Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹19.4 L+₹59,100 (3.15%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹20.5 L+₹1.7 L (8.98%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹25.0 L
EMD Value
₹49,920
Closing Date
3 Oct 2024, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
REPAIR REPLACEMENT OF OH TANKS, WATER PROOFING TREATMENT RCC ROOFED SLAB INCL ALLIED WORK AT AFS CHAKERI KANPUR
2024_MES_671739_1
GE (AF) BR/CHK/T-34 OF 2024-25 8969/E8
Open Tender
Civil Works
Item Rate
270 days
GE(AF) B/R Chakeri Kanpur
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹49,920
Yes
2 Dec 2024
5 Sept 2024
10 Oct 2024
5 Sept 2024
3 Oct 2024
19 Sept 2024
Amount
S&F in repairs of float valve of PTMT with epoxy coated Aluminum rod & high density plastic ball screwed for iron pipe and fixed weight-142 gm for 15mm dia pipe complete all as specified and directed.
All as per sl item No 1 but 20 mm weight 210 gm bore pipe complete all as specified and directed .
All as per sl item No 1 but 25 mm weight 455 gm bore pipe complete all as specified and directed .
S&F 45cm long PVC connection with two no PTMT nut and rubber washers suitable for 15mm bore GI Pipe in replacement of existing one complete all as specified and directed .
S&F 60cm long PVC connection with two no PTMT nut and rubber washers suitable for 15mm bore GI Pipe in replacement of existing one complete all as specified and directed .
S&F in repairs of of Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-110gms complete all as specified and directed .
S&F in repairs of PVC PTMT bib tap 15mm dia pipe with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule complete with check nut 15mm bore complete all as specified and directed .
S&F in repairs of PVC PTMT stop cock 15mm dia pipe with crutch or butterfly handle screwed iron pipe or for brass ferrule complete with check nuts 15mm complete all as specified and directed .
S & F in repairs PVC waste pipe 32mm dia, 90 cm long for WHB/Sink/urinal with cup, fixed in repairs complete.
S&F in repairs PTMT Health faucet incl flexible pipe of 1.5m length and fixing brackets and fixed as per manufacturers instruction
S&F in repairs of water closet seat, white closed pattern with flat bottom & cover & mild steel chromium plated hinging device complete all as specified and directed .
Draining out water from existing PVC water storage tank exc 500 ltr and not exc 1000 ltr capacity and cleaning silt deposited therein, washing out with soap water or surf including taking down connection and refixing complete all as specified and directed .
Draining out water from existing PVC water storage tank exc 250 ltr and not exc 500 ltr capacity and cleaning silt deposited therein, washing out with soap water or surf including taking down connection and refixing complete all as specified and directed .
S&F in repairs of PVC ( SWR) pipes single socketed in any length with rubber ring joints fixed to wall ( 110mm bore) including flat iron clamp for proper fixing complete all as specified and directed .
All as per sl item No 14 but refixing only including taking down existing old pipe complete all as specified and directed .
S&F in repairs of PVC (SWR) bends 110mm dia complete all as specified and directed .
Taking up or down PPR/GI tubing 15 mm bore pipe complete all as specified and directed .
Taking up or down PPR/GI tubing 20 mm bore pipe complete all as specified and directed .
S&F of 15mm bore GI tubing medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed .
All as per sl item No 19 but 20mm dia complete all as specified and directed .
S&F in repairs of PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connection to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make complete all as specified and directed .
S&F in repairs of white colour triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and jointed in position all as specified in SSR Part-I (500 ltr capacity) including disconnecting existing tank and providing all necessary fittings for connecting with pipe line, metal lockable cover complete all as specified and directed .
S&F in repairs of white colour triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and jointed in position all as specified in SSR Part-I (1000 ltr capacity) including disconnecting existing tank and providing all necessary fittings for connecting with pipe line, metal lockable cover complete all as specified and directed .
Taking down and refixing of old steel tubing connection in new or old position (wall etc) including cleaning for refixing bore of pipe 15mm dia including connected GI fittings complete all as specified and directed .
All as per Srl Item No 24 above but 20mm bore of pipe including connected GI fittings complete all as specified and directed .
All as per Srl Item No 24 above but 25mm bore of pipe including connected GI fittings complete all as specified and directed .
S&F in repairs of small fittings galvanised iron medium grade such as socket, elbow, reducer, nipple, tee, union, tank nipple, tank connection and other GI fittings etc of any size for 15mm bore GI (ISI marked) complete all as specified and directed .
All as per Srl Item No 27 above but 20mm GI fitting (ISI marked) complete all as specified and directed .
All as per Srl Item No 27 above but 25 mm GI fitting (ISI marked) complete all as specified and directed .
S&F in repairs of CP pillar tap 15mm bore dia cast copper alloy with cap capston chromium plated screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly buts screwed for iron pipe complete all as specified and directed .
S&F in repairs of for bib taps 15mm bore (for iron pipe) cast copper alloy with fancy type chromium plated butter fly handle screwed down including fixed in repairs of complete all as specified and directed .
S&F in repairs of for angle stop valves 15mm bore (for iron pipe) fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends including fixed in repairs of complete all as specified and directed .
S&F in repairs of for PVC tank cover as in PVC over head tank including cover to be fixed in frame with threading system. The frame to be fixed with tank by 4 nos PVC nut bolts and arolite complete all as specified and directed . Note: The cover to be provided for 500/1000 ltrs capacity.
S&F in repairs of CP Health Faucet with 1.5mtr long SS tube and hook complete all as specified and directed .
Dismantling plain or corrugated steel sheeting, any gauge or thickness at any position or similar pattern of roof covering complete all as specified and directed.
S & F pre-painted galvalume aluminum zinc coating 150gsm, ISI Marked GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F pre-painted galvalume aluminum zinc coating 150gsm, ISI Marked GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge to match the existing roof coverings, fixed with self tapping screws complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
M&L Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including old and unserviceable any type of treatment already done and removal the demolished material from the site out of MoD complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregate as in roof padding for providing required slope finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for screed bedding 15 mm thick plaster in CM 1:4 on roof finished even and fair on roof mixed with water proofing compound up to four stories bldgs complete all as specified and directed. Note : WPC shall be measured and paid separately as "supply only".
S&F APP based polymeric water proofing membrane minimum weighing 3 Kg/sqm and 3mm thick reinforced with polyster non wove fabric ( weight not less than 150 gms/sqm) by torch application laid over and including bituminous primer @0.50 kg per sqm including cleaning of surface complete all as per approved manufacturer's instructions. Note The water proofing treatment shall be got carried out by manufacturer or their auth applicators complete all as specified.
M&L cement concrete tiles 30cmx30cmx22mm thick laid over and including 15mm thick screed in cement mortar 1:6 and jointed grouted and pointed in CM 1:3 complete all as specified and directed.
Supply only liquid water proofing compound.
M&L for reinforced elastromeric PU based liquid water proofing compound membrane with resilient acrylic polymers having sun reflectivity Index (SRI) of 105 as approved by GE on top of roof surface in three coats @ 10.76 ltr /10 Sqm. One coat of self priming of elastomeric PU based water proofing liquid (dilution with water in the ratio of 3 :1 i.e. 3 part of water proofing liquid and one part of water), laying of Geo Txtile Fleece and two coats of undiluted elastomeric water proofing liquid. The dry film thickness of complete allocation/ system should not be less than 600 micron. The treatment shall be carried out through authorised representative of manufacturer and application shall be done by mechanical sprayers or as directed by GE.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets including grid work complete all as specified and directed.
S&F 16mm thick of size 595 x 595/600 x 600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled tegular ) of Armstrong or equivalent make and model including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping ,main runner and cross runner and to comprise main tee/runner 15 mm x 38mm size (load carring capacity 14 kg /sqm ) spaced at 1200 mm centres securely fixed to the structural sofit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm module , cut sub cross tee/runner 600mm require independent support ,wall angle of size 19mm x 19mm secured to the periphery of the wall at 450 mm maximum centre the above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350mm , complete all as specified and directed
Supply and fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and pattern having moister content less than 2%, humidity resistant of 99%, NRCO.50 to 0.75 as per IS 8225:1987, noncombustible as per BS 476 (part 4) - 1970 and light reflectance of 85% minimum to be laid in true horizental level suspended on inter-locking metal T-Grid of hot dipped galvanised ireon section of 0.33mm thick (galvanised @120gm/Sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross T of size 15 x 32 mm of length 1200mm and secondary intermediate corss T of size 15 x 32 mm of length 600mm to from grid module of size 600x 600 mm suspended from ceiling using galvanised mild steel items (galvanised @ 80gm/Sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifiection, drawing and as per directed of Engineer-in-Chagre.
M&L for light shade Vitrified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. laid over and including 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of old tiles and removing the same from site, complete all as specified and directed.
M&L for light shade Vitrified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in dado/skirting etc. and including 10 mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles including dismantling of old tiles and removing the same from site, complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement including taking down cement plaster or concrete, brick surface and raking out joints, hacking for key scrubbing down with water to receive plaster complete all as specified and directed .
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement including taking down cement plaster or concrete, brick surface and raking out joints, hacking for key scrubbing down with water to receive plaster complete all as specified and directed .
M&L for rendering 5mm thick in CM (1:3) on fair faces of ceiling surfaces finished even & smooth without using extra cement including taking down cement plaster or concrete, brick surface and raking out joints hacking for key scrubbing down with water to receive plaster complete all as specified and directed .
M & L for preparation of new undecorated surfaces of walls and applying two coat of Oil Bound Distemper over a coat of primer and 1mm thick wall care putty, all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of primer, complete all as specified and directed .
M&L for preparation of new undecorated surfaces of ceiling and applying three coats of white wash all as specified and directed.
Notes :- 1 (i) The unit rates quoted for above items are also includes to provide the following workers to execute the above works as well as to attend the complaint assigned by concerned JE. (ii) Contractor is also bound to deploy more man power if required to any of the item to execute the above work. 2. The labours as required to execute the above items shall be supervise by a supervisor of the contractor who will manage all the working labours till the time from 8.30 AM to 5.30 PM. 3. The complaint shall be attended on the same day failing which a recovery of Rs. 500/- per day per complaint shall be made from the contractor's dues.
continentalconstructionco. (BID ID -3115550)
smc system & services (BID ID -3116226)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .