Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.9 L+₹3.7 L (8.68%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹46.6 L+₹4.4 L (10.4%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹47.9 L+₹5.7 L (13.6%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹48.1 L+₹5.9 L (13.9%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
5 Dec 2022, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
PROVN OF 66 STREET LIGHTS ALONGWITH POLES FROM TRIMULGHERRY SIGNAL TO RKPURAM BRIDGE AND PROVN OF 500 KVA TRANSFORMER FOR AUGMENTATION OF ELECTRIC SUP FOR INSTALLATION OF MRI SCANNER AND CONNECTED WORKS AT MH SECBAD UNDER AGE EM-II OF GE (U) SECBAD
2022_MES_562196_1
GE(U)/SEC/TOKEN/48 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹99,000
Yes
15 Jun 2023
9 Nov 2022
12 Dec 2022
9 Nov 2022
5 Dec 2022
23 Nov 2022
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed. Note: Any damages to the existing water line/ HT/LT/OFC Cables etc is responsible of contractor for repair/replacement.
All as per item No 1 above but depth exc 1.5 mtr but not exc 3 mtr.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and spreading of riddled earth sand in trenches/ transformer yard/ two pole structure yard for cable protection complete all as directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of old size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
M&L for cement concrete in foundation (1:4;8) type D2 using 40 mm graded broken stone aggregate for base or foundation complete as specified
M&L of PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary formwork complete all as specified and as directed.
Supply, laying, connecting by using lugs, nuts & bolts, testing LT UG cable XLPE insulated 1100 volts grade heavy duty 4 core 10 Sqmm with aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip and overall PVC sheathed, nominal cross sectional area incl connecting and testing, complete all as specified and as directed. Note : Earthwork, cable protection, pipe etc shall be measured and paid for separately under relevant items.
S&F LED Street light fixture 90 watt made of pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, cable gland is used for maintaining ingress protection, epoxy powder coated siemens grey finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistant fixed to the housing with SS screws, high efficiency long life LED chip in modules with lumen efficacy of >110 lm/W with PC lens and system lumen 9000 (system efficacy>100 lm/W). Powered by built in electronic LED driver with APFC (SMPS) based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over voltage protection, surge voltage protection, CCT 5700, CRI>70, THD<10%, PF>95, IP66, IK07 life class of 50,000 hrs @ L70, Operating Temperature : 10 to +10 Deg.C, Input Rated voltage : 240 VAC/50 Hz, Driver safety requirement standards : IS 15885-2-13, Test report to be submitted, driver performance requirements : IS 16104, Test report to be submitted, Photo biological safety norms : IS 16108, test certificate to be submitted, certification : LM 79 for luminaries LM 80 for LED Source. Make : HAVELLS/PHILIPS/BAJAJ/POLYCAB/CROMPTON as approved by GE.
S&F of 120 watt LED flood light, non-integral asymmetric type flood light with die cast aluminium housing with IP 65 protection flood light fittings. Make : HAVELLS/PHILIPS/BAJAJ/POLYCAB/CROMPTON as approved by GE.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE pipe upto 75 mm dia of max length 15 m including jointing materials to carry LT UG cables of size upto95 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed including refilling and making good of disturbed surface . Note : Quoted rate shall deemed to be Inclusive of HDPE pipe and shall deemed to be inclusive of necessary machinaries required for the above work
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-09 (7.5 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L for service wire of copper conductor 3 core X1.0 Sqmm including PVC conduit 15 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . ( Used for connection of street light from Junction box)
S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts, 32 AMPS made out of polycarbonate or bakelite and 1 No MCB SP of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs and PVC glands, fixed on pole by means of 2 SETS OF clamps complete all as specified and as directed.
M&L for street light bracket made out of 40 mm dia GI pipe medium grade 1.5 mtr long complete with 2 sets of FI clamps made out of 40x5 MS flat & nuts, bolts & washer including painting to clamp two coat of aluminium silver paint over a coat of primer complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as required for laying / protection of cable , fixing of light etc and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L Earthing complete with galvanized steel plate of size 60CMX60CMX6MM buried directly in ground vertically to a depth not less then 1.25 meter below normal ground level connected to galvanized earth STRIP by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit, charcoal common salt, Earthing lead 32 x6 mm galvanized strip up to 7.5m, 20mm dia medium grade GI watering pipe, G.I. protection pipe 40 mm dia up to 7.5m long, PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-1991 (part-I)
Note : The unit rate shall include for excavation & earth work in soft & loose soil PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @ 150mm C/C both way 40 mm dia light grade GI pipe up to 7.5 mtr long 20mm dia medium grade GI watering pipe wiremesh complete with addition to item No-1(a) to (f) of premble (note) under subheading earthing specified on SSR-II 2020.
M&L of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
Supply and installation of double wound copper transformer step step down, outdoor type complete with standard fittings, primary voltage of HT 11000 Volts and secondary LT 433 volts, 3 Phase 4 wire with frequency 50 c/s. Provided with 5 No of off load tappings on HT side to vary secondary voltage within range of +7.5% to - 2.5% (in steps of 2.5%), star delta connections with vector group of Dyn 11, Impedance of 5% and including first filling of transformer oil as per IS:335 and color coating with one coat of primer and two coats of BS grey colour and including PCC foundation. Losses all as per IS:1180 (Level - ii) of capacity of 500 KVA with the following accessories :-
(a) Rating and Terminal marking plate- one (b) Earthing Terminal- Two (c) Lifting Lugs- Two (d) Drain valve with Blanking plate - One (e) Filter Valve with blanking plate- One (f) Conservator-One (g) Oil Level indicator with minimum marking (h) Dehydrating breather-One (j) Air Release devise - One (k) Thermometer Pocket-One (l) Pressure relief valve - One (m) Roller unidirectional-Four (n) HV side Bare bushing and LV side cable end Box (o) Separate Brought out Neutral Terminal (p) Off Circuit Tap Changer (q) 100 MM dia stem type Thermometer (r) Foundation for Transformer of size : 1.5 M X 2 MX 2 M Make: ESENNAR / HIT / ABB / SCHNEIDER / BHEL / VOLTAMP
Note: 1.commissioning of the transformer to be done by SEI / EI as detailed. Contractor should intimate one month in advance for commissioning of the same. Necessary arrangement for testing to be done by the contractor. Rates for the same deemed to be included in the quoted rate. 2. Factory inspection and factory testing of the transformer to be done by the rep of Accepting Officer. 3. contractor should submit the drawing of the transformer based on IS and energy level mentioned in BOQ and take necessary approval from Accepting officer before finalisation order to the manufacturer. 4. Quoted rates are deemed to be inclusive of all accessories required for proper functioning of Transformer.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 70 sqmm to 120 sqmm
Advance Maintenance Free GI SAFE EARTHING Electrode with PIPE of not less than 50 mmOuter dia (THICKNESS NOT LESS THAN 2.5 MM) and two meter length. The electrode should be of galvanised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 X 6 mm 7.5 m. The GI electrode shall be pre filled with crystalline conductive material (CCM). The GI electrode shall be surrounded with 25 kg Back fill compound to provide maximum contact between the electrode and back fill compound should be eco friendly and having RoHs certification. GI Electrode shall be tested from CPRI. The earthing pit should be cover with PCC 1:2::4 B1 cover of 300 X 300 mm complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc by using 32 X 6 mm galvanised iron strip.
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100mm all arround ,separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cable up to 185 Sqmm 3.5 core in and out, incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the folowing :-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240.0 sq mm 3.5 core
M&L filling sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e. 18 cm) shall be measured for payment.
Supply and laying HDPE pipe 75 mm pn 10 ISI marked along with all accessories like socket bend couplers etc conforming to IS 14930 Part II complete with fitting and cutting , jointing etc direct in ground , wall , floor complete all as directed.
L and S ENTERPRISES
vvcenterprises
Srinivash Engineers
DPS sales and services india
SANJEEV CONSTRUCTIONS
omsai thermax engineers
POWER CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .