COMPOSITE WORK OF MOTHER STATION AT ASTC BISWANATH CHARIALI
2025_ICD_49741_1
NEGDCL/MS-BISWANATH/2025-26/08
Open Tender
Composite Works
Works
Biswanath Chariali
Please refer Tender documents.
2 documents required · 2 mandatory
₹9,500
₹9.6 L
Yes
Online
12 Mar 2026
30 Dec 2025
20 Jan 2026
30 Dec 2025
20 Jan 2026
12 Jan 2026
8 Jan 2026
MS BISHWANATH, ASSAM
FABRICATION, ERECTION, INSTALLATION AND TESTING OF PIPING
Size-2 Inch, 300# Thk/Sch-XS, Material-ASTM A106 Gr B (CHARPY), BE, Seamless,Dimension Std.-B 36.10
Size-2 Inch, 150# Thk/Sch-XS, Material-ASTM A333 Gr 6, BE, Seamless,Dimension Std.-B 36.10
INSTALLATION OF VALVES
Installation, Calibration and Commissioning of Above Ground Butt Weld Ends DGAV Ball Valves, DGAV Actuator & Normal Ball Valve (BW) as per Standard Specification, Data Sheets, P & IDs as per details given below:
Installation of above ground Flanged Valves (Ball / Plug / Check / Gate / Globe) as per details given below:
Size-4 Inch, Rating-300#
Size-2 Inch, Rating-300#
Installation of above ground Butt Welded Valves (Ball / Plug / Check / Gate / Globe) as per details given below:
Size-2 Inch, Rating-300#
Installation of Insulating Joint as per details given below:
Supply including procurement and transportation to worksite(s)/workshop(s) including loading, unloading and handling for the following materials to be supplied by Contractor as per the requirement of PMS, specifications, data-sheets, standards, instructions of Owner/ Engineer-in-Charge and other provisions of Contract.
FLANGES
Supply of Weld Neck Raised Face (WNRF) Flanges as per details below:
Size-2 Inch, 300#, Thk/Sch-XS, Material-ASTM A105 (CHARPY), Face/Finish-300, RF/125AARH, Dimension Std.-ASME B16.5
Size-2 Inch, 300#, Thk/Sch-XS, Material-ASTM A105 (CHARPY), Face/Finish-300, RF/125AARH, Dimension Std.-ASME B16.5,with JS Holes
Size-2 Inch, 150#, Thk/Sch-XS, Material-ASTM A350 GR.LF2, Face/Finish-150, RF/125AARH, Dimension Std.-ASME B16.5
Supply of Blind Flanges as per details below:
Size-4 Inch, 300#, Material-ASTM A105 (CHARPY), Face/Finish-300, RF/125AARH, Dimension Std.-ASME B16.5
Size-2 Inch, 300#, Material-ASTM A105 (CHARPY), Face/Finish-300, RF/125AARH, Dimension Std.-ASME B16.5
Supply of Spacer and Blind /Fig 8/ Spectacle Blinds per details given below:
Size-4 Inch, 300#, Material-ASTM A105 (CHARPY), Face/Finish-300, FF/125AARH, Dimension Std.-ASME B16.48
Size-2 Inch, 300#, Material-ASTM A105 (CHARPY), Face/Finish-300, FF/125AARH, Dimension Std.-ASME B16.48
FITTINGS
Supply of R=1.5D, 90° BW Elbow as per details given below:
Size-2 Inch, Thk/Sch-XS, Material-ASTM A234 Gr.WPB, (CHARPY), Dimension Std.-ASME B 16.9
Supply of R=1.5D, 45° BW Elbow as per details given below:
Size-2 Inch, Thk/Sch-XS, Material-ASTM A234 Gr.WPB, (CHARPY), Dimension Std.-ASME B 16.9
Supply of BW ReducingTee/Equal Tee as per details given below:
Size-2 Inch x 2 Inch Thk/Sch- XS x XS , Material - ASTM A 234 Gr. WPB, (CHARPY) Dimension Std.-ASME B 16.9 300#
Supply of Sockolet as per details given below:
Size-4 Inch X 3/4 Inch, 6000#, Material-ASTM A105, Dimension Std.-MSS-SP 97, SW
Size-2 Inch X 3/4 Inch, 6000#, Material-ASTM A105, Dimension Std.-MSS-SP 97, SW
Supply & Installation of Reducer
Supply of Piping as per details given below:
Size-2 Inch, 300# Thk/Sch-XS, Material-ASTM A106 Gr B (CHARPY), BE, Seamless,Dimension Std.-B 36.10
Size-2 Inch, 150# Thk/Sch-XS, Material-ASTM A333 Gr 6, BE, Seamless,Dimension Std.-B 36.10
RADIOGRAPHY:
Performance of radiographic inspection of piping of all types, sizes, thickness including providing or hiring of all necessary equipment, supply of all consumables including radiographic films and whatever else even though not expressly mentioned but required to perform the work as per specification and instructions of Engineer-in-Charge. Contractor to submit DPR, Inspection Report along with Radiography Report to Engineer-in-Charge. Note : a) All NDT including Radiography, MPT, LPT for below 2" are covered under this SOR item. No separate payment shall be made. Radiography of piping joints as per details given below:
Size-6 Inch
Size-4 Inch
Size-2 Inch
PIPE SUPPORTS
Supply, fabrication and erection of pipe/ equipment supports (for all sizes/ thickness) including shoes, pipes etc. as required, cradles, turn buckles, T-posts for all types of guides, anchors, special supports for cold/hot insulated pipes etc. if applicable, all necessary equipment, consumables, labour etc. for completing all works including supply of bolts, nuts, washers, U-clamps, wooden blocks etc. as required for supporting, supply and application of paints and primers suitable for normal corrosive painting environment as defined in contract document and as per standard specification for painting specification no. VPC-SS-PI-0008, Drawings, Specification, Standards, other provisions of Contract and instruction of Engineer-in-Charge.
MS Structural Steel
PAINTING
Painting of all above ground piping including all fittings, valves, flanges etc. and including colour bands
Size-4 Inch, Painting Environment-Corrosive Normal Environment (Above Ground)
Size-2 Inch, Painting Environment-Corrosive Normal Environment (Above Ground)
PIPING LEAKS / BURSTS (ATTRIBUTABLE TO OWNER)
SUPPLY OF RAIN CAP
Supply and Installation of Rain Cap including all necessary fabrication works, including providing all necessary equipment's, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, data sheet, specifications enclosed with the Contract and directions of Engineer-in-Charge.
4" Rain Cap for Vent, 15HLT
Nitrogen Supply
Supply of Nitrogen with cylinder for localized purging, Hook up of pipeline and piping.
INSTALLATION OF MECHANICAL EQUIPMENTS
SINAGE BOARDS
Supply and installation of Aluminum composite panel board all support structural/fixtures at all heights painted with two coats of first quality synthetic enamel paint over two coats of Zinc phosphate primer of approved make, concrete grouting in 1:2:4, wherever required complete in all aspects as per following specifications, size, shape and as directed by In-Charge. Board Material : Aluminum composite panel ( Alucobond, Alpolic, Renybond 3mm/ 0.3 mm thick PVDF coated French Blue No. 166 (IS -5) Lettering : 3M vinyl 3630 series Border : L pipe, Aluminum ; Powder coated Laminate : 3M 8519 series laminate film Note: The matter/drawing to be printed shall be provided in soft form as Doc/ PDF/Dwg file. Conversion required if any for making the files printable shall be in vendor's scope.
SLOGAN PAINTING
Painting of slogans/ boards/ lettering on plastered wall/ MS boards, AC sheets etc. at heights as indicated below as directed at site. Rate to include for all scaffolding, staging, supply and providing of required colour 1st quality synthetic enamel paint for the letters as well as the back ground. Paint area measured once shall be considered for payment purpose.(Visual Identity designs as per Visual Identity manual) at all heights
POLIHED GRANITE FACIA
Providing and laying mirror polished Black granite 20mm thk over Front wall including engraving NEGDCL Logo and lettering using stainless steel letters. Each granite facia shall be minimum 3.2 sq. mt. (2 by 1.6 m approx.).
INTERNAL SIGNAGE BOARDS
Supply and Installation of Mandatory Signs made of 3mm ACM Sheet and Printed on ECO Vinyl Sheet 300x100 mm. Detail specification as given in Tender
Supply, Installation, commissioning of Eye/Face wash and safety shower with Pedal, made of Galvanized Iron material as instructed by Engineer-in- Charge.
Supply, Laying, testing & commissioning of SS Tubes, SS Fittings & SS Valve as per technical specification, typical P&ID, drawing, scope of work including SS tube installation, hydrotest at site & as per instruction of Engineer in charge.. Laying Including with Clamps & Supports as per instruction of Engineer in charge
SS Tubes
¾”OD X 0.095” min Wall thk.,Material SS316 SS Tube
½”OD X 0.083” min Wall thk.,Material SS316 SS Tube
Conductive Core Thermoplastic Hose
Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Union
Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Reducing Union
Equal Tee
Size:¾" OD x ¾" OD x ¾" OD, Material : SS316 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Reducing Union Tee
¾" OD x ½" OD x ¾" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Tube End Connection
½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Front Ferrule
3/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Back Ferrule
3/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Male Connector
Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Size 1/2” NPT (M) x 3/4” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
SS Ball Valves
2-Way Trunioun Normal Bore Ball Valve ¾"(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
2-Way Trunioun Normal Bore Ball Valve ½"(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
3-Way Trunnion Mounted, Reducer Bore Ball Valve ½" OD end Connection and ¼” NPT (F) bottom end connection(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC
SS Nut Ferrule
SS Nut 3/4" OD SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
SS Nut 1/2” OD SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
Fire fighting Equipments
75 kg capacity DCP type (trolley mounted)
9 kg capacity DCP fire extinguisher
4.5 kg capacity CO2 fire extinguisher
Supply and installation of mandatory signs made of 3 mm ACM sheet and printed on ECO Vinyle sheet
Wind Sock
SECTION-B : Civil Work
i) For all depths below and upto & inclusive of plinth level.
ii) For all heights above plinth level.
PLASTERING WORK
PAVER BLOCKS Flooring
UPVC DOORS & WINDOWS WORK
UPVC DOORS Providing and fixing of uPVC Door size 2100 mm x 1200mm and 2100 mm x 750 mm of wall thickness 1.2mm ± 0.25mm made out of extruded section plain uPVC sections. The Door frame made out of rigid uPVC sections meter cut at 4 corners & joint with plastic fusion welding with internal reinforce required. The shutter section made out of extruded rigid uPVC with internal reinforced with provision of 5mm glaze/wire mesh as per requirement. The door shall be fixed to the wall using 65x100mm long M.S. fasteners at suitable place provided for each vertical and horizontal member etc. complete as per manufacture’s specification and direction of Engineer-in-charge.
UPVC WINDOWS Providing and fixing of uPVC Window, size 1200mm x 1600mm of wall thickness 1.2mm ± 0.25mm made out of extruded section plain uPVC sections. The window frame made out of rigid uPVC sections meter cut at 4 corners & joint with plastic fusion welding with internal reinforce required. The shutter section made out of extruded rigid uPVC with internal reinforced with provision of 5mm glaze/wire mesh as per requirement. The window shall be fixed to the wall using 65x100mm long M.S. fasteners at suitable place provided for each vertical and horizontal member etc. complete as per manufacture’s specification and direction of Engineer-in-charge.
HANDLE BAR Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 100 mm long with SS screws etc. complete as per direction of the Engineer-In-Charge. Anodized (AC 15 ) aluminium tubular handle bar.
BRASS TOWER BOLTS Providing and fixing 100 mm x10mm bright finished brass tower bolts (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
NORTICE LATCH AND LOCK Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
礀ࠀ䥗䑎坏䘠十䕔䕎倊潲楶楤杮愠摮映硩湩
WATER SUPPLY & SANITARY
Providing and fixing PVC water tank of approved make with ISI mark and conforming to IS 12701 and with GI fittings for inlet, outlet, Over flow, scour float valve, connections of required size and dia. Including connections and hoisting/fixing the same tank on roof and other places at all heights with all bye-works complete at all leads and lifts as per drawings, specifications and instructions of the Engineer Incharge. (Support of tank on brick/RCC/PCC will be paid under relevant items)
a) 1000 litres capacity
Supplying, fitting and fixing white glazed vitreous china wash basin of superior quality - HSW No. 10032 model or equivalant with ISI mark and size 550mm x 430mm, having single or double holes with 15 mm CP brass pillar tap - JAQUAR Continental series No. 011, CP brass chain and plugs, 32mm CP brass waste coupling, PVC flexible waste pipe, 15mm PVC inlet water pipe connection, CI cantilever brackets embedded in 1:2:4 concrete, 15 mm CP brass angle stopcock - JAQUAR Continental series No. 053, etc. filling the gaps between basin and wall with white cement etc. all complete at all leads and lifts as per drawings, specifications and instructions of the Engineer-In-charge.
Supply and fixing of Floor trap with SS grating to waste water pipe connection.
1) 75mm dia of weight not less than 4.8 Kgs.
Providing and fixing white glazed vitreous china large flat back, channel flushing, front lipped standing urinal size 590x375x390mm of superior quality from approved make (similar to HSW No. 60002 model with ISI mark,with push valve, 15 mm PVC flexible inlet connection, 15mm CP brass angle cock, 15mm dia CP brass spreaders connceted to matching connecting pipe from cistern and 32mm dia PVC waste pipe upto floor all as per directions of the Engineer-In-charge (partitions excluded).
Providing and fixing 5 mm thick translucent white acrylic plastic sheet with table rubbed, edges rounded and polished, of size 75x50 cm, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Providing and fixing 15mm CP brass long body bib cock with wall flange - JAQUAR Continental series No. CON-047KN or equivalant at all leads and lifts as per drawings, specifications and instructions of the Engineer-In-charge.
Providing and fixing 15mm CP brass concealed stop cock (extra heavy body) with adjustable wall flange - JAQUAR Continental series No. CON-087KN or equivalant at all leads and lifts as per drawings, specifications and instructions of the Engineer-In-charge.
Providing and fixing 15mm CP brass angular stop cock - JAQUAR Continental series No. CON-059KN or equivalant at all leads and lifts as per drawings, specifications and instructions of the Engineer-In-charge.
Providing and fixing CP brass health faucet with 8mm dia, 1m long flexible tube and wall hook with NRV- JAQUAR Allied series No. ALD-CHR-577 or equivalant at all leads and lifts as per drawings, specifications and instructions of the Engineer-In-charge.
Providing minimum 6mm thick polished float glass mirror, bevelled edge, of approved make fixed to with 6mm thick marine plywood sheet backing with teakwood beading, fixing arrangements all complete at all leads and lifts as per drawings, specifications and instructions of the Engineer-In-charge.
Mirror size- 750x450mm
Providing and fixing recessed toilet paper roll holder including roller white glazed vitreous china, HSW No. 40.025 or approved equivalent make
Providing and fixing CP brass towel rail 600mm long, 20 mm dia with CP brackets fixed to wall with SS screws and TW guttas.
brick masonry inspection chamber Construction of brick masonry inspection chamber with full bricks, in CM 1:5, provided with a light duty CI covers conforming to IS:1726, matching size, weight not less than 52 kg, embedding the CI frame in 100 mm thick RCC top slab, neatly finished including 12mm thick plastering on both faces in CM 1:6, rounding, float coat of neat cement finish on the inner side, PCC bedding etc., all complete including excavtion and backfilling, shuttering, painting the frame and cover with two coats of approved anti corrosive paint etc., as per specifications and direction of Consultant.
Internal size 450x450
Gully Trap Providing yard gully trap 150x100mm with CI grating 150 x 150mm and water tight light weight CI covers conforming to IS:1726 of size 300x300mm including half-brick masonry in CM (1:4) plastered neatly with CM (1:4) on both faces, 100mm thick PCC bed of mark M-10C, necessary excavation, complete as per direction of the Consultant.
Gate Valve Supplying, fitting and fixing superior quality gun metal gate valve (full way) of "LEADER" make or equivalent with ISI mark
a) 32mm dia
MISCELLANEOUS WORK Providing and laying stone ballast 40 to 115 mm size in layers upto 200mm thickness (wherever not covered in respective SOR items) with spreading & blinding material like sand, stone grit and compaction with mechanical means, watering etc. under floors/foundations, plinth protection & as per drawings including cost of material complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge.
SEPTIC TANK Providing and construction of septic tank in brick masonry and base and top slab in RCC M25 complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge.
BORE WELL Supply, laying, drilling and commissioning of G.I Bore well of 150mm Diameter and upto 100m depth including submersible pump with all accessories, panel, wiring and all other works required to make it operational all complete in all respects as per scope of work and directions of the Engineer-in-charge. Note: 1. Rate to include cost of all labour, tools, tackles, equipment, hire, charges, supply of all materials including pipes, water meter, valves, boring, priming, cabling, pumps, clearing, earthwork, etc. with all bye works and sundry works and consumables. Supply, installation, testing and fixing of Single phase, 1.5 HP sub-mersible pump-cum motor of approved make capable of delivering 300 Litre Per Minute (LPM) to required head with starter, wiring (3 core X2.5 Cu flat cable- 60m) from starter to motor and incoming feeder to starter i.e. spot welded plate for borewell top, M.S clamps at top of casing/housing pipe, Bail plug/bottom plug, complete in all respects inclusive of cost of all labour, materials, tools, tackles, etc. as per drawings, specifications and directions of the Engineer-in-Charge.
Stone Boulders (Filter media) Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, Gravels of 5mm to 10mm and coarse sand of size range 1.5mm to 2mm (each in equal quantity) in recharge pits and required size gravel in the borewell, in the required thickness, for all leads & lifts, all complete as per detail drawing and direction of the Engineer-In-Charge.
BUILDING DRAINAGE, PLUMBING & SANITARY
RAIN WATER SPOUT AND PIPES supplying and fixing on wall face unplasticised-Rigid PVC rain waterpipes conforming to IS:13592 Type A including jointing with seal ringconforming to IS:5382 leaving 10mm gap for thermal expansion.(i) SingleSocketed pipes. 110 mm dia pipe
P.V.C. waste pipe Providing and fixing 32 mm diameter flexiple P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete :
MANHOLE Construction as per standard drawing of brick masonry (brick class shall be as mentioned below) inspection chambers/manholes of 750mmx750mm internal size 1000mm deep(Max.) in cement mortar 1:4 (1 cement: 4 sand) with CI frame and cover 500mm clear dia, (circular Medium duty of grade MD-10) conforming to IS:1726 fixed on RCC slab of M-30 grade, necessary excavation, supplying, fixing 4 Nos. 16mm dia M.S. rungs, M-20 grade foundation concrete 1:3 cement mortar(1 cement: 3 sand) plastering of 13mm average thickness for inside & 16mm avg. thickness for outside exposed surfaces, backfilling, disposal of surplus earth upto a lead of 100M, benching with M-20 grade cement concrete and rendering smooth with a neat coat of cement slurry, painting the C.I. frame and cover with two coats of chlorinated rubber zinc phosphate primer @ 40µ DFT per coat and finish painting consists of two coats of chlorinated rubber paint @40µ DFT per coat etc. all complete as per drawings, specifications and directions of Engineer-in- Charge.
STONE WARE PIPES-100 MM Stoneware Pipe for Sanitation:- Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : a) 100 mm diameter
STONE WARE PIPES-150 MM Stoneware Pipe for Sanitation:- Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : a) 150 mm diameter
Pillar Cock Cost of providing and fixing pillar cock long neck with aerator. Jaguar or approved equivalent fixed with necessary accessories.
C.P Trap Cost of providing and fixing C.P. cockroach trap, floor drains of Chilli / equivalent make.
WATER SUPPLY & SANITARY
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including hydraulic seat cover, and cistern fittings, 'P' or 'S' trap, nuts, bolts and gasket etc complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete, including collars, bends and specials, taking out waste water and solid waste from toilets to the nearest gully trap or inspection chamber including the cost of all material, labour, leads & lifts, transportation, taxes, duties, all as per specifications, drawings and directions of the Engineer-In-charge.
65 mm dia
100 mm dia
150 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. For Internal work exposed on wall
50 mm nominal bore
40 mm nominal bore
32 mm nominal bore
25 mm nominal bore
20 mm nominal bore
15 mm nominal bore
Making soak pit with 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With class 5 bricks
Supply, laying and commissioning RCC pipes of 150/300mm dia NP2/ 450 mm dia NP3/ 600 mm dia NP3 including earth cutting, filling, disposal of surplus earth, bed concrete, RCC pipe, SW gully trap/ chamber, grease trap, all complete in all respects as per scope of work, detailed drawings, technical specification and directions of the Engineer-In-Charge.
150mm dia RCC pipe (NP-2 grade)
300mm dia RCC pipe (NP-2 grade)
450mm dia RCC pipe (NP-3 grade)
600mm dia RCC pipe (NP-3 grade)
Notes: 1. Only net length of RCC pipe laid in RM will be measurable for payment & Manhole provided will not be considered for payment I.e. included in this item.] 2. To be read in conjunction with relevent clause of PJS.
Roof Treatment Providing and applying polyether based polyurethane (PU) waterproof coating consisting of 2 components (resin + hardener) in four coats consisting of a primer adhesion coat and three sealing coats applied by brush evenly to perfect level @ min.160 gm/sq.M per coat over R.C.C. slab including sprinkling the last coat of P.U. with a layer of clean sand (300 micron) and laying min. 50mm thk. PCC (1 cement :2 coarse sand :4 aggregate) over the fully cured coating in panels of max. 1.2M x 1.2M with 24 SWG chicken wire mesh finished smooth and sealing joints between panels with Polysulphide sealant as per approved manufacturers spec. and including preparing the base surface (levelling, cleaning, filling up cracks with thin paste of Polyurethane filling compound) providing fillets of 75mm radius with PCC (1 cement : 2 coarse sand : 4 aggregate) at junctions of horizontal and vertical surfaces, continuing the water proofing on vertical face to a minimum ht. of 150mm over finished roof surface, terminating it in continuous groove of 10mm x 20mm and filling with polyurethane sealent putty, continuing the treatment into rain water outlets by, providing 450mm x 450mm khuras at all outlets, levelled down by min. 25mm, finishing all complete.
Disposal of Dismanteled Material Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for all leads and for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more and disposal beyond 2KM.
SS TUBE TRENCH Providing and Construction of SS tube trench in brick masonry in brick masonry wall of thickness 230 mm and size of cross section of trench (600x(300/600)) over the 100mm thick PCC(1:4:8) base with precast SFRC cover of 600x550x70mm thick along with edge angle(ISA 75x75x6 ) and fixing of ISA 50x50x6 for supporting pipe trays @ spacing of 1000mm c/c aloing the trench, including 12mm in CM 1:5 plasting of walls of trenches complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Enigineer-in-charge.
GOLA Providing gola 75 x75mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement:3 fine sand) as per standard design.
DISMANTLING/DEMOLISHING
Demolishing of Cement Concrete (PCC) of all grades manually/mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
Demolishing of RCC of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
Demolishing of CC block work/brick work / stone masonry of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
Demolishing barbed wire or flexible wire rope in fencing including making rolls and staking as directed by the Engineer.
Providing and fixing Fencing Gates
Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge.
4m Wide x 2.1m High
1m Wide x 2.1m High
Providing and Fixing 6 O/P Chequered Plate Covers Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge. [ Rate to include cost of all labour, nut, bolts, stiffening sections, bars tools, tackles, hire charges, royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
Providing and fixing safety guard Providing and fixing safety guard with 80 mm heavy duty G.I. Pipe ( size 450 deep and 300 width inside) grouted with ready mix high strength grout mortor of approved manufacturer and painted with approved quality paint as per scope of work , detailed construction drawings, technical specifications and directions of Engineer-In-Charge. [Rate to include cost of all labour , tools , tackles etc. complete].
Providing and fixing Colour Coated Sheets Preparation of sheeting drawings, procurement, transportation and delivery at erection site of colour coated steel sheets for roof & side cladding shall be of Galvalume/zincalume BHP steel sheet made of cold rolled steel of 300 MPA minimum yield strength conforming to ASTM A366 or AS 1595. Base metal thickness shall be 0.5mm and total thickness of colour coated profiled sheet shall be 0.58mm. Fixing of sheets with all flashings, corners, ridges, cutting, bending of sheets to a required shape & size and erecting them in roof & sides with all fixing arrangement as per manufactures instructions and complete in all respect as per drawings and specifications. (Net laid area to be measured.)
Providing and fixing Trac ( 150 F ) Pre-Coated False Ceiling System Preparation of sheeting drawings, procurement, transportation and delivery at erection site Trac ( 150 F ) Pre-Coated Steel False Ceiling System with powder coated finishes as per Manufacturers Instructions and Specifications. Notes:- i.) Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as structural steel, purlins, nuts, bolts, washers, screws, seals, wire ropes,flashing,fitting and fixtures,gutter, rain water pipes and bends, electrodes, edge colour coated sheets for signage works,primer, paint and all consumables etc. with all bye works and sundry works complete in all respect. ii.) The quantities indicated are estimated values and hence are approximate. Final payment will be made based on actual quantities to be certified by the Purchaser. iii.) The cost of MS bolts (permanent and service), washers, electrodes, putty, gases, cost of straightening the raw materials, cutting of flats from plates and providing splices, paints, tools, plants, etc., as required for the work shall be deemed to be included in the quoted rates. iv.) All handling and transport charges of raw materials and fabricated structures including double handling, as required, for completion of work in accordance with Time schedule, are deemed be included in the quoted rates. v.) All accessories like MS tower bolts, MS Pivot, MS Wheels, MS Tee section, locking arrangement etc. shall be measured by weight only. Contractor shall ensure proper alignment and smooth operation of Gate.
SECTION-C : Electrical Work
SUPPLY, INSTALLATION, TESTING & COMMISSIONING (SITC)
Electrical Power Distribution Boards (DBs)
MEDB(Main Electrical Distribution Board) - Supply, Design,Manufacturing,Assembly,Inspection,Testing at shop,packing of complete set of Electrical panel suitable for 415 Volt,3 phase neutral,4wire,50Hz,25kA AC supply, system fabricated in compartmentalized fom from CRCA sheet steel not less than 2mm thick, duly treated with 7 tanks process, powder coated with approved shade and oven dried .The complete Electrical panels shall have a short circuit withstand capacity of 25kA for 1 second and IP42 rating.The panel shall have suitable arrangement for transfer to GG during mains failure and vice-versa when mains power is restored .The panel shall have a common copper earth bus of suitable size at the rear with 2Nos. earth studs, design as per drawings and documents, specifications,codes and standards and direction of consultant /owner. Both incomer is to be provided with a suitable Type1+Type 2 SPD. Feeder details are as follows- Incomer-1- 63A, 4P MCCB with μProcessor release Incomer-2- 63A, 4P MCCB with μProcessor release Outgoing- 16A, TP MPCB 02 nos 16A, 4P MCB 04 nos 10A, DP MCB 02 nos 16A, DP MCB 02 nos 20A, DP MCB 02 nos 32A, 4P MCCB 01 Nos 32A 4P MCB 01 nos + 40A 4P Contactor 01 nos with astronomical timer + 5nos 10A DP MCB 32A 4P MCB+32A 4P ELCB+06A DP MCB 03 nos + 10A DP MCB 02 Nos
Automatic Power Factor Correction Panel
Supply, installation, testing and commissioning of automatic power factor correction panel with 4 stage 20kVAR capacitor bank complete with sensing CT and automatic power factor correction relay.The relay shall have the facility for manual operation also.
UPS and UPSDB
Supply, Installation, Testing and Commisioning of single online (1 x100% configuration) 2kVA AC UPS with isolation transformers and solid state voltage stabilizer and static by-pass switch.The UPS shall be suitable for 3 phase 415 volt input and 230 volt, 50Hz, single phase output. UPSDB-Supply, installation, testing and commissioning of complete set of electrical panel suitable for 230V AC supply, 1phase, 2wire, 50Hz, 6kA fabricated from CRCA sheet steel not less than 2 mm thick duly treated with 7 tanks process, powder coated with approved shade and oven dried. Main Power Bus shall be of Copper 63A rating.Incomer 32A 2P MCB with shunt trip 1 no. Outgoing Feeders shall be as follows:4 nos 6A DP MCB and 4 nos 10A DP MCB. The panel shall have a voltmeter and ammeter. The complete electrical panel shall have a short circuit with stand capacity of 6 kA for 1 second, IP 42 rating .The panel shall have a common copper earth bus of suitable size at the rear with 2 Nos. earth studs, design as per drawings and documents, specifications, codes and standards and direction of consultant /owner . The incomer is to be provided with a suitable Type1+Type 2 SPD.
BATTERY BANK
SMF VRLA batteries bank -Supply, Installation, Testing and Commissioning of SMF VRLA batteries bank suitable for 1 hours battery back-up time, complete with all interconnecting cables, glands, battery cables, battery racks, connectors and lugs etc.The battery bank shall be as per specifications Doc No:VCS-SS-EL-4042. Battery sizing shall be done using battery capacity factor (kt), ageing factor (1.25) and design margin of 10%.
POWER CABLES
Supply, laying, termination, testing and commissioning of 1.1 kV grade, XLPE insulated, armoured power cable, control cabkle and signal cable, PVC inner sheathed, FRLS PVC outer sheathed (conforming to IS:7098and specification) of following sizes in trenches /excavated under round trenches /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
3.5Cx35 sq.mm A2XFY (incoming supply)
4Cx4 sq.mm 2XWY (ups and air compressor)
3Cx2.5 sq.mm 2XWY (Lighting loads and other UPS load)
Earthing and Lightning System
Supply, installation, testing, commissioning, transporting to site location of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material and labour as per specification and drawings approved by the company
Supply, installation, testing & commissioning of Conventional Earthing with Perforated GI earth pipe, 3.0 mtr long, 100 mm dia and Minimum 1.6mm Thick including accessories and providing masonary enclosure with CI cover plate having numbering and locking arrangement etc., with charcoal and salt as required as per IS 3043.
Supply, assembling, testing and commissioning all the items for constructing Cu plate earthing station comprises of Earthing with copper earth plate 600 mm X 600 mm X Minimum 3.15 mm thick including accessories, and providing masonry enclosure with CI cover plate having numbering and locking arrangement and PVC watering pipe of 50mm dia 2.7 metre long etc.with charcoal/ coke and salt as required.
GI Strip(50x6)mm
GI Strip(25x3)mm
Copper Strip(25X3)mm
Supply, installation, testing & commissioning of lightning conductor finial made of 25mm dia 300 long GI tube having single prong at top with 85 mm dia 3 mm thick GI base plate including holes etc complete as required. 25x3 mm copper strip for lightning protection will be from same item above
Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC and other item etc.
Providing and fixing 16 way G.I Earthing plate For Earthing strip Termination
STREET LIGHTING POLES and OUTDOOR LIGHTING
Supply, installation, testing, commisioning of lighting fixtures complete with mounting bracket, flameproof, control gear box as per the type of fixtures, lamps, etc incliuding pipe inserts for cables and conncting works, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge.Flameproof cable glands to be used in flameproof fitting.Work should be completed in all respects.
Area lighting, integral flameproof well glass fixtures (CMIFR approved for Zone1 and 2, Gas group IIA and IIB, Temp.Class T3) with 100 W LED luminiare with flameproof control gear of Baliga make or equivalent)
Street Light pole 7 metre high GI octagonal pole complete with bracket, GI clamps for fixing flameproof light fitting. 4 way flameproof pole JB, cable from JB to fixture, flameproof gland, civil works and its materials including all labours and complete materials .
INDOOR LIGHTING AND WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Scope includes supply of all components (MS/PVC conduit, JB, wire, etc) and labour
Wiring for power plug point (16A) upto 10 M with 4.0 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with (including) modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS Scope includes supply of all components MS/PVC conduit, PVC insulated copper conductor single core wire, GI box, modular plate, 20A modular switch, 16A modular plug, wire etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell / 5A plug point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, ceiling rose, suitable Gl box and earthing the point with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. All material and labour are included in the scope of the contractor.
Supply and fixingof recess/ Surface/ Pendent mountinground 12 to 15 Watt LED Light having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respect.Make and Model Havells Or Equivalent
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 36/40 watt LED tube light complete includingtube etc on surface complete in all respect.
Supply, Installation, testing and commissioning of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, complete with all accessories similar to Havells model Pacer/Havells/Usha /Orient )
Supply and Installation of latest model (5 stars BEE certified) 2 T split inverter AC complete with remote, 5 KVA stablizer, MS Stand for outdoor unit etc. complete in all respect.
Supply, Installation, Testing and commissioning of flameproof (CMIFR approved ) 12'' Exhaust fan, 0.25hP motor, 1440 rpm .Wiring to be done using 3 core FRLS cable .Switch to be placed outside the battery room.
Supply, Installation, testing and commisioning of flameproof LED 1x36/40W tubelights for battery room .Wiring to be done using 3 core FRLS cable .Switch to be placed outside the battery room.
CABLE TRAYS
Supply, Installation, Erection of following Hot Dip Galvanized Lader /perforated type cable trays (as per IS 2629) including bends, tee, crosses, horizontal, insert plate, tray supports and verticle splices etc as required including supply of all GI hardwares, civil works and its materials, all labour and material as required as per standard drawings, specifications and direction of Engineer-in-charge.
150 mm wide
300 mm wide
Installations of cable route markers along the cable route at an interval of 20 metre as well as cable bends and joints.
HDPE CABLE CONDUIT
Supply and laying of following sizes of HDPE cable conduit in required length fixed on steel, concrete or similar structure, laid in trenches, digging, construct conduit ductbank and buried in concrete including cutting, bending, and similar works, supply of clamps, small iron structures, spacers and installlation iof seats, plugs and bushings etc.Civil works and its materials, incluiding all laboures and materials complete as for approved drawings and directions of Engineer-in-Charge.
GG SET with AMF PANEL
Supply installation, testing and commissioning of natural Gas engine generator with AMF panel as per following requirements and as per VCS standard specification VCS-SS-EL-4004 and Datasheet VCS-DS-EL-4004. Gas engine generator shall meet latest CPCB IV+ norms. The Gas Engine shall be suitable for generating set application developing minimum 83 HP at 1500 RPM under NTP conditions of BS: 5514 or equivalent in IS, turbocharged, water cooled, with radiator, Engine to be sufficient for alternator of 58.5 KVA at 0.8 pf (lagging) i.e., 46.8 KW. Starting System : 12 V battery operated electric motor starting. Starting system shall be capable of three successive starts. Battery type: sealed SMF. The engine shall be supplied complete with coupling, guard, as well as outlet exhaust pipe with silencer. Alternator with rated output of 58.5 kVA at STP suitable for continuous operation at 1500 RPM developing 415 volts at 0.8 p. f. (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless type, drip proof, screen protected as per IP-23, self excited & self regulated. The alternator will be suitable for tropical climate and shall conform to IS:4722. AMF panel (automatic mains failure panel) control suitable for 58.5 KVA Gas Engine genrator complete with relays, timers, set of CTs for metering to indicate currents,phase and line voltages, frequency, power factor, KWH etc.
SAFETY MATERIALS
Supply and installations of the following iuncluding the supply of necessary clamps, boults, roll plugs etc.Breaking and making good of walls, If required, and all including all laboures and materials complete as per directionsd of engineer in charge, applicable standards and Indiuan electricity rules.
CO2 fire extinguishers(4.5kg)
4 sand Buckets with stand .
Caution Boards[Danger, High violtage] including supply of necessary clamps, bolts and other hardwares.Supply and installations of vitreous enamels, caution boards suitable for 440 volts as per each IS:2551 including fixing on the walls with all the required hardware etc.Complete in english and hindi or local language.Size 200mmx250mm.
Shock hazards charts complete with frame and glass .Size A3 and glass thickness 2mm.
Singe Line Diagrams complete in glass frame .Size A2 and glass thickness 2mm.
TOOL KIT
Rubber hand gloves suitable for 440 volts
First Aid kit
Philips head screw driver of each size 3mm, 3.5mm, 5mm
Flat head screw driver of each size 3.5mm, 5.5mm, 6.5mm
Line Tester suitable for 3 phase, 440 volts
Open head Spanner set of size(6mm-17mm)
INSULATING MATS
Supply and laying of insulating Mats 11kV grade (as per IS:15652-2006) of 1000 mm width.
DISTRIBUTION TRANSFORMER
Supply, Installation, Inspection, Transportation to site, erection on pole, testing and commissioning of 11kV/433V outdoor type, 3 phase, 50Hz, copper wound, ONAN distribution transformer complete with all accessories as per IS2026/1180 and latest ammendments and there of and first oil filled.Termination arrangements for HV side: HT bushing &LV side cable end box /terminal box of following ratings.
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating; pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection between the OH Line & HT bushing of transformer, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.
Supply, erection and commissioning of 11 kV, ACSR weasel conductor as required for stringing between State Electricity Board Double pole and consumer double pole structures including supply and erection of pole, crossarm, pin insulator etc.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x2.5 mtr.) complete with all material, welding and labour
40 mm blue granite metal for spreading in the fenced area .
EMERGENCY SHUTDOWN BUTTON
Supply &Installation of emergency shutdown butons with latching lift flap, flameproof type (Zone 1&2 and Gas group IIA & IIB) and weatherproof enclosure IP65, quick release provision, NO NC contacts to trip all the incomers simultaneously of the main electrical distribution board and UPS distribution boards incomer.Location of installation to be decided during detailed emngineering.
SECTION-D : INSTRUMENTATION WORK
Supply, Calibration and Installation of instrumentation items listed below: (For details, refer instrumentation specifications)
Supply, Installation, Testing & Commissioning of Pressure Gauge as per Datasheet, Specifications and P&ID Supply, Installation, Testing & Commissioning of SS-316 Pressure Gauge of 150mm(6 inch) Dial Size , C-Type Bourdon Tube, Solid Front Type with 2 Way Manifold, direct mount,Range: 0-60 Kg/cm2, as per the Datasheet attached with the Tender Document.
Fire Alarm System Supply, configuration, testing, installation, erection and commissioning of Addressable Type Fire Alarm System including Fire Alarm Control Panel, Detectors, MCP, hooter, panel and cables. FACP shall be installed inside control building of CGS as per Technical Specification of the tender.
Fire Alarm Control Panel (FACP) Supply, Installation, Testing & Commissioning of Analogue Addressable Fire Alarm Control Panel , installed in CGS Control Room complete with battery backup and accessories, interfaces with RTU and inclusive of cabling, termination etc.
Supply, Installation, Testing & Commissioning of Smoke Detectors ((Addressable type) with Response Indicator Combination of (Ionization+Photoelectric) complete with wiring and accessories for installation inside the Control Room/Electrical Room/Guard Room as per Tender datasheet.
Supply, Installation, Testing & Commissioning of Heat Detector with Response Indicator (Addressable type, IP - 42 Protection Class), complete with wiring and accessories for installation inside the Control Room/Electric Room/Battery Room as per Tender datasheet.
Supply, Installation, Testing & Commissioning of Manual Call Point (Indoor Application) complete with wiring and accessories as per Tender datasheet.
Supply, Installation, Testing & Commissioning of Conventional Sounder / CUM Strobe, Power Supply 24VDC, 3 Tone, Xeon Flash Tube, Enclosure Material- FR ABS Plastic Red complete with wiring and accessories.
CCTV System Supply, Installation, Testing & Commissioning of CCTV System including CCTV Cameras, PoE Ethernet Switches, CCTV Workstation, Network Video Recorder (NVR) and Server Rack, CCTV Mounting Stantion/Pole.
Supply, Installation, Testing & Commissioning of IP PTZ camera (for process area) day Night HD 4.0 MP,explosion proof with required connecting patch cords, wall/pole mount installation accessories as per technical specification. PTZ camera shall be powered by PoE switch via Cat6 cable
Supply, Installation, Testing & Commissioning of IP Dome Type (Inside the Control Building) camera HD 4.0 MP, IP42 with required connecting patch cords, wall/Celling mount installation accessories as per technical specification. Dome camera shall be powered by PoE switch via Cat6 cable.
Supply, Installation, Testing & Commissioning of IP Fixed camera (For entry & Emergency gate) day Night HD 4.0 MP, explosion proof with required connecting patch cords, wall/pole mount installation accessories as per technical specification and shall be powered by PoE switch via Cat6 cable.
Supply, Installation, Testing & Commissioning of PoE Ethernet Switch 8 port with connecting patch cords, Pigtails and other required accessories as per technical specification.
Supply, Installation, Testing & Commissioning of LCD Display unit (24"), Keyboard with Joystick along with required cables, connectors, interfaces complete as per technical specification.
Supply, Installation, Testing & Commissioning of 8 Port Compact Network Video Recorder (NVR) with (4TB) of 30 days recording, connecting patch cords, Pigtails and other required accessories cameras as per technical specification.
Supply, Installation, Testing & Commissioning of Wall Mounted Rack: 600mmwidth/800mm Depth for installation of NVR unit and other related equipments as per technical specification.
Supply and Installation of CCTV Mounting Stantion/Pole, mounting fittings and accessories etc. as required
Cables, Cables Trays and Junction boxes Supply, laying in tray/tenches, testing, erection of armoured signals cable from field instruments to junction boxes including termination, glanding, ferruling, dressing etc at both ends. Supply of cable trays, cables glands, junction boxes, erection materials, cable ferrules, cable lugs, cable ties. Supply, Installation and erection of cable trays and junction boxes.
2C X 1.5 Sq.mm, Fire Resistant, Overall Screened/Black
CAT-6 CCTV CABLE
RS 485/ SERIAL LINK /MODBUS CABLE
Notes: 1. Quantity includes minimum contingency and wastage
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.19 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
CommercialVolume.pdf
Tender Documents • 2.19 MB
BOQ_79092.xls
BOQ • 0.68 MB
TechnicalVolume1.pdf
Additional Documents • 3.98 MB
TechnicalVolume2.pdf
Additional Documents • 9.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .