Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹4.4 LAdmitted-Finance | Admitted-Finance | |
| 2 | ₹5.4 LAdmitted-Finance | Admitted-Finance | |
| 3 | ₹5.4 LAdmitted-Finance | Admitted-Finance | |
| 4 | ₹5.5 LAdmitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance | |
| 5 | ₹5.9 LAdmitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company | HYDROCON ENGINEERS | R K CORRUGATEDBOX AND ALLIED PRODUCTS | Avon Electricals | Raj Engineering Co. | MITTAL TRADING COMPANY |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1600MM x1800x375MM. Having following components of approved make. | 1 | Nos. | 1,35,000 ₹1,59,300 | 3,08,000 ₹3,63,440 | 1,25,000 ₹1,47,500 | 1,22,000 ₹1,43,960 | 63,000 ₹74,340 Lowest | 1,25,000 ₹1,47,500 |
| 2.00 | MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,400Amp with spreader & Handle - Make L&T/siemens | 1 | Nos. | 22,640 ₹26,715.2 | 9,500 ₹11,210 Lowest | 12,500 ₹14,750 | 18,000 ₹21,240 | 23,800 ₹28,084 | 35,000 ₹41,300 |
| 3.00 | MCCB 415V, TP 3phase High breaking capacity 50Hz,125Amp with spreader& Handle - Make L&T/Siemens | 3 | Nos. | 29,610 ₹34,939.8 | 16,500 ₹19,470 | 26,997 ₹31,856.46 | 22,500 ₹26,550 | 14,100 ₹16,638 Lowest | 30,000 ₹35,400 |
| 4.00 | MCB Single pole 6Amp. Make L&T/Havells | 6 | Nos. | 1,080 ₹1,274.4 | 1,500 ₹1,770 | 810 ₹955.8 Lowest | 1,050 ₹1,239 | 960 ₹1,132.8 | 1,200 ₹1,416 |
| 5.00 | MCB Triple pole 63Amp. Make L&T/Havells | 2 | Nos. | 3,640 ₹4,295.2 | 4,000 ₹4,720 | 4,500 ₹5,310 | 3,600 ₹4,248 | 2,700 ₹3,186 Lowest | 6,000 ₹7,080 |
| 6.00 | MCB Triple pole 32Amp. Make L&T/Havells | 2 | Nos. | 2,700 ₹3,186 | 4,000 ₹4,720 | 3,800 ₹4,484 | 3,200 ₹3,776 | 1,900 ₹2,242 Lowest | 6,000 ₹7,080 |
| 7.00 | Over load relay 60-100Make: L&T/siemens | 4 | Nos. | 14,064 ₹16,595.52 | 10,000 ₹11,800 Lowest | 18,000 ₹21,240 | 26,000 ₹30,680 | 15,600 ₹18,408 | 16,000 ₹18,880 |
| 8.00 | Over load relay 6-10 Make: L&T/siemens | 2 | Nos. | 2,100 ₹2,478 Lowest | 5,000 ₹5,900 | 7,000 ₹8,260 | 3,800 ₹4,484 | 3,800 ₹4,484 | 7,000 ₹8,260 |
| 9.00 | Digital Amp. Meter Make AE/L&T | 6 | Nos. | 5,100 ₹6,018 | 9,000 ₹10,620 | 8,700 ₹10,266 | 7,200 ₹8,496 | 5,280 ₹6,230.4 | 4,800 ₹5,664 Lowest |
| 10.00 | Digital Volt Meter0-500V -Make AE/L&T | 1 | Nos. | 850 ₹1,003 | 1,500 ₹1,770 | 1,350 ₹1,593 | 1,200 ₹1,416 | 880 ₹1,038.4 | 800 ₹944 Lowest |
Tender Value
Refer Docs
EMD Value
₹15,600
Closing Date
25 Jul 2025, 2:00 pmClosed
EXECUTIVE ENGINEER (EM) M-10
GREATER KAILASH, PART-I, NEW DELHI
Improvement/Renovation of Main LT panel at Sec-01 BPS in R.K Puram AC-44.
2025_DJB_275650_23
NIT No. 7/EE(EM)M-10/(25-26)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (EM) M-10
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹15,600
Yes
18 Sept 2025
18 Jul 2025
25 Jul 2025
18 Jul 2025
25 Jul 2025
18 Jul 2025
LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1600MM x1800x375MM. Having following components of approved make.
MCCB 415V, FP 3phase High breaking capacity 50KA 50Hz,400Amp with spreader & Handle - Make L&T/siemens
MCCB 415V, TP 3phase High breaking capacity 50Hz,125Amp with spreader& Handle - Make L&T/Siemens
MCB Single pole 6Amp. Make L&T/Havells
MCB Triple pole 63Amp. Make L&T/Havells
MCB Triple pole 32Amp. Make L&T/Havells
Over load relay 60-100Make: L&T/siemens
Over load relay 6-10 Make: L&T/siemens
Digital Amp. Meter Make AE/L&T
Digital Volt Meter0-500V -Make AE/L&T
Motor protection Relay Make: L&T/Siemens
Power contactor 220V 3phase110Amp. Make L&T/siemens
Power contactor 220V 3phase25Amp. Make L&T/siemens
Star delta timer on delay make: L&T/Siemens
Indicating lights LED type RYB & On/OFF. Make : L&T /Havells
Current Transformer200/5,30/5Make AE /Advance/Saviour
Current Transformer400/5 Make AE /Advance/Saviour
On load change over switch 400Amp. Open execution type Make:L&T
Fitting of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hard wares complete in all respect.
Loading, unloading by crane or heavy labour and cartage up to site cleaning & dressing the surface for Installation of the panel at site on base frame ,laying of cable ,termination of cable both incoming & out going side
Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as follow Continuity and earth testing Meggaring of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. checking for all tightness of nut and bolts Alignments of doors etc. Interlocking tests. All function tests
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .