Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.3 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 1 | Accepted-AOC L1 | |
| 2 | 2₹38.8 L+₹4.5 L (13.2%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹38.8 L+₹4.6 L (13.4%)Rejected-Finance | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹48.0 L+₹13.7 L (40.0%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 4 | Rejected-Finance Not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Lucknow
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
UPGRADATION OF 11 KV BREAKERS AT NEW MRS UNDER GE E/M LUCKNOW
2023_MES_577369_1
CWE/LKO/EM/T-91 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
22 Mar 2023
25 Jan 2023
22 Feb 2023
25 Jan 2023
20 Feb 2023
8 Feb 2023
25 Jan 2023 - 8 Feb 2023
Amount
Supplying, installing, testing and commissioning of Indoor arc flash protected Draw-Out with roll on floor type Vacuum Circuit Breaker Panel , rated for 11kV, 1250Amp, 26.3kA/3-sec, comprising of 1 No. Incomer and 03 Nos. Outgoing VCB Panels confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 26.3kA for 1sec, Accessibility Class LSC2B-PM Class, comprising of 1250Amp, continuous rated Copper busbars and droppers, 02 Nos . Rack-In-Rack-Out Handles, structure made from AluZinc/GI sheets to prevent corrosion and rusting.The complete panel including HT and LT chamber with FRLS wiring shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. Make ABB/Seimens/Schneider The Board shall consist of following panels:- (A) 01 x Incomer Panel comprising of :- (i) 11kV, 1250Amp, 26.3kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100 with roll on floor type Vacuum Circuit Breaker having 03 Nos. vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (110VDC).
(ii) Current Transformers 11kV, 300-150/1-1-1, Core1: Class 5P10, 2.5VA, Core2: Class 0.5, 2.5VA, Core3: Class PS-X - Set of 03 Nos. The 'PS' core will be of suitable knee point voltage and ratio so as to succesfully implement Transformer Differential protection scheme for the upstream exisitng power transformer. (iii) Potential Transformers, Draw-out type for easy maintenance, 11kV/rt3:110V/rt3, 50VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation - Set of 03 Nos.
(iv) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT+04PT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (a) Directional over-current or earth-fault in any of the three phases, (b) circuit-breaker-failure alarm, (c) interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. (d) Integrted arc flash protection with current and light sensing The relay shall be communicable on IEC 61850 GOOSE platform over RJ-45/USB/FO port, and fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Line-Voltage, Breaker On/Off/Spring.Chrgd, Trip Circuit Failure (from TCS relay), AC Supply Fail, PT Fuse failure relay, Local-Remote etc. and display locally on a built-in back-lit LCD screen with mimic as a Single-Line-Diagram with power & frequency measurements and suitably labelled status LEDs. Relay setting should be possible through inbuilt software or through addtional software supplied by the relay manufacturer. Make of the relay shall be same as make of switchgear panels.
(v) Metering Equipment including:- (a) 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), (b) 01 No Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port. (vi) LED Indications :- (a) Breaker ON/OFF/TRIP/Spring-Charged, (b) R-Y-B, (c) DC Available LED with push-button (d) Trip Circuit Healthy
(vii) 06-Window Annunciator with Hooter to indicate following alarms :- (a) OC Trip, (b) EF Trip (c) Trip Circuit Failure, (d) Inter-Tripping Fault, (e) PT Fuse Failure The Annunciator will be complete with required Acknowledge/Test buttons as required
(viii) Control Equipment incl. :- (a) 01 x TNC Switch, (b) 01 x Local/Remote Switch, (c) 01 x Emergency Trip Push Button, (d) MCBs for AC (e) MCBs for DC (f) Heater Switch with Thermostat - 01no. (g) 3-pin socket with ON/OFF switch - 01no. (h) CFL Lamp with ON/OFF switch - 01no.
(ix) Flush mounted Auxillary Protection Relays incl:- (a) Trip Circuit Supervision Relay, (b) Master trip Relay, (c) PT Fuse failure relay. (d) DC Supervision Scheme (x) Suitable Disconnecting Link type terminal arrangement shall be provided for interfacing PS-Class CTs installed in the panel with Transformer differential relay situated in the 33kV CRP for achieving the required protection.
(B) 03 x Outgoing Panel, each comprising of :- (i) 11kV, 1250Amp, 26.3KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03nos. vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (110VDC). (ii) Current Transformers 11kV, 200-100/1-1, Core1: Class 5P10, 2.5VA, Core2: Class 0.5, 2.5VA - Set of 03 Nos.
(iii) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having 04CT Inputs with microprocessor based protection scheme for tripping the breaker on various faults like (a) over-current or earth-fault in any of the three phases, (b) circuit-breaker-failure alarm, (c) interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol. (d) Integrted arc flash protection with current and light sensing The relay shall be communicable on IEC 61850 GOOSE platform over RJ-45/USB/FO port, and fully integrated with the feeder, internally capturing feeder statuses incl. various status, Line-Current, Breaker On/Off/Spring.Chrgd, Trip Circuit Failure (from TCS relay), Local-Remote etc. and display locally on a built-in back-lit LCD screen with mimic as a Single-Line-Diagram with current measurements and suitably labelled status LEDs. Relay setting should be possible through inbuilt software or through addtional software supplied by the relay manufacturer.
(iv) Metering Equipment including:- (a) 01 x Digital Ammeter (Acc.Cl.0.5) (v) LED Indications - (a) Breaker ON/OFF/TRIP/Spring-Charged, (b) Trip Circuit Healthy (vi) 04-Window Annunciator with Hooter to indicate following alarms :- (a) OC Trip, (b) EF Trip (c) Trip Circuit Failure, (d) Inter-Tripping Fault, The Annunciator will be complete with required Acknowledge/Test buttons as required
(vii) Control Equipment incl. (a) 01 x TNC Switch, (b) 01 x Emergency Trip Push Button, (c) 01 x Local/Remote Switch, (d) MCBs for AC/DC isolation (e) Heater Switch with Thermostat - 01no. (f) 3-pin socket with ON/OFF switch - 01no. (g) CFL Lamp with ON/OFF switch - 01no. (viii) Flush mounted Auxillary Protection Relays incl. (a) Trip Circuit Supervision Relay, (b) Master trip Relay,
(C) The panel shall be complete with all allied items and accessories, including:- (i) Cost of construction of foundation as per manufacturer design, including foundation frame (supplied by OEM), channels etc. for HT Panel as required at site are deemed to be included in the quoted rate. (ii) Each VCB panel being floor-mounted, air-insulated, fully-compartmentalizeds The OEM shall supervise and certify the commissioning/charging of equipment. (iii) Foundation frames shall be inclusive in the scope of supply of OEM. (iv) All Outgoing VCBs will have inter-tripping logic in place to ensure that Incomer breaker immediately trips in case of failure of opening of outgoing VCB experiencing feeder fault. Special and dedicated Alarm shall be in place to issued the user. This facility should be implemented over soft-logic, and can be disabled by authorized personnel without requiring any on-site re-wiring.
Note:- (i) License parter, system integrator, panel builder, half-panel is not allowed for 11kV VCB Panel. All works shall be done at own works. (ii) All items will be transported in wooden packaging to avoid any damage. Acceptance of material will be discretion of GE. Contractor has to remove the material in case of rejection of material at no extra cost. (iii) Factory acceptance test shall be carried out for 11 KV HT VCB Panels. (iv) The incommer panel will be connected with existing AREVA buscoupler , cost of fabrication of adaptor panel made of MS CRCA sheet 16 gauge thick duly painted matching with VCB including alteration/couple and matching with bus bar required at site shall be deemed to be included in the quoted rate. (v) Cost of disconnection of existing HT cables from existing RMU and taking out from duct and loop and reconnection with new VCB panels shall deemed to be included in the quoted rate (HT Cable and Joints required at site shall be measured and paid separately under respective items of schedule).
Supplying, laying, jointing, testing and commissioning HT under ground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts earthed cross sectional area 185 Sqmm , 3 core ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles etc complete all as specified and directed.
All as per item No 2 here-in before but cross sectional area 120 Sqmm , 3 core
S&F Cold shrinkable straight through joint kit with all accessories suitable for 11 KV (earth) HT XLPE cable of size 120 to 185 sqmm, 3 core incl cutting the userviceable portion and jointing cable in RYB phase sequence and testing complete as specified and dierecd .
S&F cold shrinkable, in door type, cable termination kit with all accessories suitable for 11 KV (earth) HT XLPE Cable of size 120 to 185 Sq mm 3 core incl disconnecting /connecting the cable in RYB phase sequence in RMU/pole incl cutting the unserviceable portion and testing after connection in all respect etc complete as specified and dierected .
M&L Earthing in replacement complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
Disconnecting electrically and mechanically existing 5 way RMU and re-installation, commissioning and testing at new site complete all as directed by Engr-in-charge.
Supply installation & commissioning of SCR Controlled Automatic 30V/25A Float Cum Boost battery Charger and D.C. Distribution Board in a Common Cubicle.The Charger is suitable for 230V +/-10% Single Phase AC Input and the Output is suitable to Float/Boost Charge 30V ,100AH Batteries and also supply Load. The Output remains constant within +/- 2 % for AC Input Voltage variation 230V +/- 10% and Load variation 0-100 %.DC distribution board provided of 63 Amps , DP MCB as incommer and 03 Nos, 16/20 Amps DP MCB for outgoing including 30Volt 100AH SMF VRLA Battery Bank consisting of 15 Cells of 2Volt 100AH capacity complete with copper Inter cell connectors, SS Nut Bolts & Washers FCBC and DCDB to be Housed in Sheet Steel Cubical Cabinet.Battery Charger will be divided into two compartments, Upper Compartment houses the Battery charger and Lower one suitable to house the batteries complete all as specified and directed.
M/S HINA ELECTRICALS
Prime power system
M/S S.B. Singh and Sons
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .