Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹22.2 L+₹2.3 L (11.4%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance Higher than L1 bidder | |
| 3 | L3₹22.8 L+₹2.9 L (14.4%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Higher than L1 bidder | |
| 4 | L4₹23.7 L+₹3.8 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Higher than L1 bidder | |
| 5 | L5₹24.9 L+₹4.9 L (24.6%)Rejected-Finance | L5 | Rejected-Finance Higher than L1 bidder |
Tender Value
₹42.9 L
EMD Value
₹85,720
Closing Date
1 Dec 2023, 6:00 pmClosed
MAJ VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION FITTING AND FIXTURES AND ALL CONNECTED ITEMS IN OFFR MD QTR AND SOME CERTAIN AREA UNDER GE(I) KANPUR.
2023_MES_626654_1
GE(I)/KAN/T-63 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹85,720
Yes
3 Feb 2024
3 Nov 2023
8 Dec 2023
3 Nov 2023
1 Dec 2023
17 Nov 2023
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No-2 here in above but upto ceiling height and on surface at ceiling.
All as per srl item No-2 here in above but in existing conduit.
All as per srl item No-2 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit.
All as per srl item No-2 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in existing conduit.
All as per srl item No-2 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-2 here in above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit.
All as per srl item No-2 here in above but for one 5A socket outlet on the same board controlled by one switch.
All as per srl item No-2 here in above but for one 5A socket outlet on the same board controlled by one switch in existing conduit.
All as per srl item No-2 here in above but for one light point controlled by 2 nos two way switches.
All as per srl item No-2 here in above but for one light point controlled by 2 nos two way switches in existing conduit.
All as per srl item No-2 here in above but for one light/fan/bell point including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-2 here in above but for one socket outlet 5 amps on indipendent board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-2 here in above but for one socket outlet 5 amps on same board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-2 here in above but for one light point controlled by two, two way switches including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-2 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLSH) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
All as per srl item No-18 here in above but in existing concealed conduit .
All as per srl item No-18 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit.
All as per srl item No-18 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm in existing concealed conduit with earth wire 4 sqmm.
All as per srl item No-18 here in above but for cable of size 10 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm in & including concealed PVC conduit.
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLSH) of size 10 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts.
S&F switch piano flush button single pole one way 15/16 amps 230 Volts.
M&L for switch piano flush button single pole two way 5 amps 240 volts.
M&L for bell push flush button single pole one way 5 amps 240 volts.
M&L for socket 5 amps 5 pin flush type, 230 volts.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts.
M&L for ceiling rose surface bakelite 3 terminals.
S & F Lamp holder insulated body with back plate for dome batten fittings.
M&L for bell electric heahy duty Ding Dong type 230 volts single pole complete and all as specified.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts.
S&F switch modular type one way 1 module 16 amps 230 Volts.
M&L for bell push modular type 1 module one way 6 amps 240 volts.
Supply & fix in replacement hylem sheet cover 3mm thick of size 5''x5'' all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box.
All as per item No-37 above but of size 8"x5" .
All as per item No-37 above but of size 11"x9".
S&F in repair sunken box size 4"x4'' and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 7"x4" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 10"x8" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in replacement of wall mounted LED light fittings 20/22 watt, 6500K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed.
S&F in replacement of LED bulk head fitting with opal diffuser min 10 Watt, 6500 K, IP-65, with efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed.
S&F in replacement of LED mirror light fitting min 10 Watt Watt,1' long, with efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed.
S&F in replacement of LED light fitting recess mounted min 32 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed.
S&F in replacement of LED Post Top Lantern 35/40 watt warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection fixing with proper arrangements and making electrical connection complete all as specified & directed.
S&F in replacement of LED Post Top globe master made up of unbreakable polycarbonate suitable for mounting on gate with LED bulb 12 W with proper arrangements and making electrical connection complete all as specified and directed.
Supply and fix in replacement of High power LED wall security light 25 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd.
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts, complete with one single pole MCB of 20 amps earthing.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link of make Legrand or equivalent of make Havells/L&T fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification including 63 amp RCCB 1000 MA.
All as per srl item No 51 above but for 8 way.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size.
M&L MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 KA using thimbles of required size.
S & F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to cat pt No 607913 of Legrand or equivalent of make Havells complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor 10 sq. mm nominal cross section twin core for service connections all as required and directed.
All as per srl item No 56 but cable of size 6 Sqmm 2 core.
S & F in repair MCCB 4 Pole, 415V, 160 Amps with breaking capacity 25 KA complete all as specified & directed.
S & F in repair MCCB 4 Pole, 415V, 250 Amps with breaking capacity 25 KA complete all as specified & directed.
Supply and fix in repair LED bollard light 8/9 watt suitable for landscape lighting with high power LED as light source including making PCC foundation fixing with required fasteners, making electrical connection complete all as specified and directed.
S&F in replacement of protection case of MS angle iron 35x35x5mm for post top lantern fittings caged with MS wire netting of dia not less than 4 mm and weight of cage not less than 15 Kg as per site requirement with fixing arrangement including painting two coat of synthetic enamel paint over a coat of red oxide primer complete all as speciifed and directed.
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core.. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
S&F T-Bulb 10 watt B-22 bulb base 1000 lumen complete all as specified & directed.
DEO Traders
A.B.Enterprises
S B ENTERPRISES
Vee Key Enterprises
Preetpowercontrol
M/s A S Electrical
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .