Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹33.9 L+₹34,326 (1.02%)Rejected-Finance DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹46.1 L+₹12.6 L (37.4%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | Rejected-Technical SHOP NO 48 HOSANNA LAXMI VENKETESWARA LAYOUT 2ND CROSS MARAGONDANAHALLI K R PURAM POST BANGALORE 560036 | BENGALURU URBAN | KARNATAKA | 560036 | - | Rejected-Technical Not enlishted in a(ii) categories |
Tender Value
Refer Docs
EMD Value
₹85,500
Closing Date
26 Dec 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF WATER SUPPLY DISTRIBUTION SYSTEM ATTENDING DAY TO DAY WATER OVERFLOW LEAKAGE RELATED COMPLAINTS OTHER MISC WATER SUPPLY WORKS AT AFS JALAHALLI
2023_MES_629882_1
8854/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹85,500
18 Jan 2024
28 Nov 2023
28 Dec 2023
28 Nov 2023
26 Dec 2023
12 Dec 2023
28 Nov 2023 - 5 Dec 2023
Amount
Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed.
Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete made out of Precast cement concrete of Type C1 1:3:6 (20 mm graded aggregate) (with plain or interlocking joints as directed) setting in cement mortor 1 : 4 , complete, in walls all as specified and directed by Engr-in-charge.
Material and labour for Rendering 10 mm thick on fair faces of brick work or concrete surface cement paster with the ratio of 1:6 finished even and smooth (without using extra cement).
Material and labour for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges , in lintels upto 1.5m clear span, and other similar bands, railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
Dismantling structural steel work in cluding doors, gates but excluding framed truss etc.
Supply and fixing Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel for fabrication of valve pit chamber, raising main support and motor foundation supports etc.
Material and labour for Fabricate supply and fix valve chamber covers made out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted cover all as directed by Engineer-in-Charge.
Material and labour for Cement concrete in foundations, filling and mass concrete PCC 1:2:4 foundation B-2 type for repair of valve pit chamber.
Material and labour for Painting with two coats of synthetic enamel paint over coat of zink chrome on surfaces of any description, over 10cm in width or girth,not otherwise described
Repairs to sluice valve of size 80 mm dia CI by taking out defective spindles and check nuts of any type and replacing the spindle with new as per site but check nut of any type with new brass check nut complete all as specified and directed.
Repairs to sluice valve of size 100 mm dia CI by taking out defective spindles and check nuts of any type and replacing the spindle with new as per site but check nut of any type with new brass check nut complete all as specified and directed.
Repairs to sluice valve of size 150 mm dia CI by taking out defective spindles and check nuts of any type and replacing the spindle with new as per site but check nut of any type with new brass check nut complete all as specified and directed.
Removing the gate from sluice valve of size 80 mm dia in position and metalizing with bronze and match with standard size and refixing in position complete all as specified and directed.
Removing the gate from sluice valve of size 100 mm dia in position and metalizing with bronze and match with standard size and refixing in position complete all as specified and directed.
Removing the gate from sluice valve of size 150 mm dia in position and metalizing with bronze and match with standard size and refixing in position complete all as specified and directed.
Material and labour for replacing the gland packing of sluice valves of size 80 mm dia complete all as specified and directed.
Material and labour for replacing the gland packing of sluice valves of size 100 mm dia complete all as specified and directed.
Material and labour for replacing the gland packing of sluice valves of size 150 mm dia complete all as specified and directed.
Refixing of old serviceable GI tubing on wall/ceiling/under floor and in trenches of size 80 mm bore and connection in new or old positions including taking down, cleaning, cutting, threding along with GI fittings where ever replaced and required at site complete all as specified directed.
Refixing of old serviceable GI tubing on wall/ceiling/under floor and in trenches of size 50 mm bore and connection in new or old positions including taking down, cleaning, cutting, threding along with GI fittings where ever replaced and required at site complete all as specified directed.
Supply and fixing in repair Sluice valve of size 150 mm dia CIass PN 1.6, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as specified and directed.
Supply and fixing in repair Sluice valve of size 100 mm dia CIass PN 1.6, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as specified and directed.
Material and labour in repair for construction of PCC block walling valve pit of size 900mmx 900mm x900mm(internal dimension) with precast cement concrete block of PCC 1:3:6(PCC 1:3:6) type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less then 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and directed by Engr-in-charge.
Repair of U/S non return valve of size 150 mm bore by replacing leather washer insertion with new ones all as directed.
Repair of U/S non return valve of size 80 mm bore by replacing leather washer insertion with new ones all as directed.
Supply and fixing in repairs Non return butterfly valve (NRV) ISI marked, gun metal body suitable for 150 mm dia pipe line including taking down old valve all as directed.
Supply and fixing in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of size 50 mm bore including taking down the unserviceable existing ones complete all as specified and directed.
Supply and fixing in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of size 40 mm bore including taking down the unserviceable existing ones complete all as specified and directed.
Clearing the bushes trunk girth not exceeding 1.0 mtrs around valve chambers and depositing at a distance nexceeding 50 mtrs from starting point.
Material and labour for Attending day to day water supply service related complaints like choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessary engineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed by Engineer-in-Charge.
Note for item No 31 :- (a) The contractor has to attend above mentioned job in any location of entire Air Force Stn Jalahalli West area
(b) The service tanks are positioned on roof top of multi storied buildings upto three storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc.
(c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate.
(d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard.
(e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate.
(f) In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(g) If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(h) The decision of the Accepting Officer in this regard shall be final and binding.
Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed by Engineer-in Charge suitable for up to 1000Ltrs cap of tanks.
Supply and fix in repairs lids for polyethylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed by Engineer-in Charge suitable for up to 1001 to 5000 Ltrs cap of tanks.
Supply and fix Nipple suitable for HDPE water tank.(Minimum weight 20 mm- 45gm)
Supply and fix Nipple suitable for HDPE water tank (Minimum weight 25mm- 65g
Supply and fix PVC water tank 500 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as directed incl disconnecting existing tank of any description and capacity and removal from site.
Supply and fix ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed with the 20 mm bores including taking down U/S ball valve set
Supply and fix ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed with the 15 mm bores including taking down U/S ball valve set
Supply & fix in repair Bib taps chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15 mm.
Supply and fixing in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of size 25 mm bore including taking down the unserviceable existing ones complete all as specified and directed.
Supply and fixing in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of size 20 mm bore including taking down the unserviceable existing ones complete all as specified and directed.
Supply and fixing in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of size 15 mm bore including taking down the unserviceable existing ones complete all as specified and directed.
Supply and fixing in repairs U/S foot valve cast iron of size 50 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specifed and directed.
Supply and fixing in repairs Non return butterfly valve (NRV) ISI marked, gun metal body suitable for 80 mm dia pipe line including taking down old valve all as directed.
Supply and fixing in repairs Non return butterfly valve (NRV) ISI marked, gun metal body suitable for 50 mm dia pipe line including taking down old valve all as directed.
Refixing of old serviceable GI tubing on wall/ceiling/under floor and in trenches of size 40 mm bore and connection in new or old positions including taking down, cleaning, cutting, threding along with GI fittings where ever replaced and required at site complete all as specified directed.
Refixing of old serviceable GI tubing on wall/ceiling/under floor and in trenches of size 25 mm bore and connection in new or old positions including taking down, cleaning, cutting, threding along with GI fittings where ever replaced and required at site complete all as specified directed.
Refixing of old serviceable GI tubing on wall/ceiling/under floor and in trenches of size 20 mm bore and connection in new or old positions including taking down, cleaning, cutting, threding along with GI fittings where ever replaced and required at site complete all as specified directed.
Refixing of old serviceable GI tubing on wall/ceiling/under floor and in trenches of size 15 mm bore and connection in new or old positions including taking down, cleaning, cutting, threding along with GI fittings where ever replaced and required at site complete all as specified directed.
Supply and fixing in repair Sluice valve of size 80 mm dia CIass PN 1.6, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as specified and directed.
Supply and fixing in repair Sluice valve of size 50 mm dia CIass PN 1.6, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as specified and directed.
Supply and fixing in repairs Non return butterfly valve (NRV) ISI marked, gun metal body suitable for 100 mm dia pipe line including taking down old valve all as directed.
Material and labour in repair for construction of PCC block walling valve pit of size 600mmx 600mm x600mm(internal dimension) with precast cement concrete block of PCC 1:3:6(PCC 1:3:6) type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less then 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and directed by Engr-in-charge.
Supply and fixing 25 mm dia Unplasticiced PVC Pipes of pressure rating of pressure rating 10kgf/cm2 fixed complete to wall,ceilings or in floors etc,any type of pipe.
Supply and fixing 20 mm dia Unplasticiced PVC Pipes of pressure rating of pressure rating 10kgf/cm2 fixed complete to wall,ceilings or in floors etc,any type of pipe.
Supply and fixing in repair UPVC Gate Valve of size 25 mm dia , ISI marked.
Supply and fixing in repair UPVC Gate Valve of size 20 mm dia, ISI marked.
Supply and fix ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed with the 25 mm bores including taking down U/S ball valve set
Supply and fix ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed with the 40 mm bores including taking down U/S ball valve set
Supply and fix PVC water tank 1000 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as directed incl disconnecting existing tank of any description and capacity and removal from site.
Supply and fixing in repairs U/S foot valve cast iron of size 80 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specifed and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth and getting out in soft/loose soil for laying of GI pipes complete all as specified and as directed.
Returning, filling in soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm in any type of soil complete all as specified and as directed.
Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Cutting the existing road/hard standing/chequered cement concrete tiling/PCC floorinf etc, not exceeding 50 CM wide and 50CM depth, for laying CI/GI/DI pipe line complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for Making good or where required for the road/hard standing/chequered cement concrete tiling/PCC floorinf etc, including necessary form work to exposed surfaces finished smooth and even complete all as specified and as directed.
Supply and lay in replacement of galvanised GI Tubing medium grade of 100 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Supply and lay in replacement of galvanised GI Tubing medium grade of 80 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Supply and lay in replacement of galvanised GI Tubing medium grade of 50 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Supply and lay in replacement of galvanised GI Tubing medium grade of 40 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Supply, Installing testing and commissioning in replacement LT starter panel board , double door, front and back openable of factory made cubical indoor type, fabricated out of 2 mm thick MS sheet with angle iron frame made out of 50x50 x6 mm at vertical corner & base of panel board mounted on 50x50x6 mm angle iron 60 cm long four legs and including suitable supports between the legs , provn of two ventilator with cooling fan of suitable size, duly tested as per IP 65 standards ,suitable for 415 V , 3 Phase 4 wire dust and vermine and weather proof, separate hinged door for each compartment with locking arrangement , grouted in PCC 1:2:4 type C1 complete duly powder coated with 7 tank process and comprising of the following:-
(a) Metering module with 300 Amp copper Bus bar , multifunction panel energy meter -01 No (for measuring current , voltage , KWH & PF), , CT's 400/5-03 Nos, LED indicating lamps -03 nos.
b) MCCB four pole adj type 36 KA, 250 A-01 No
c) MCCB three pole 36 KA, 100 A-03 No
d) Digital soft starter of motor capacity 40 HP/30 KW of Make : L&T, BCH, Schneider suitable for motor protection against overload , single phasing, reverse running, low voltage, unbalanced current etc -02 set.
Note : -1. The contractor shall be solely responsible and shall ensure due compliance before quoting the rate. 2. The unit quoted rate is deemed to include the items left over in above specification but essential to make the fully use of panel with 40 HP motors without claiming any extra cost..
Cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto three storrey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as "TANK CLEANED ON"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening. (ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(a) For RCC /PVC tank exceeding 200 litters and not exceeding 500 ltrs
(b) For RCC /PVC tank exceeding 501 litters and not exceeding 1000 ltrs
(c) For RCC /PVC tank exceeding 1001 litters and not exceeding 2000 ltrs
(d) For RCC /PVC tank exceeding 2001 litters and not exceeding 5000 ltrs
(e) For RCC /PVC tank exceeding 5001 litters and not exceeding 25000 ltrs
Material and labour Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coat of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers will be given as per requirement by the Engineer-in-Charge.
Supply and lay in replacement of galvanised GI Tubing medium grade of 25 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Supply and lay in replacement of galvanised GI Tubing medium grade of 20 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Supply and lay in replacement of galvanised GI Tubing medium grade of 15 mm dia in trenches/wall/floor/ceiling and connection in old or new position including taking down and also including fitting like socket / union / Tee / Reducer Nipple etc complete including taking down of existing unserviceable pipeline all as directed of following sizes Note: Excavation & earthwork shall be measured & paid seperately
Material and labour for painting of rising/distribution main, washout,over flow with arrow marked after preparation of good painted CI pipe 100 mm to 250 mm bore of any description and spary painting with two coats of synthetic enamel paint over one coat of red cxide zinc chrome primer incl cleaning, stopping and rubbing down and removing all drops, dirts etc.Note:-All arrangements for painting of any of pipe lines shall be arranged by the contractor and rate quoted as deemed in over all quoted rates.
Material and labour for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Material and labour for ribbed soil 8 cm below cable and 15 cm above cable for cushioning of cable and punned to 18 cm all as specified and directed. Note :- 1. Excavated soil shall shall be riddle by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches all as in cable cushioning. 2 Punned soil only measured for paymentpurposes.
Material and labour for XLPE LT cable of size 185 Sqmm 3 ½ core insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole and including taking down old unserviceable cable complete all as specified and directed Make :- Havells, Polycab, RPG Asian . Note:- (i) Excavation & earth work, ribbed soil in trenches as in cable cushioning , new bricks for cable protection shall be measured & paid seperatly in respective items here- in-after.
Supply, install, testing of commissioning of LT starter panel of suitable size made out of 16 gauge MS sheet weather proof duly powder coated mounted on frame made out of 32x32x6mm angle iron frame height not less than 50 cm duly painted with two coat of black enamel paint over a coat of red oxide primer, as per CPRI approved pattern including grouting in PCC 1:2:4 , necessary earth work , connections and testing complete in all respect all as specified and directed by Engr-in-charge and comprising of the following :- a) 4 strip Aluminium Bus bar of capacity 100 A, 60 CM long- 01 Set b) Starter for 7.5 HP submersible -02 Nos c) MCCB 63 A,4 P, 415 V-01 Nos d) Digital Voltmeter-01 Nos e) Digital Amperemeter -01 Nos f) Indicator lamp (RYB) - 01 set g) MCB TPN 32 A -02 Nos h) MCB SPN 32 A -02 Nos
Supply and fix PVC water tank 2000 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as directed incl disconnecting existing tank of any description and capacity and removal from site.
Material and labour for Making arrangement to flush out the existing pipe line of any type upto 50mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 100 to 101 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate.
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCCTanks all specified for tanks capacity of 200 to 500 Ltrs.
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCCTanks all specified for tanks capacity 501-1000 Ltrs.
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCCTanks all specified for tanks capacity 1001-2000 Ltrs.
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCCTanks all specified for tanks capacity 2001-5000 Ltrs.
Material and labour for preparation of old painted external surface by brooming down scrubbing with steel wire brush, scraping old distempered and painted surface and applying two coat of cement base paint to service tanks in building and under ground sump/ RCCTanks all specified for tanks capacity 5001-25000 Ltrs.
Supply ,Install, testing and commissioning in replacement of Smart control panel for dosing system with 3phase input supply and output capacity of minimum 6A and upgradable to 16A, Equipped with 20x4 Character LCD to display real time phase wise voltage. 5 mm LED Indication for fault detection including Under Voltage (380 Vac), Over load (440 Vac), Phase failure, Over Load. Weather proof IP54 enclosure indoor type complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 32x6 mm (up to 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, check nuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as specified and directed by Engr-in-charge.
Prasad and Suresh Constructions
RAMESH BABU CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .