Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.1 L+₹42,613 (1.80%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Eligible |
Tender Value
₹24.6 L
EMD Value
₹49,250
Closing Date
21 Jan 2022, 5:00 pmClosed
Executive Engineer Elect Div. PWD B and R Hisar
Executive Engineer Elect Div. PWD B and R Hisar
CONSTRUCTION OF NEW BUILDING IN GOVT. WOMEN COLLEGE AT LOHARU IN DISTT. BHIWANI (PDG. CCTV CAMERA/ EPABX/ LAN AND FIRE ALARM SYSTEM ONLY).
2022_HRY_202799_1
ect-GGN/Elect-HSR/100274
Open Tender
Electrical Works
Works
120 days
HISAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹49,250
Yes
9 Apr 2022
7 Jan 2022
24 Jan 2022
7 Jan 2022
21 Jan 2022
7 Jan 2022
Amount
SITC of 1.5sqmm PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (Based on HSR 23.5.6.1) Make: Havells /Polycab/Finolex
SITC of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work (Based on HSR 23.7.6) Make: AKG/ Diplast/ Polypack. i) 25mm dia
32mm dia
SITC Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (Based on HSR 23.23.9) (Make: D-link/ MOLEX/ AMP.
EPBAX SYSTEM: SITC IP-PBX with Configuration, User expandable up to 256 Ports Lines with Following Configuration: - 42 Analog Users 8 digital users System should support ISDN PRI – 01, 04 Analog Trunks 01 Operator Console. a) Remote Maintenance Facility, b) Web Based Management Software c) Call Accounting Software-01, d) DISA & DOSA Facility, e) Wall / Rack Mountable System, f) Call Control Server / Application should be equipped with Intel / Pentium Based Processer including cost of all material and Labour required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. Make : Avaya /Siemens /MATRIX.
SITC Digital Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work Make / Avaya/ Siemens/ MATRIX.
SITC Analog Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work. Make Beetal M71 /MATRIX/ AVAYA.
SITC Single Telephone I/O including face plate complete in all respect. Make Dlink/AMP/MOLEX.
SITC of MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection. Make Krone or equivalent. i) 20 pair MDF unit
100 pair MDF unit
SITC of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect. i) 2 pair telephone wire
20 pair telephone wire
LAN SYSTEM: SITC UTP Cat-6 information outlet complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: D-link/MOLEX/AMP.
SITC Face plate (Single / Dual) complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work. Make: D-link/MOLEX/AMP.
SITC UTP Cat - Mounting Patch Cords complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: D-link/MOLEX/ AMP. i) 3 ft length
5 ft length
SITC Layer 3 Switch Should have minimum 280 GBPS of higher switching capacity Port Standards: IEEE 802.3 10BASE-T Ethernet (twisted-pair copper), IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper), IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted- pair copper), IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3, Auto-negotiation, IEEE 802.3x Flow Control, Interface: 24 10/100/1000Mbps BASE-Tx,4 SFP Combo and 4 SFP+ :- UL,CE/IC,FCC, ROHS II. Protocol:- SNMP v1/v2/v3, IGMP v1/ MLD V2, DHCP Safety client/ Relay, Layer 2 & Layer 3 ACL, Surge protection ,Internal/External Redundant Power Supply, SD Card slot/USB/External flash for easy file store & restoration like firmware, configuration file, boot image, syslog, 1GB DRAM and 1GB flash, Management Port & Alarm Port, Protocols :ARP,Gratuitous ARP, 802.1Q VLAN encapsulation, 802.1v Protocol-based VLAN and MAC based Vlans, GVRP, QinQ, Multicast VLAN, 802.1D STP, MSTP, RSTP & Loopback Detection Layer 3 Routing Features :should support Static routing for IPv4 and IPv6, RIP for IPv4 and RIPng for IPv6, OSPF,OSPF v3, BGP4, BGP4+ IS-IS v4/V6 and MPLS from day 1, PIM-SM/PIM-DM/PIM-SDM/PIM-SMv6,DVMRP v3 and MSDP, VRRP v2 & V3 should support 802.1p priority queuing with 8 queues per port. Non Blocking Architecture of minimum 128 GBPS Backplane & 94 MPPS throuput. Make/ Allied Telesis / Extreme/ARISTA/JUNIFER.
FIRE ALARM & PA SYSTEM:- SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Cerberus by siemens/Honeywell Morley ZXE Series/EDWARDS.
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Siemens Cerberus OH921+DB-11 / Honeywell Morley HM-PTSE+B501/EDWARDS.
SITC of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring complete in all respect. Make: / Siemens Cerberus/ Morley/Edwards.
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make Siemens cerberus/ Morely/Edwards.
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the ob in all respect upto the entire satisfaction of Engineer - in - charge of work. Make: Siemens Cerberus / Morley/ Edwards.
Supply Installation Testing Commissioning of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification. Makes :Siemens Cerberus / Morley/ EDWARDS.
Supply Installation Testing Commissioning of Addressable monitor Module for monitoring of a line with EOL resistor/potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (in case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Makes:Siemens cerberus HTRI-M/ Morley MI-DMMI/ EDWARDS.
SITC 2 KVA Online UPS with isolation transformer suitable for single phase AC Input and single Phase AC output, Floor Mounted type Rating of UPS 2 KVA, Indicative Backup time 2 hours Complete in all respect including bettery etc. MAKE: APC/ ELNOVA/ ETON.
SITC of Analog Addressable type active repeater fire alarm panel with backlite LCD Display, having controls for reset, mute, accept, silence alarms and self rest conforming to BS5839 standards and duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. Make:- Cerberus by Siemens, Morley ZxRA, Edwards 3-LCD-ANN.
SITC Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect Make Siemens cerberus/ Morely/ Edwards.
SITC 17 U rack including power distribution kit, cable Manager complete in all respect. Make: Valrack/ Comrack/ Ritall/ CP PLUS.
CCTV SYSTEM: Supply Installation testing commissioing of lmage device/ Sensor - 1/3" Progressive Scan CCD / Progressive Scan CMOS or Better Dome camera Resolution - 2 Megapixel (1920 x 1080) or better Frame rate Up to 30 fps or better Lens Type - 3 to 9 mm auto varifocal lens Motorized IR Light & Distance - Ir Range upto 30 mtrs or better Signal to Noise Raio - >50db Minimum lllumination - 0.3Lx Color; lR LED ON 0 .0 Lux or better Day Night - Auto Day/Night with switchable IR cut filter Video Compression - H.265,H.264,M-JPEG Camera should have Multiple Streaming- Min. Triple Edge Based Analytics Storage - SD Card slot should be expandable up to 128 GB System Compatibitity - ONVlF Profite S&G Privacy Masking - Minimum 4 Privacy zones or higher Protocols - lPv4/lPv6, HTTP, HTTPS, TCP/lP, UDP, UPnP, ICMP, RTSP,RTP, SMTP, NTP, DHCP, DNS, DDNS Additional Features Noise Reduction - Digitat Noise Reduction on/off. WDR -120dB WDR Atarm Input/Output - 1 Alarm Input, 1 ALarm OutPut Audio Input/Output - 1 audio input/1 audio outPut Operating Environment – lndoor/ Outdoor Operating Temperature -0C to 50 c lngress protection & vandaI resident standards - lP66 or better and IK10 or better UL,FCC,EN complete in all respect upto entire satisfaction Engineer in charge of works. Make:HONEYWELL /Axis/SONY/AVIGILON.
Supply Installation testing commissioing of IP IR PTZ dome camera PoE enabled (High definition) lmage device/Sensor - 1/3" Progressive Scan CCD/ Progressive scan CMOS or better PTZ cameraResotution - 2 Megapixel, 1080p (1920x1080) or betterOptical Zoom 30X & Digital Zoom: 12XlR Light & Distance - lR range up to 150 Mtrs. Or betterSignal to Noise Ratio - >_50 dB (AGC OFF )PAN & Tilt travel - Pan 360 endless Tilt 0 to -90 (Auto Flip)Minimum lIIumination - 0.3Lx Color and B/W 0.01LxDay Night - Auto Day/Night with Auto lR-CUT fitter with auto switch EncodingVideo Compression - H.265 MJPEG Triple Stream encodingFrame Rate - Main Frame 30 FPS in all resolution or betterAudio Compression - G.711/G.726Edge Based AnalyticsStorage - SD Card shoutd be expandabte up to 128 GBProtocols - lPv4/lPv6, TCP/lP, UDP, RTP,RTSP, HTTP, HTTPS, ICMP,SMTP, NTP, DHCP, UPnP, IGMP,SNMP,IEEE 802.1 XSystem Compatibitity - ONVlF Profite S & GPrivacy Zone - Minimum 4 Privacy zones or higherAdditional FeaturesNoise Reduction-Digitat Noise Reduction on/off .WDR -90dB True WDR or betterAlarm Input,/ Alarm Output-1 Alarm Input, 1 Alarm Output.
Supply,Installation,Testing & Commissioning of lmage device/ Sensor - 1/3" Progressive Scan CCD / Progressive Scan CMOS or Better Bullet cameraResolution - 2 Megapixel (1920 x 1080) or betterFrame rate Up to 30 fps or betterLens Type - 3 to 9 mm auto varifocal lens MotorizedIR Light & Distance - Ir Range upto 30 mtrs or betterSignal to Noise Raio - >50db Minimum lllumination - 0.3Lx Color; lR LED ON 0 .0 Lux or betterDay Night - Auto Day/Night with switchable IR cut filterVideo Compression - H.265,H.264,M-JPEG Camera should have Multiple Streaming- Min. TripleEdge Based Analytics Storage - SD Card slot should be expandable up to 128 GBSystem Compatibitity - ONVlF Profite S&GPrivacy Masking - Minimum 4 Privacy zones or higherProtocols - lPv4/lPv6, HTTP, HTTPS, TCP/lP, UDP, UPnP, ICMP, RTSP,RTP, SMTP, NTP, DHCP, DNS, DDNSAdditional FeaturesNoise Reduction - Digitat Noise Reduction on/off.WDR -120dB WDRAtarm Input/Output - 1 Alarm Input, 1 ALarm OutPutAudio Input/Output - 1 audio input/1 audio outPut Environment Operating Environment – lndoor/ Outdoor Operating Temperature -0C to 50 c lngress protection & vandaI resident standards - lP66 or better and IK10 or better Certificates: UL, FCC, EN complete in all respect upto entire satisfaction Engineer in charge of works.Make:HONEYWELL /Axis/Sony/AVIGILON.
Supply of Network Video Recorder 32 Channel Network recorder With HD to a maximum of 32 IP cameras,The recorders can be installed with a maximum of internal HDDs for video storage. Option of a HDDs for storage, plus a DVD burner for video export. Max. capacity per HDD: 16 TB. 1 no. E-SATA supported. The recorders comes with a built-in PoE+ switch as an option. 16 alarm i/p & relay o/p. Simultaneous 1/4/9/16 channels playback. H.265/H.264/MJPEG supported. iPhone/Android support. Maximum incoming bandwidth of 320 Mbps. Maximum recording bandwidth of 320 Mbps. 1 I/O for audio. 1 VGA & 2 HDMI outputs. CE, UL & FCC certified Make:HONEYWELL /Axis/Sony/AVIGILON.
Supply of Layer-2 POE plus Gigabit Ethernet 1RU chassis with 24 PoE 10/100/1000 BaseT ports and 4 Gigabit SFP ports. Includes an internal AC power supply 370W atleast or higher power budget) with a power cord, manuals access card, and RJ-45 to DB-9 adaptor.The Access Switch should have 4 ports of 1 G SFP.The Access Switch should provide Non-Blocking switch fabric capacity of 56 Gbps or more. L-2 switch should provide wire-speed packet forwarding of 41 Mpps or more. L-2 Switch should support min 16K MAC addresses and min 4000 active VLANs. Make: ALLIED/ EXTREME/ SCHNEIDER.
Supply of 9U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit Make: Netrack/ Comrack/ D-Link/ C PLUS.
Supply of 43" LED Monitor, Full HD, HDMI Port, Component Video Inputs, 1 Digital Audio Out, Make: Sony/ Panasonic/ Samsung/ LG.
Supply of 2 KVA UPS Overvoltage cut-off device (OVCD),Support for up to 160 AH external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for IndianEnvironmental Condition andfor Optimized BatteryPerformance. UPS would support SNMP Mnagaer and web browser On Line With 1 hour Backup. MAKE APC/ ETON/ ELNOVA.
Supply of 24-port 19" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19" 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated. Make (R&M/ MOLEX/Seimon)
Supply of CAT 6 UTP Cable.Transmission frequency of 250 MHz (Minimum),cable Should be 4 pair and Cable should be jacket FR PVC Lbp 69% required with certification report. Make: Panduit/R&M/Molax/D-LINK)
Supply of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: BEC, AKG, Ravindra / Diplast .
Supply of 2 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells
ASHU TRADING COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .