Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹11.5 L+₹2.6 L (28.9%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹13.6 L+₹4.7 L (52.3%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹31,500
Closing Date
14 Oct 2020, 6:00 pmClosed
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2020_MES_379397_1
GE(S)/PAT-36/N/2020-21
Open Tender
Civil Works
Item Rate
150 days
Mil Stn Nabha
Refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (South) Patiala
₹31,500
Yes
31 Oct 2020
21 Sept 2020
16 Oct 2020
21 Sept 2020
14 Oct 2020
29 Sept 2020
21 Sept 2020 - 28 Sept 2020
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc complete all as specified and directed.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point includig cutting chasing and making good with CM 1:3 where required, complete all as specified and directed. in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular type, socket 5 pin 6 Amps, 2 modue complete all as specified.
Supply & Fix modular socket 5 pin 6/16 Amps, combination type 2 moduel complete all as specified.
M&L for Modular switch 1 way 6A, 1 module type all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type all as specified and directed.
Material and labour for Modular Bell push 6A 1 module complete all as specified and directed.
M & L for Fan step regulator, 120W, 2 module all as specified and directed.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing for sub main wiring two single core FRLSH PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit of size not less than 25 mm in dia with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring, and making good the disturbed suface, complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) If necessary cutting / chasing and making good disturbed surfaces of wall, floors etc shall be deemed included in quoted rate.
Supply and fixing for sub main wiring two single core FRLSH PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit of size not less than 25 mm in dia with 2.5 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring, and making good the disturbed suface, complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) If necessary cutting / chasing and making good disturbed surfaces of wall, floors etc shall be deemed included in quoted rate.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 4 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job, complete all as specified and directed.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job, complete all as specified and directed.
Supply & fix in replacement of existing unserviceable Vertical three phase MCB distribution board powder coated double door flush mounted complete with locking arrangement suitable for 4 way VTPN, with MCCB of capacity 100 Amp FP as incomers and MCB's as out going with rated bus bar 200 Amp link 230 volt : i) Connnections of the MCCB's / MCB'S with cable shall be made through appropriate size of pin / bottle type copper thimble (properly crimpled). ii) The DB shall be flushed, fixed and the disturbed surface shall be made good as per exting surface and it is deemed included in quoted rate.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core, including taking out unserviceable cable complete all as specified and directed.
S&F in replacement of existing unserviceable COB Led Flood light slim and light weight energy saving LED flood light single piece PDC aluminium body with glass visor fitted in frame, equipped with secondary optical lense for superior light distribution of capcity 70 watt 6000k including necessary electric connection, complete all as specified and directed.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply & fix in replacement of existing unserviceable FTL with new techonlgy ultra bright led tubelight with polycarbonate diffuser having high efficacy suited for installation in existing t5 tubelight with G5 lamp holders to give glare free light of capacity 18W 865 1148mm LED including neccessary electric conection with batten complete all as specified and directed.
Supply & fix in replacement of existing unserviceable batten with BOX TYPE Pre-coated CRCA body, heavy duty regaL Batten for LED tube universal batten for G13 T8 lamps including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface.
S&F in replacement of existing unserviceable surface mounted LED down light in engineering plasting housing with clear prismatic diffuser with LED lamp 9 watt white light, complete all as specified and directed.
Material and labour for in replacement angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 23 watts for batten fitting, including plastic square board of required size, complete all as specified and directed.
Supply and fix in replacement LED Lamp LED new Adore 7W E27 WW Ball Lamp LHLDERHEMD 8X007 7 watt all as per specified and directed.
Material and labour for call bell ding dong AC 230 volt single pole complete all as specified and directed.
S&F in replacement of existing unserviceable LED building light IP 66 powder coated pressure die cast aluminium compact high power LED fitting 25 watts with heat resistant toughned glass complete with all accessoreis watts complete including GI pipe bracket made out 40 mm dia GI pipe medium grade of 1.20 mtr long and make to shape fixing with 40x6mm size of flat iron clamp, nuts , bolts and washers connection including two coat of aluminium paint over a coat of primer and fixing the fitting on bracket and all the electrical connection, complete all as specified and directed.
M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I , complete all as specified and directed.
Supply and fix in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit led luminaire comprising of high brightness LED of capacity 10 Watt complete all as specified and directed.
NARINDER KUMAR SONS
B D BATRA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .