Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.0 L+₹5.5 L (16.8%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹38.9 L+₹6.4 L (19.6%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹40.8 L+₹8.3 L (25.5%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹43.4 L+₹10.8 L (33.3%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹37.8 L
EMD Value
₹75,600
Closing Date
3 Feb 2022, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/REPLACEMENT OF UNSV WATER SUPPLY PIPE LINE, BOREWELL AND CLEANING OF OHT AND UG SUMPS INCLUDING DAY TO DAY MAINTENANCE OF EXTERNAL WATER SUPPLY SYSTEM AT ZONE-1C AT BOWENPALLY AREA UNDER AGE E/M NO-1 OF GE (U) SECUNDERABAD
2022_MES_500227_1
GE(U)/SEC/TOKEN/62 OF 2021-2022
Open Tender
Civil Works - Water Works
Item Rate
180 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER UTILITY SECUNDERABAD
₹75,600
Yes
30 Aug 2022
7 Jan 2022
10 Feb 2022
7 Jan 2022
3 Feb 2022
21 Jan 2022
Amount
M&L for attending repair/rectification of external water supply complaints of GI/CI/DI/PP-R Pipe lines, sluice valves, gate valves of any type and size, Viz any type of leakages, no water supply and other water related complaints including transportation from complaint cell to complaint locations and back to complaint cell along with necessory T&P with provision of necessary excavation, returning and filling in as required at site, tightening of loose joints of union, elbow, sockets etc, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position including replacement of GI unions/sockets/nipples etc as required at site under Zone I C of AGE EM No.I areas and the following type of complaints all as specified and directed.
All as per item No 1 here-in-before for GI tubing upto 32mm bore
All as per item No 1 here-in-before but for GI tubing 40 mm bore to 50 mm bore
All as per item No 1 here-in-before but for GI tubing 80 mm bore to 110 mm bore
Notes for Sl item No 1 to 1.03:- (a) The contractor will be alloted complaints at MES complaint cell on required basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to AGE E/M No 1 store yard on daily basis. (g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall be deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Taking up defective cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead from ground, cleaning the pipes free from sedimentation/scaling etc for reusing the serviceable pipes in repairs complete all as specified and directed for the following sizes:-
80 mm bore.
100mm bore.
150mm bore. Note for item Nos 2.01 to 2.03:- Excavation and earth work shall be measured and paid separately.
Re-laying only cast iron pipes obtained from item No.2 above including laying to level or to falls, in trenches or on the ground or on supports complete all as specified and directed for the following sizes:-
80 mm bore.
100mm bore.
150mm bore. Note for item Nos 3.01 to 3.03 :-Lead joints shall be measured and paid separately.
M&L CI pipes with spigot and socket ends centrifugally cast class 'LA' in any length suitable for tyton / lead joints laid in trenches including necessary cut to length to match the existing fitting/pipes, testing and making good disturbed surfaces of roads, path ways etc., while laying the pipe line at site complete all as specified and as directed for the following sizes:-
80mm bore.
100mm bore.
150mm bore. Note for item Nos 4.01 to 4.03 :-Lead joints shall be measured and paid separately.
Taking up or down GI/PVC/PP-R water tubing and connections including cleaning the pipes free from scaling for reusing the same in repairs / alteration or removable to store etc to water pipes and connections complete all as specified and directed for the following sizes:-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
75/80 mm bore.
100/110 mm bore
Re-laying /refixing or rerouting of GI/PVC/PP-R old water tubing and connection in new or old position including fittings with old/new bends, elbows, socket nipples, tapers, and reducers etc as per site requirement (on floors, walls and ceilings) complete all as specified and directed.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
75/80 mm bore.
100/110 mm bore
Supply, lay and fixing steel water tubes, medium grade, ISI marked, galvanised with all fitting laid in trenches complete all as specified and directed for following bore of pipes :-
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
80 mm bore. Note for item Nos 7.01 to 7.05:- Excavation and earth work shall be measured and paid separately.
Supply, laying and testing of Polypropylene random copolymer (PP-R) (PN-16/SDR 7.4)-3 Layers pipes, UV stablised and antimicrobial welded having thermal stability with and including all PP-R plain & brass threaded polypropylene random fittings fixed such as bends, Elbow, Tee, Short Length, Socket, Union, Check Nuts, Nipples etc. (Females/Males as required), suitable for hot cold water supply line including making good disturbed surfaces/cutting chassis in CM 1:3, laid in trenches and including testing complete all as per manufacture’s instruction and all as specified and directed for the following outer dia of pipes:- Make:- SFMC/SUPREME/FINOLEX/KPT
20 mm bore (OD)
25 mm bore (OD)
40 mm bore (OD)
50 mm bore (OD)
75 mm bore (OD)
110 mm bore (OD) Note for item Nos 8.01 to 8.06 :- Excavation and Earth work shall be measured saperately.
Supply only GI fittings 20 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:-
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Elbow
All as per item No 9 here-in-before but for 25 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Nipple 100mm Long
Elbow
Reducer elbow 25mm x 20mm
All as per item No 9 here-in-before but for 40 mm bore.
Union
All equal Tee
Socket
Nipple 75mm Long
Elbow
Reducer elbow 40mm x 25mm
All as per item No 9 here-in-before but for 50 mm bore.
Union
All equal Tee
Socket
Elbow
All as per item No 9 here-in-before but for 80 mm bore.
Union
All equal Tee
Socket
Elbow
S&F CI non raising type sluice valve both ends flanged with CI body, ISI marked, IS 14846 -2000 type, pressure PN 1.6 including jointing materials such as rubber gasket, nuts and bolts, washers,SS spindle, operating hand wheel, etc Complete including replacement of unserviceable sluice valves of any type complete all as specified and directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
S&F Mechanical Joint Collar double ended flanged ISI embossed pressure 1.6 including jointing such as rubber gasket, nuts and bolts, washers materials etc complete including replacement of unserviceable sluice valves of any type complete all as specified and directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
300 mm bore.
S&F DI socket ISI embossed pressure 1.6 including jointing such as rubber gasket, etc complete including replacement of unserviceable socket of any type complete all as specified and directed for the following sizes:-
100 mm bore.
150 mm bore.
200 mm bore.
300 mm Bore
S&F gun metal gate valve, ISI embossed, conforming to is 781-1984, connected with iron wheel head, screwed at both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and directed for the following sizes:-
20 mm bore.
25 mm bore.
40 mm bore.
59 mm bore.
S&F PP-R Gate valves (brass insert), with iron wheel head, screwed both ends for PP-R Pipes and fixed in repair for following bore of pipes :- Make:- SFMC/SUPREME/FINOLEX/KPT
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
Supply only PP-R Pipe fittings 20mm bore, ISI marked, smooth finished and make embosed on fittingsin repairs complete all as specified and directed for the following fittings:- Make:- SFMC/SUPREME/FINOLEX/KPT
All equal Tee
Socket
Elbow
All as per item No 19 here-in-before but for 25 mm bore.
All equal Tee
Socket
Elbow
All as per item No 19 here-in-before but for 40 mm bore.
All equal Tee
Socket
Elbow
All as per item No 19 here-in-before but for 63 mm bore.
All equal Tee
Socket
Elbow
All as per item No 19 here-in-before but for 110 mm bore.
All equal Tee
Socket
Elbow
S&F Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore double acting (DS2) heavy duty including providing jointing material such as rubber fibre board gasket, suitable size bolts and nuts and washers, necessary suports, rasing DI pipe 100 mm dia double side and not less than 1.20 Mtr length Including taking down old unserviceable Air release valve complete all as specified and as directed by Engr-in-charge. Note :- CI/DI specials required at site shall be measured and paid separately.
S&F Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 150 mm dia bore double acting (DS2) heavy duty including providing jointing material such as rubber fibre board gasket, suitable size bolts and nuts and washers, necessary suports, rasing DI pipe 150 mm dia double side and not less than 1.20 Mtr length Including taking down old unserviceable Air release valve complete all as specified and as directed by Engr-in-charge. Note :- CI/DI specials required at site shall be measured and paid separately.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of pipe lines, valve chambers, man holes etc including forming bottom surface to required level and gradient and getting out in hard /dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Removing excavated soil to a distance not exceeding 59m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L cutting of road up to a size not exc 1.5m wide and not exc 1.5m depth for laying of water pipe lines making good the distrubed surfaces so as to match with existing finishing with PCC 1:2:4 type B1 , cement motor in CM 1:2 complete all as specified and directed
Burning out lead joints of the existing CI mains in position including removing old lead carefully without demaging the pipes etc complete all as specified and as directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore. Note:- Exavation and earth work shall be measured and paid seperately under the relevent BOQ item.
M&L for lead joint for CI pipes including spun yarn etc for spigot & socket pipes and fitiings complete all as specified and as directed for the following sizes:-
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
M&L Rubber Gasket joints (Tyton joints) including rubber ring suitable for spigot and socket DI pipe and fittings complete all as specified and as directed for the following sizes:-
150 mm bore.
200mm bore. Note for item Nos 32.01 & 32.02 :- Excavation and earth work shall be measured and paid separately.
S&F ductile iron pressure pipes 200 mm bore, class K9, centrifugally cast with spigot and socket ends conforming to IS 8329/2000 with cement mortar lining inside the pipes and outside zinc coating suitable for push-on-joint including (rubber gasket D jointing) in any length as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm bore for inserting branch connections etc including taking down old existing one complete all as specified and directed :- Notes:- (a) DI pipe shall be laid in trenches at a depth of 1.0 to 1.5 m below the existing GL (b) DI specials will be measured and paid separately. (c) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment. (d) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
All as per Item No.33 here in beore but 150 mm ductile iron pressure pipe
All as per Item No.33 here in beore but 100 mm ductile iron pressure pipe Notes for 33 to 35 :- (a) DI pipe shall be laid in trenches at a depth of 1.0 to 1.5 m below the existing GL (b) DI specials will be measured and paid separately. (c) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment. (d) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution.
M&L for Construction of brick masonry valve chamber of size 1000 x 1000 x 1000 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 159 mm thick, 159 mm wide off sets allround over 100 mm thick hard core, brick masonry walls built in CM 1:6, 59 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 159mm below GL externally and top of floor including excavation, earth work in hard/dense soil, 5 mm thick MS sheet cover fixed on 59 mm x 59 mm x 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of red oxide primer including disposal of surplus soil to a distance not exceeding 59 m etc complete all as specified and directed.
Disconnecting the delivery pipe line and electric connections of submersible pump set of 7.5 HP / 5 HP and removing it from its original position alongwith pipes and fittings carefully including chain pulley with tripod and transporting the same to the work shop situated within the city limits for repair and lowering including all pipes and fittings by means of chain pulley and tripad including connecting up of water and electric connections, testing and commissioning complete all as specified and directed. Notes:- (i) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to work shop and back are deemed to be included in unit rate quoted. (ii) Labour element is deemed to be included in unit rate quoted. (iii) Replacement of worn out parts and rewinding will be measured and paid separetely.
M&L for rewinding of the submersible motor with PVC insulated conductor with super enamelled copper conductor, ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly for submersible motor of 7.5 HP capacity including taking down old unserviceable existing copper winding complete all as specified and directed.
All as per item No 38 here-in-before but for the submersible motor 5 HP capacity.
Supply only the following spares for repairs of submersible pump set of 7.5 HP capacity complete all as specified and directed.
Gun metal impellar
Stage casing
Stage casing bush (LB)
SS sleeves
Pump shaft
Pump coupling
Discharge outlet bush LB
Discharge outlet SS sleeves
Supply only the following spares for repairs of submersible pump set of 5 HP capacity complete all as specified and directed.
Motor bearing bush (LB) 04 Nos set
Thurst bearing set
NRV body
Section bush
Middle bush LB
Middle SS sleeve
Rotor (RE) work
Opening Mono block pump set 5 HP capacity for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered including cleaning, replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including machining etc and testing the both after refixing and commissioning for satisfactory operatrion on its full load complete all as specified and directed.
M&L for rewinding of the mono block pump set 5 HP capacity with PVC insulated conductor with super enamelled copper conductor ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old unserviceable existing copper winding complete all as specified and directed.
Supply only the following spares for repairs of Mono block pump set of 5 HP capacity:-
Ball bearing
Blind bush Gun metal
Gland rope nut
Terminal
Opening Mono block pump set 7.5/10 HP capacity for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered including cleaning, replacing the minor items like packing bolts, nuts washers and MS clamps etc and applying one coat of approved hammertene spray paint on exposed steel surfaces, making the pump and motor fully serviceable including machining etc and testing the both after refixing and commissioning for satisfactory operatrion on its full load complete all as specified and directed.
M&L for rewinding of the mono block pump set 7.5/10 HP capacity with PVC insulated conductor with super enamelled copper conductor ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old unserviceable existing copper winding complete all as specified and directed.
Supply only the following spares for repairs of Mono block pump set of 7.5/10 HP capacity:-
Ball bearing
Impellers
PCV fan
Gland rope
Gland rope flang set
S&F DOL starter 3 phase 415 Volts, 7.5 HP capacity rating 14 Amps, relay range 9 to 14 Amps, MK-1, including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed.
S&F submersible pump controller stater in sheet metal enclosure 3 phase 415 Volts, 5 HP capacity rating 32 Amps, relay range 20-32 Amps, Type MF -G3 $ including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed.
S&F in repairs CI foot valve leather sheet type / flange type suitable for 80 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
S&F in repairs CI foot valve leather sheet type / flange type suitable for 100 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
S&F connecting and testing in repairs of non return valve of size 80 mm dia ISI marked , as per IS 5312 both ends flanged CI body with check nuts including jointing material complete all as specified and directed by Engr-in-charge.
S&F connecting and testing in repairs of non return valve of size 100 mm dia ISI marked , as per IS 5312 both ends flanged CI body with check nuts including jointing material complete all as specified and directed by Engr-in-charge.
Supply and lay submersible copper conductor cable 1100 volts grade PVC insulated, flexible, PVC sheathed with multistranded copper conductor of size 3 core 6 Sq mm cutting to required length connecting with necessary end ferrules / water proof joints including removing the existing unserviceable cable complete all as specified and directed
M&L Flushing of existing borewells of size 150 mm dia, 150 Mtrs depth with drilling compressor including surging and flushing the bore at a pressure of 7 Kg / Sq cm complete with compressed air and flushing the sand, mud etc from the bore well till discharge of the fresh water, including testing of water samples for chemical and bacteriological tests and yield testing for 8 hours complete all as specified and directed .
S&F single phase preventor, SPPR type 360/380/415 volts suitable upto 7.5 HP pump including connecting up of wire / cable testing complete including removing the existing unserviceable one all as specified and directed. Make:-L&T Cat Part No CS81809OOOO or equivalent make in IndioAsian/Leagrand/ HPL as approved by GE.
Supply only free chlorine testing kit paper strips (Colome metirc TMG) for detection levels (0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.2, 1.5, 2.0, 4.0, 6.0 ppm (Mgle) test time 40 seconds having each bottle of 50 test strips complete all as specified and directed.
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor type front openable type, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6, type C2 using 40 mm graded stone aggregate, 45 CM below ground level and 15 Cm above ground level including taking down old existing one and consisting the folowing provisions:- (a) MCCB 63 Amp 25 KA 4 pole -1 No (b) DOL starter Heavy duty 7.5 HP with relay 9-14 Amp - 1No (c) Single phase preventor -1No (d) Pump ON and Supply ON indicator- 1 Set (e) Phase reversal protection for protecting motor from reverse running.
Supply only TCCA 90% Chlorine (Trichloroisocyanuric Acid), effective content of chlorine % : ≥ 90, Content of water % : ≤ 0.5, PH Value of 1% Solution: 2.7 to 3.3, Granular Chlorine/Tablet in packing of 50 kg complete all as specified and directed.
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping /cleaning complete all as directed at Napiers line
Supply only Water treatment chemical calcium hypo Chloride 65%-70% chlorine content (calcium based granular disinfectant for water treatment, packed in 45 kg drum complete all as specified and directed.
Taking down old unserviceable HDPE Pipe and High density polyethylene pipes (HDPE) of pressure rating 20 kgf/cm2 including socket for fixing with pump in borewell of sizeof size 50 mm complete all as specified and directed by Engr-in-Charge
Taking down old unserviceable HDPE Pipe and High density polyethylene pipes (HDPE) of pressure rating 20 kgf/cm2 including socket for fixing with pump in borewell of size 40 mm complete all as specified and directed by Engr-in-Charge
Supply and laying pipes ERW steel inlcuding specials, nominal dia 200mm as per IS 3589 (1981) 6.00mm thick and including cutting work, welding work and taking down of unserviceable ERW/CI pipe complete all as specified and directed by Engr-in-charge.
M&L for GI pipe heavy grade 50mm dia, cut into 3.0 mtr length including providing of threading on both sides and lowering into the existing bore well along with existing GI pipe for increasing the length of the borewell pipe as in repairs complete all as specified and directed.
Reboreing/re-Drilling of existing borewell up to 350 mm dia, from the existing depth, at any type of strata by mud flash rotating equipment, from the Existing depth to 100 Meters . Notes:- (i) Water injection charges if required (ii) Transport Charges (iii) Vehicle settlings & Flishing charges (iv) Expendable stores like cotton waste / cleaning materials (v) Labour element should be included in unit rate quoted.
All as per item No 66 here in before but 100 Mtr to 200 Meters
M&L for measuring exact depth of borewell by lowering 1/4" dia wire rope with its rolling stand all as specified and directed by Engr-in-charge.
M&L for cleaning of existing column pipes (3 Mtr length ) duly scraping, cleaning and painting complete through anti corrosive black bituminous paint all as per directed by Engr-in-Charge.
S&F Steel wire rope anti corrosion (SS) of cage 6mm thickness fror fixing submersible pumps including necessary nut, bolt & clamps all as specified and directed by Engr-in-Charge.
bethelenterprises
L and S ENTERPRISES
M Laxmana Rao and Sons
STANDARD AGENCIES
Srinivasa Consructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .