| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.5 L+₹6,714.51 (0.33%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹23.6 L+₹3.2 L (15.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹24.1 L
EMD Value
₹48,200
Closing Date
4 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gurdaspur
Garrison Engineer Gurdaspur (Tibri)
Provision of certain E/M Minor works at Tibri Mil Stn under GE Gurdaspur
2023_MES_627234_1
GE GSR-60/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹48,200
3 Jan 2024
7 Nov 2023
11 Dec 2023
7 Nov 2023
4 Dec 2023
22 Nov 2023
Amount
Point wiring with PVC insulated and PVC sheathed single core multistranded FRLS copper conductor cable of size 2.5 Sqmm (nominal area) using approved colour coding, 1100 volts grade, ISI marked, including PVC conduit heavy grade, 20 mm or higher dia. with fittings concealed in wall with continuous earth wire of PVC insulated and PVC sheathed single core multistranded FRLS copper conductor cable of size 2.5 Sqmm (nominal area) 1100 volts grade, ISI marked and connecting to the common earth dolly including provn of 3mm thick plastic laminated sheet of appropriate size and sunken CI/pressed steel terminal boxes for mounting switches, sockets etc. including cutting chases and making good to the disturbed surfaces as per existing for 16amps 3 pin socket outlet controlled by one, one way switch complete all as specified and directed.
S&F swich piano flush type single pole 1 way 15 Amp complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin 15 amps flush type complete all as specified and directed.
Supply and fixing GI pipe 15mm dia medium grade with all fittings and fixed complete to wall and ceiling including drilling hole on wall for incoming and outgoing pipe complete all as specified and directed.
Supply and fixing GI pipe 20mm dia medium grade with all fittings and fixed complete to wall and ceiling including drilling hole on wall for incoming and outgoing pipe complete all as specified and directed.
Supply and fixing gun-metal, globe or gate valves with iron wheel head, screwed both ends ISI marked suitable for 20mm dia iron pipe complete all as specified and directed.
Supply and fixing gun-metal, globe or gate valves with iron wheel head, screwed both ends ISI marked suitable for 25mm dia iron pipe complete all as specified and directed.
Supply and fixing gun-metal, globe or gate valves with iron wheel head, screwed both ends ISI marked suitable for 50mm dia iron pipe complete all as specified and directed.
S&F bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe 15mm bore complete all as specified and directed.
Supply & fixing for storage water heater (Geyser) of 25 ltr capaicty 230V AC, 50 Hz having element of 2 KW of copper/ Incoloy alloy, rust proof outer body, high density PUF insulation, BEE 5 star rated, inner tank of stainless steel 304 grade which can sustain pressure of minimum 8 Bar working pressure and having multifunction safety valve making electric and water connection complete all as specified and directed.
S&F and grouting 4 Nos nut & bolts 200mm long 12mm dia in wall for fixing one geyser complete all as specified and directed.
Supply and fixing PVC connection 15mm dia PTMT nut of length 450mm complete all as specified and directed.
Supply and fixing stop valve cast copper alloy 15mm dia screwed down high pressure with crutch or butter fly handle screwed both end for iron pipe complete all as specified and directed.
Supply and fixing stop valve cast copper alloy 20mm dia screwed down high pressure with crutch or butter fly handle screwed both end for iron pipe complete all as specified and directed.
Supply, assemble, installation and commissioning water purifier RO + UV wall mounted and purifier 60 litres/ hours electric type of ABS food grade plastic including all necessary connection all as specified and directed.
Supply and fix for 1000 litres capacity, rotational moulded polythelene water storage tanks white (ISI marked) (three layer, cylindrical vertical with closed top), hoisted and fixed in postion including 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) complete all as specified and as directed.
S&F of GI tubing, medium grade, galvanised with all fittings laid in trenches of size 50mm bore complete all as specified and directed.
S&F of GI tubing, medium grade, galvanised with all fittings laid in trenches of size 25mm bore complete all as specified and directed.
S&F of GI tubing, medium grade, galvanised with all fittings laid in trenches of size 20mm bore complete all as specified and directed.
Construction of brick masonary valve pits of internal dimensions 600mm x600mm x 600mm. Brick work shall be in CM 1:4. PCC floor of the pit shall be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space, floor of the pit shall be 15 cm thick in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, finished even and smooth without using extra cement, internal surfaces of the pit shall be plastered in CM (1:4) 15 mm thick. The sluice valve and other fittings shall be housed in centre of the pit. The top cover of the pit will be made out of MS sheet min 2mm thick with angle iron frame made out of MS angle 50mm x50 mmx 6 mm with galvanised steel hindges two Nos and locking arrangements, duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed.
Cutting existing steel tubing for alterations or additions, screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) for iron pipe 40 or 50mm bore (Each cut measured) complete all as specified and directed.
Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m deep and getting out complete all as specified and directed.
Returning, filling in soils including spreading, leveling and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material n.exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting pointcomplete all as specified and directed.
Supply, install, testing and commissioning of diesel engine driven Generating set with acoustic enclsoure (Silent Version) conforming to latest CPCB Norms of 15 KVA or next higher capacity, radiator water cooled, Diesel engine driven developing suitable BHP at 1500 RPM coupled with alternator of capacity 15 KVA delivering out put Voltage 415 Volts +/- 1.0% at set value of 415 V at a frequency 50HZ +/- 0.5% with suitable AVR control panel, all mounted in acoustic enclosure all as per manufacturer's design and specification as per CPCB norms confirming to the detailed specifications appended below including all equipments and accessories as follows :- (i) ENGINE :- (a) General: Suitable for four stroke compressed ignition, radiator water cooled, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature. The prime mover provided should be as per IS specifications. (b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.
(c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire load of the exhaust system shall not fall on the DG Set. A sufficient length of straight pipe shall be provided after the exhaust silencer to leave the gases at sufficient height above the engine and outside the room. (d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, The fuel tank must have proper locking arrangement. (e) Cooling System: Should comprise of radiator with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts.
(g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable size and maintenance free battery with in built battery charger to be mounted in trays (having rubber insulation) on the main frame made out of angle iron of 40x40x5mm with in-built charging unit. It should have the provision to charge the battery from external sources during static condition and while running of the generator. (ii) ALTERNATOR: AC alterator shall be horizontal and foot mounted, 15 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details. (a) Type, Brush less AC Generators (b) Output rating 15 KVA (c) Output Voltage: 415 ± 1.0% under all loading conditions. (d) Output frequency 50Hz ±0.5% up to 0.8 lagging. (e) No of Phases: 3 phase with 01 Neutral (4 wire) (f) Mounting : Horizontal foot mounted. (g) Enclosure : Minimum IP-23 ICO/ Drip proof and screen protected. (h) Digital automatic voltage regulator. (j) Class of insulation-'H' (k) Ambient operating temperature : up to 50° C
(iii) Install on the foundation, connecting fuel lines, cable etc. (iv) Testing and commissioning complete (v) The cost of cables/control cables from engine (LT) to control panel shall be deemed to be included in the cost quoted. (vi) BASE FRAME: Shall be fabricated with MS channel frame which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads. (vii) ACCESSORIES: (a) 01 No standard mechanical and electrical tool box. (b) Internal covered tube lights. (viii) Acoustic Enclosure: The entire generator, prime mover, fuel tank and control panel should be housed in a sound proof acoustic enclosure. Noise level should not exceed 75dBA at 1m as per latest CPCB norms. Proper ventilation should be provided and accessibility for easy maintenance. (a) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination (b) Doors: The container will be provided with suitable doors on the side and rear to enter the container during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door
(ix) Painting Scheme ISS shade 220 olive green 1994 or As per manufacturers specification Container with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation. (x) Lifting/Transportation arrangements (xi) Trials:- Trials on site should be given as per load tests prescribed and all functional trials should be shown. (xii) Providing suitable cement concrete foundation PCC 1:2:4 type B1 using 20mm grade stone aggregate as per manufacturer's design as approved by GE including excavation and earth work complete. Notes : (a) The Engine, alternator,control Panel, Acoustic enclosure shall be integrated unit sourced from OEM only as per Make given above. (b) All arrangements for Installing, testing & commissioning of DG set is deemed to be included in the quoted rate. The rate quoted deemed to be inclusive of first fill of Engine oil/Lub oil & POL for testing & commissioning complete. (c) Contractor will submit the technical litrature of specific model for approval before placing order. (d) Maintenance chart and manufacturer instruction sall display on wooden board including catalogue board.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. Note: Excavation and earth work, sand cushioning, brick protection, GI pipe shall be measured and paid separately.
S&F of MCCB 63 Amps 4 Pole 25KA with fixed magnetic and adjustable thermal setting complete all as specified and directed by Engineer-in-Charge.
S&F on load change over switches 63 Amp, TPN, 415 volts with sheet steel enclosure with side handle complete all as specified and directed.
Supply and lay brick common burnt sub class "B" old size for protection of cable laid in trenches for under ground cable all as specified.
M&L sand cushioning in trenches using fine sand to under ground cable, laid in two layers before laying the cable & after laying the cable complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common saft filling in alternate layers and electrode connection by using earth lead of galvanised iron strip size 32mm x 6mm by means of bolts, nuts, check nuts and washers made of galvanised iron or steel and thimbles, connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh, including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar including necessary excavation and earth work in any type of soil, returning filling approved soil and disposed of surplus soil to a distance not exceeding 50m away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).
kailu construction co
P S BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .