| 1 | L1₹62.2 LAccepted-AOC NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹63.0 L+₹77,780 (1.25%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹84.1 L+₹21.8 L (35.1%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | L3 | Rejected-Finance 3rd lowest bidder |
| Sl No | Description | Qty | Unit | NARAYAN CHANDRA DAS L1 | CHAKRABORTY ENTERPRISE L3 | M/s Singh Electrical Works L2 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of floor/wall mounted cubicle type indoor compartmentalized 415V., 50 Hz. dust & moisture proof LT Distribution panel board with following electrical accessories fabricated from 14 SWG CRCA sheet with MS angle frame as requried. The base of panel should be made with 75 x 40 x 4.4 mm MS channel and also RCC structure should be made as per the suitable size for floor mounting condition. The panel should have adequate strength & space to accommodate the incoming & outgoing switches and bus-bars with all interconnection in between the switches and bus-bars with copper flat / flexible wire of suitable capacity. The panel should be provided with cable alley for facilitating connection of all the incoming & outgoing XLPE Cables with termination arrangement by S&F copper terminal stud / bolt of required sizes. The panel with earthing attachment. The panel is to be painted with powder coated paint as per direction of EIC. The panel should be CPRI tested. The panel board should consist with the followings:- | 1 | Item | 8,25,000 ₹8,25,000 | 12,05,000 ₹12,05,000 | 1,12,293 ₹1,12,293 Lowest |
| 1.01(A) INCOMER & BUSCOUPLER | ||||||
| 1.02415V, 630 Amp 50 KA 4-Pole MCCB with microprocessor release (Relese range : 250 - 630A) and LSIGN Protection with proper fault indication, extended rotary handle, incomer side spreader terminals (Min 3 Nos. Cable Termination), additional spare contracts for ON, OFF & Trip with Electrical & Mechanical Inter lock [Make - ABB / Schneider / Legrand /Siemens ] - 3 Sets. | ||||||
| 1.03(B) BUSBAR CHAMBER | ||||||
| 1.04S&F 800 Amp capacity 99.9% - 99.5% electrolytic tinned copper 4 bar bus bar [size of flat 4 x 80 mm x 10 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars - 1set. | ||||||
| 1.05(C) OUTGOING | ||||||
| 1.06i) S&F of 415V, 320 Amp. 50 KA 4-Pole MCCB with microprocessor release (Relese range : 120 - 320A) and LSIGN Protection with proper fault indication, extended rotary handle, outgoing side spreader terminals, additional spare contracts for ON, OFF & Trip and Mechanical inter lock . [Make - ABB / Schneider / Legrand / Siemens ] - 02 Sets. | ||||||
| 1.07ii) S&F of 415V, 250 Amp. 50 KA 4-Pole MCCB with microprocessor release (Relese range : 63 - 160A) and LSIGN Protection with proper fault indication, extended rotary handle, outgoing side spreader terminals, additional spare contracts for ON, OFF & Trip and Mechanical inter lock . [Make - ABB / Schneider / Legrand / Siemens ] - 02 Sets. | ||||||
| 1.08ii) S&F of 415V, 100 - 125 Amp. 50 KA 4-Pole MCCB with microprocessor release (Relese range : 40 - 100A) and LSIGN Protection with proper fault indication, extended rotary handle, outgoing side spreader terminals, additional spare contracts for ON, OFF & Trip and Mechanical inter lock . [Make - ABB / Schneider / Legrand / Siemens ] - 06 Sets. | ||||||
| 1.09(D) METERING | ||||||
Tender Value
₹63.5 L
EMD Value
₹1.3 L
Closing Date
10 Feb 2026, 12:00 pmClosed
Exe. Engr.-I, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Electrical Installation works for the project- Repair, rehabilitation and retrofitting of distressed R.C.C. structure and other ancillary work of Ronald Ross and Cardiology Building at IPGMER-SSKM Hospital
2025_WBPWD_972521_1
WBPWD/EE-I/KSHED/Q84/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.3 L
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
2 Sept 2026
11 Dec 2025
12 Feb 2026
11 Dec 2025
10 Feb 2026
20 Dec 2025
19 Dec 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .