Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.4 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹11.2 L+₹1.8 L (18.7%)Rejected-Finance A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 2 | Rejected-Finance Not being lowest |
Tender Value
₹10.4 L
EMD Value
₹20,820
Closing Date
11 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112, Taj Road Agra Cantt
PROVN OF WPN TRG AID STORE AT AGE (I) FATEHGARH
2022_MES_501499_2
86103/E8
Open Tender
Civil Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted in Class E category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹20,820
Yes
31 Mar 2022
18 Feb 2022
17 Mar 2022
18 Feb 2022
11 Mar 2022
25 Feb 2022
18 Feb 2022 - 21 Feb 2022
60 days
Amount
Excavating in trenches not exceeding 1.50M wide and not exceeding 1.50M depth for foundation etc or for shafts, wells, cess pits, manhole exc not exceeding 10 Sqm on plan and not exceeding 1.50M in depth and getting out in soft loose soil complete all as specified and directed at site.
Returning filling in including spreading leveling watering and well ramming in layers n exc. 25 CM complete all as specified and directed at site
M&L Filling under floors including spreading and leveling in layers n. exc. 25 Cm including well ramming and watering as required complete all as specified and directed at site.
Removing excavated materials n exc. 50M and depositing where directed at a level n. exc. 1.50M above the starting point complete all as specified and directed at site.
M & L for cement concrete in foundation filling and mass concrete 1:4:8 type D-2 using 40 m graded stone aggt complete all as specified and directed at site
M&L for 75mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggt as in sub base to flooring complete all as specified and directed at site
M&L PCC 1:2:4 type B0, 12.5 mm graded aggregate as in cills, steps, and other similar bands, plinth courses etc. complete all as specified and directed at site
M&L Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed at site
M&L Broken stone hard core of gauze not exceeding 63 mm and depositing where directed at level not exceeding 15 cm in layers , watered and rammed to a true surface, complete all as specified and as directed
M&L for RCC M-25 Design mix as in foundations, including rafts, footings, foundation, beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed at site.
M&L for RCC M-25 Design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, shelves complete all as specified and directed at site
M&L for RCC M-25 Design mix as in chajja/sunshades/shelf’s etc. complete all as specified and directed at site
M&L for RCC M-25 Design mix as in beams, cantilevers, bressummers, and lintels over 1.5 m span complete all as specified and directed at site
M&L for RCC M-25 Design mix as in columns, pillars, piers, posts and struts complete all as specified and directed at site
M&L TMT bars 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping ends and binding with mild steel wire not less than 0.9 mm dia, complete all as specified and directed at site
Ditto as per item No 15 above, but 6 to 8 mm dia bars complete all as specified and directed at site
All as per item No 15 above but 6 to 10 mm dia as in stirrups/spacers etc complete all as specified and directed at site
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6 m mean radius, built in CM 1:6.complete all as specified and directed.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed at site
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed at site
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders complete all as specified and directed at site.
Use & waste of for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, balconies, canopies, shelves n. exceeding 200mm thick complete all as specified and directed at site
Use & waste of formwork to edges of concrete flats, breaks in floor, openings in conc. Walls, floors and roofs and sides of RCC/PCC bands in walls horizontal or sloping and similar work not exceeding 20cm wide complete all as specified and directed at site.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors window cills, floor and roofs work exc. 5cm but n exc. 10 cm wide complete all as specified and directed at site.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed at site
Material and labour for 5 mm thick rendering in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed at site
M&L for rendering 15mm thick plaster in CM 1:4 on fair faces of brick work complete all as specified and directed at site
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 surfaces finished even and fair faces complete all as specified and directed at site.
M&L MS work as in Framed work as in chowkhats of doors or gates of angle or other section with gusset plates, rails, braces, etc., complete all as specified and directed at site
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed at site
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed at site
S&F factory made 35 mm th Plain framed, paneled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed at site
S & F mild steel sliding door bolt 300mm long clip type, stove enameled black with bright bolt not less than 16mm dia complete all as specified and directed at site.
S & F mild steel barrel tower bolt 200mm long, stove enameled black with bright bolts. complete all as specified and directed at site
S & F mild steel pressed handle oval type stove enameled black of size 150mm complete all as specified and directed at site.
S & F mild steel butt hinges cold rolled of size 100mm medium weight complete all as specified and directed at site.
M&L for Preparing of new plastered surfaces & applying 3 coats of white wash as in ceilings complete all as specified and directed at site
M&L for Preparing of new plastered surfaces of wall & applying 2 coats of OBD distemper over a coat of white cement primer as in walls complete all as specified and directed at site
M&L for Preparing of new plastered surfaces & applying 2 coats of cement base paint over a coat of white cement primer complete all as specified and directed at site.
M&L Preparing surfaces new of steel and applying two coats of SE paint complete all as specified and as directed.
All as per item No 40 above , but with over a coat of red oxide primer complete all as specified and directed at site
M&L preparing surfaces new of wood and applying two coats of SE paint over a coat of pink primer complete all as specified.
M & L 40 mm thick cement concrete with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring finishing surfaces even and smooth w/o using extra cement complete all as specified and directed at site
S&F 3mm thick, 38 mm wide glass dividing strips complete all as specified and directed at site
M & L for Surface dressing not exceeding 15cm deep in any type of soil complete all as specified and directed.
M & L for Chequered cement concrete tiles 20cm x 20mm thick , set, jointed in near cement slurry in floors over 20mm screed bed in CM 1:4 etc complete all as specified and directed.
Surface excavation n.exc (not exceeding)30 cm deep and getting out etc complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20mm stone aggt as in kerb complete all as specified and directed..
M&L Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5Sqm in each pane complete
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multi stranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour. (a) One 5 pin 5 Amp light/holder/fan/exhaust fan point controlled by one switch complete all as specified and directed at site
(b) One 5 pin 5 Amp switch socket combination point on an independent board complete all as specified and directed at site.
(c) One 5 pin 5 Amp socket point controlled by one switch on same board complete all as specified and directed at site.
All as per item 50 here in before but for one 15 Amp 6 Pin switch socket combination independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed at site.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed at site
S&F switch socket combination 5 in 1, 16 Amp flush type complete all as specified and directed at site
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 Sqmm FRLS and one run of 6 Sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.(Make : Legrand cat part No 5076 11)
S&F of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specified and directed.
S& MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed at site
S&F building security LED light 14 watt with IP-65 including suitable size of GI bracket complete all as specified and directed. (Make: Philips Cat No BRP 042 LED 14 CW MR S1 PSU GR or equivalent in Havells/Bajaj)
M&L for sand cushioning to U/G cable in layers of 23 cm thick (8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Punned down volume shall be measured.
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Supply and laying in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified and as directed.
M&L Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S&F of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified.
M/S WASEEM KHAN CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .