| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | ₹16.5 L Quoted ₹16.8 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹20.9 L+₹4.1 L (24.3%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹20.9 L+₹4.1 L (24.3%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹21.5 L+₹4.7 L (27.9%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | ₹21.5 L+₹4.7 L (27.9%) | L3 | Rejected-Finance HIGHER BIDDER |
| 4 | L4₹22.2 L+₹5.4 L (31.9%)Rejected-Finance | ₹22.2 L+₹5.4 L (31.9%) | L4 | Rejected-Finance HIGHER BIDDER |
| 5 | L5₹23.2 L+₹6.4 L (38.1%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹23.2 L+₹6.4 L (38.1%) | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
7 Jun 2021, 6:00 pmClosed
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8361/E8
2021_MES_446753_1
8361/E8
Open Tender
Civil Works
Item Rate
30 days
VASCO
Class E Category a i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹38,000
Yes
23 Jun 2021
29 May 2021
9 Jun 2021
29 May 2021
7 Jun 2021
1 Jun 2021
29 May 2021 - 1 Jun 2021
Amount
Dismantling/Taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled as directed by Engineer-in-Charge.
M & L rendering 10mm thick (avg) on concrete surfaces over roof slabs, in cement mortar 1:4, mixed with liquid water proofing compound, finished even and smooth without using extra cement, to receive roof treatment complete all as specified and as directed. (Note: - water proofing compound shall be measured and paid separately)
Supply only waterproofing compound.
M&L APP based polymeric membrane minimum veight 3kg/sqm and minimum 3mm thick reinforced with polyster non- woven fabric (wt. not less than 150gms/sqm) laid on primed surface by torch application method with minimum side overlap 100mm and 150mm as end lap over roofs after cleaning the surfaces properly with water and allowed to dry completely including priming surfaces for applying heavy treatment complete all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Fillig the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant in Sika/ Fosroc/ BASF) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat or equivalent in Sika/ Fosroc/ BASF without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely.
Immediately apply the second coat with a roller, to eusure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self-tapping screws all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws all as specified & directed.
Dismantling mild steel work of any description not otherwise provided for
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails, wind tie and framings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confrming to Fe 410-W including cleats, distance pieces etc
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including frame work cover fillets
M & L providing Aluminium (powder coated) snap grid frame work in repair for false ceiling of grid size 605 mm x 605 mm complete all as specified and as directed.
M & L 12mm thick Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid. (Note:- Aluminium grid shall be measured seperately under relevant item of this Schedule.)
M & L 12mm thick Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid fixed in repair. (Note: Aluminium grid shall be measured seperately under relevant item of this Schedule.)
Disconnecting existing water tanks of size exc. 250 ltr but n.exc. 500 Ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc
All as per item No.16.00 above but of size exc. 500 ltr but n.exc. 1000 Ltr capacity.
Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes etc. of capacity exc. 250 ltr but n.exc 500ltr and refixing in position.
All as per item No.18.00 above but of size exc. 500 ltr but n.exc. 1000 Ltr capacity.
S & F in repairs Ball brass valves 15mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed.
Taking up/down old GI tubing and connection of size 15mm bore, including cleaning for refixing, complete all as specified and as directed.
Taking up/down old GI tubing and connection of size 20mm bore, including cleaning for re-fixing, complete all as specified and as directed.
Supplying and laying of CPVC water tubing 15mm bore, (20mm outer dia) SDR-11 grade with all fittings and fixed complete to wall/Ceilings or laid in floors all as specified and as directed.
Supplying and laying of CPVC water tubing 20mm bore, (25mm outer dia) SDR-11 grade with all fittings and fixed complete to wall/Ceilings or laid in floors all as specified and as directed.
Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs
Dismentaling water tanks and removing to store exc 250 and n.exc 500 ltrs
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position inc 20mm bore PVC float valve all as specified and directedin SSR Pt I
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position inc 20mm bore PVC float valve all as specified and directedin SSR Pt I
S & F in repair Steel rolling shutters, 1.25 mm thick of laths, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type
Ball bearing for rolling shutters
Preparation of new steel surfaces and applying two coat of aluminium paint over a coat of aluminium redoxide primer
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.
Taking down cement plastering of any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
M & L for preparation of new surfaces walls and applying two coat of acrylic anti-fugal weather proof exterior grade paint of first quality over a coat of primer incl sealing the cracks all as specified in manufacturers instruction Make STP Ltd (Shallcry - 215)/ Asian Paint (Ultima stretch)/ Berger Paint (Weather coat long) all as specified and as directed.
M&L rendering 10 mm thick in CM 1:6 on concrete solid block wall surface finished even and smooth without using extra cement.
M&L for preparation on newly plastered surface of wall for painting and applying 3 mm thick wall care putty on plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting.
M & L for applying one coat of synthetic enamel paint on old treated surface of steel and iron surfaces over 10 cm width or girth including prepartion of surface complete all as specified and as directed.
M & L for prepartion of new surface of steel or iron surfaces over 10 mm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M & L for complete removal of existing treatment and preparation of old surfaces of ceiling and applying two coat of distemper oil emulsion over 3mm thick wall care putty complete all as specified and as directed.
M/S jvsr constructions
M/S P S BABU
K M SUBHANAIAH
M/s J.D. DESAI
M/S G.N.POWAR
M/S Kartik Enterprises
M/S DUBAL CONSTRUCTION
pk janardhanan
Super Construction
M/s. P S REDDY
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .