Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹11.8 L+₹1.3 L (12.1%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹12.8 L+₹2.3 L (21.4%)Rejected-Finance 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹13.7 L+₹3.1 L (29.4%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹15.7 L+₹5.1 L (48.4%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF EM NATURE OF WORKS IN SALARIA OFFICERS ENCLAVE UNDER GE WEST DELHI CANTT 10
2022_MES_520771_1
GE/DW-50/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹60,000
5 Sept 2022
21 Jul 2022
18 Aug 2022
22 Jul 2022
16 Aug 2022
4 Aug 2022
Amount
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 3. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contracror shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at Piru Vihar for collection of complaints from the concerned JE in charge. 7 Job slip as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,ceiling light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacity shall be issued by the department free for fixing and labour shall be paid unde respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site shall be deposited to MES store Yard.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power/call bell) complete and making good the disturbed surfaces of wall/floors/ceiling etc) and all fitting fixtures deposited to MES store Yard complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly in existing pressed steel sheet Metal sunken box to be fixed switches/sockets etc with modular cover plate/3mm thick plastic laminated sheet for the foiiowing complete all as specified and directed. :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 4 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed.
All as per item No.4 here in before but with 2x4 Sqmm and 1x 4 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed.
S & F of Modular socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
S & F of switch Modular type 5/6 amps single pole one way complete all as specified and directed.
S & F of Modular switch 15 amps single pole one way complete all as specified and directed.
S & F of Modular Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S & F of Modular ceiling fan regulator step type 2 module for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
S & F Modular Bell push single pole one way complete all as specified and directed.
S & F Bell ding dong complete all as specified and directed.
M&L ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed.
M&L in repair for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit in walls 02 runs of IC x 10.00 sqmm (Main Cable and neutral) and one run of IC x 10.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection making good surface of distubed area complete all as specified and directed.
S&F in Replacement of inner shell Copper body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F in Replacement of inner shell Stainless steel body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F in Replacement of Copper Heating Element 1500 watt suitable for Geyser of 25 Ltr capacity complete all as specified and directed.
S&F in Replacement of thermostat suitable to work at water temperature 30° to 75° C electric cut up for any type of water heater complete all as specified and directed.
S&F in Replacement of copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
M&L Replacement of MS outer shell suitable for geyser of capacity 25 ltr complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduiT with 3x1.5 Sq mm (Nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly including taking down of old wires complete all as specified and directed. :
Supply, laying and drawing submain wiring in existing concealed PVC rigid condui with 3x2.5 Sq mm (Nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly including taking down of old wires complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit on walls 02 runs of IC x 4.00 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store and refixng the same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed.
M&L for rewinding exhaust fan of 300mm/450mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
M&L in repair lower shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 6 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
M&L for scarapping/cleaning to rusted/pealing area on surface of ceiling fans including sweeps,down rod,fan Hook after cleaning applied two coats of spray painting complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, ladder and safety measures to make it functional complete all as specified and directed.
Supply and fixing in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
(i) SP 5 To 32 AMP
(iii) SPN 40 to 63 AMP
Supply and fix in repair exhaust fan motor up to 300 mm as per sample complete all as specified and directed.
M & L in repair earthing complete with copper earth plate 600x600x3.15mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to 20x3mm copper strip by means of bolts, nuts, check nuts and washers of copper strip and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 40mm bore for copper strip, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) with MS handle and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing on completion all as directed .
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire as earthing lead complete all as directed including taking down the old unserviceable complete all as specified and directed.
S&F in repair metal plug top 16 Amps 3 pin 230- volts complete all as specified.
S&F in repair metal plug socket 16 Amps 3 pin 230- volts complete all as specified.
S&F in repair top cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site complete all as specified and directed.
S&F in repair bottom cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site complete all as specified and directed.
S & F in repair hole fastner madeup of MS 6" long with complete nut bolt complete all as specified and directed.
S & F in repair hole fastner madeup of MS 4" long with complete nut bolt complete all as specified and directed.
S&F exhaust fan blade of any make for size 225 mm to 300 mm sweep as per requirement at site complete all as specified and directed.(As per sample)
S&F ceiling fan blade 1200 mm sweep made up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed.
S&F in repair SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed.
M&L in repair switch Modular type 6 Amps one way 230V AC as per sample complete all as specified.
M&L in repair switch Modular type 16 Amps one way 230V AC as per sample complete all as specified.
M&L in repair Modular socket outlet 5 pin 6 Amp socket 2 module as per sample complete all as specified.
M&L in repair switch bell push Modular type 6 Amps 1W-1 module, 230V AC as per sample complete all as specified.
M&L in repair Modular socket outlet 5 pin 16 Amp socket 2 module as per sample complete all as specified.
M&L in repair Modular fan regulator 2 module as per sample complete all as specified.
Supply & Fix in repair PVC round plate suitable for covers of junction boxes and joints of circuits with suitable screws complete all as specified and directed.
Supply and Fix in repair decorative, wall mounting, champagne gold finish fixtures with plastic body with acrylic cover suitable for 9 Watt led lamp B22 base complete all as specified & directed.
S & F in repair Bell ding dong complete all as specified and directed.
Supply & Fix in repair LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed.
Supply and fix in repair Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repair Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repair 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 161746.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
GAUTAM ELECTRIC WORKS
jain associates
M/s Birja Nand
M/s Adhikari construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .