer-In-Charge.
M & L Bell ding dong type AC 230 V complete all as specified and directed.
M & L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 4 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of 20mm in size complete with all accessories alongwith provn of 4 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of 25mm in size complete with all accessories alongwith provn of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.
M & L for sub main wiring with four single core PVC insulated and unsheathed cable 10 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of suitable size complete with all accessories alongwith provn of 2 run of 10 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.
Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus all as specified and directed.
Supply and fix MCCB 63 Amps 4 pole 415 Volt,25 KA breaking capacity .
Supply and fix MCB DB, TPN 4 way double door with suitable 200 amps rated bus all as specified and directed.
S/F MCB TPN 40 Amps 415 volts complete all as specified and directed.
Supply and fix DB,double door, SPN 4 way for MCB, 240 volt with 200 amps rated bus bar.
S/F MCB SPN 40 to 63 Amps 240 volts
S/F MCB SP 6-32 Amps 240 volts
Supply and Fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of cap 20A complete all as specified and directed.
S& F in replacement LED tube set (fitting) 20 W use and through type with internal surge protection device of 4 KV with voltage band 140-280V with LED rod with fixture box type and making electrical connection to ceiling rose all as directed
S&F LED mirror light 10Watt 2 feet complete all as specified and directed.
Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply & fixing in replacement LED Bldg security light fitting 35 Watt including LED lamp pressure die cast aluminum IP66 with surge protection device of 10KV, IK7 LED (SEOUL) 6500K and connecting electrical to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50 mm 3 core including GI pipe 32mm light grade 0.9 Mtr long bent to L shape in 02 Nos of GI Clamps of size 25x6 mm of length 25mm with nuts, bolts and washers complete complete all as specified and directed.
Supply and Fix PVC Conduit pipe Heavy Grade of size 20 mm with all accessories like (Bend/Tee/Junction box) complete all as specified and directed.
Taking down existing Ceiling fan/Exhaust fan capacity/type carefully and refixing the same complete all as specified and directed.
Taking down existing Geyser any capacity/type carefully and refixing the same with replacement of PVC connection/Steel connection and anchor fastener pipe if required complete all as specified and directed.
Taking down existing electric/electronic energy meter any capacity/type carefully all electric wire/submain complete and refixing the same, incl electric connection with new gutties/anchor fastener if required complete all as specified and directed.
M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I
CHOUDHARY AND SONS (BID ID -3084132)
B.P CONSTRUCTION CO (BID ID -3094140)
B D BATRA AND SONS (BID ID -3094690)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .