| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.7 LAccepted-AOC | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹31.3 L+₹11,294 (0.36%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹33.9 L+₹2.7 L (8.65%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹34.5 L+₹3.3 L (10.6%)Rejected-Finance 104 INDIRA MARKET NEAR MALAI MANDIR SECTOR 07 RK PURAM NEW DELHI PIN 110022 | NEW DELHI | NEW DELHI | DELHI | 110022 | 4 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | QUALITY CONSTRUCTIONS CO L3 | M/S KAUSHIK CONSTRUCTION L2 | KUMAR ENTERPRISES L1 | Mohit Infratech L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid dry or laid dry and pointed in any mortar complete all as specified and directed.. | 6 | 10 Sqm | 500 ₹3,000 | 400 ₹2,400 | 80 ₹480 Lowest | 500 ₹3,000 |
| 2.00 | Demolition of cement conrete of any description and in any position not otherwise specially provided etc. all as specified and directed. | 105 | Cum | 200 ₹21,000 | 400 ₹42,000 | 128 ₹13,440 Lowest | 500 ₹52,500 |
| 3.00 | Excavation in trenches not exc 1.5 mtrs depth and not exc 1.5 mtrs wide for foundation, man hole etc, not exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. | 80 | Cum | 300 ₹24,000 | 120 ₹9,600 | 110 ₹8,800 Lowest | 200 ₹16,000 |
| 4.00 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling and mass concrete etc complete all as specified & directed. | 20 | Cum | 4,000 ₹80,000 | 3,500 ₹70,000 | 4,200 ₹84,000 | 2,500 ₹50,000 Lowest |
| 5.00 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in surface channel, subbase of drain complete all as specified and directed. | 8 | Cum | 4,800 ₹38,400 | 5,000 ₹40,000 | 4,500 ₹36,000 | 3,000 ₹24,000 Lowest |
| 6.00 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping and benching of drain etc. all as specified and directed. | 3 | Cum | 6,000 ₹18,000 | 6,000 ₹18,000 | 3,800 ₹11,400 Lowest | 4,000 ₹12,000 |
| 7.00 | M&L for extra for forming fair finished drain or channel 45cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc | 250 | RM | 50 ₹12,500 Lowest | 100 ₹25,000 | 82 ₹20,500 | 100 ₹25,000 |
| 8.00 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25cm in soft/loose soil all as specified. | 5 | Cum | 100 ₹500 | 500 ₹2,500 | 60 ₹300 Lowest | 225 ₹1,125 |
| 9.00 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed | 75 | Cum | 150 ₹11,250 | 500 ₹37,500 | 65 ₹4,875 Lowest | 500 ₹37,500 |
| 10.00 | M&L for brick work using fly ash brick conforming to IS-12894 2002, old size class designation 7.5, straight or curved on plan, exc. 6.0 m mean radius modular bricks in CM (1:6) all as specified and directed. | 50 | Cum | 5,000 ₹2,50,000 | 5,500 ₹2,75,000 | 5,500 ₹2,75,000 | 4,000 ₹2,00,000 Lowest |
Tender Value
₹38.8 L
EMD Value
₹77,644
Closing Date
11 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
SPL REPAIR TO BLDG NO T-11 AT CENTRAL COMD EQUITATION TRAINING NODE(CCETN) UNDER GE (EAST) LUCKNOW.
2025_MES_726210_1
CWE/LKO/E/T-39 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE East LUCKNOW
₹77,644
Yes
6 Jan 2026
14 Aug 2025
18 Sept 2025
14 Aug 2025
11 Sept 2025
28 Aug 2025
14 Aug 2025 - 28 Aug 2025
Amount
Dismantling bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid dry or laid dry and pointed in any mortar complete all as specified and directed..
Demolition of cement conrete of any description and in any position not otherwise specially provided etc. all as specified and directed.
Excavation in trenches not exc 1.5 mtrs depth and not exc 1.5 mtrs wide for foundation, man hole etc, not exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling and mass concrete etc complete all as specified & directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in surface channel, subbase of drain complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping and benching of drain etc. all as specified and directed.
M&L for extra for forming fair finished drain or channel 45cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25cm in soft/loose soil all as specified.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
M&L for brick work using fly ash brick conforming to IS-12894 2002, old size class designation 7.5, straight or curved on plan, exc. 6.0 m mean radius modular bricks in CM (1:6) all as specified and directed.
M&L for PCC 1:2:4 type B-2(using 40 mm graded stone aggregate) as in surface channel of drain complete all as specified and directed.
Taking down cement plaster on brick walls / ceiling incl. raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed..
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces finished surfaces fair even and smooth (w/o using extra cement) in CM 1:4 incl necessary scafolding,staging upto 9.5m height etc complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces finished surfaces fair even and smooth (w/o using extra cement) in CM 1:6 complete all as specified and directed.
M&L preparation of new surfaces of wall and applying two coat of white wash on surfaces of wall all as specified.
M&L preparation of new surfaces of wall and applying two coat of cement bases paint over one coat of primer on surfaces of wall all as specified.
M&L preparation of old surfaces of of wall and applying two coat of oil distemper (OBD) on surfaces of wall all as specified.
M&L for 50 mm thick PCC 1:3:6 type B-2 ( using 20 mm graded crushed stone aggregate) as in plinth protection surface finished fair and even without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:12 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for 100mm thick PCC 1:2:4 type B2 (40mm graded stone aggr) as in floor laid in alternate panels finished even and smooth without using extra cement complete all as specified and directed.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each, complete, all as specified & directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) and area not exc 1.5 sqm each, complete, all as specified & directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire, staples all as specified.
S&F for framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other coverings, doors etc should be prepared for hanging or sliding with and including either hooks or hinges or steel hanging door fitting (exclusive of steel hanging door fittings and other coverings, running rails and guides and hanging also fastening and fixing complete quality conforming to FE-410W(gde E-250) quality B complete all as specified & directed.
S&F for hard drawn steel wire fabric n.exc 4kg/sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt fixed with tinned tacks of wire staples etc complete all as specified & directed.
S&F aluminium powder coated frame/chowkat of aluminium door section of 100x44x1.60to1.8 mm thick fixed with rawal plug and screw or wire expansion hold fasteners complete all as specified and as directed.
Providing and fixing powder coated aluminium partly glazed and partly panelled door shutter side hung type using 1.50mm thick standered door section having size of styles, top rails 83x44mm x 1.6 to 1.8mm thick where as bottom rails will be made up of 100x44mm Make: Jindal/Hindalico including necessary joining cleats glazing clips, rubber packing, anodized aluminium snap beading screws, anodized aluminium fittings such as 100mm long 3 No. aluminium hinges B-21 ,type 01 No. aluminium tower bolt 200mm long and one no mortise lock 100mm size 4 levers (vertical type) and 01 No 300mm size long aluminium sliding bolt and 02 No fancey type fiber glass 150mm dia circular handle shall be provided to each door and glazing of top panel shall be made of 5.50 thick sheet glass make - Modi/ Saint gobin and pannelling shall be provided with 12mm thick exterior grade pre laiminated partical board with both side choice laminations, complete all as specified & directed.
S&F in repairs aluminium body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg. and fixed. complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S&F mild steel section such as Roof trusses (framed), trussed,purlins, crane antries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to IS 1161-1979 Fe-450(Gde E-250)complete all as specified and as directed.
M&L for preparation of new surfaces of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified.
S&F of butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified & directed.
S&F of butt hinges 100mm size extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed, type B-21 complete all as specified & directed.
S&F of 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified & directed.
S&F of 125 mm size aluminium alloy handles, fabricated type, extruded section complete all as specified & directed.
S&F in repairs false ceiling with 4mm thick E-board Everest make white prepainted set embosed reinforced designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600x600mm having 24mm wide T-section runner made of 0.33mm GI sheet and angle made of 0.45mm, GI sheet suspected with 4mm dia GI wire including two coat of plastic emulsion paint over one coat primer complete all as specified. Note. All exposed surface of grid work shall be powder coated white.
S&F in repairs coloured pre-painted GALVALUME aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strngth of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws including necessary washers etc all as per manufactures instruction. complete all as specified & directed.
Ditto- all as per item No.37 above but plain roofing sheet as in ridge all as manufacturers instruction and complete all as specified & directed.
M&L for preparation of old surfaces of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide complete all as specified.
Taking down carefully copper/aluminium point wiring ( light, fan, socket , bell or power) complete including all electrical fittings & fixtures(DBs,submain,cables etc) all as specified and directed by Engineer-in-charge.
Taking down carefully Ceiling fan/wall fan/Exhaust fan complete including all electrical fittings & fixtures etc and refixing after spray painting of 2 coats all as specified and directed by Engineer-in-charge.
Taking down carefully any Light fittings/fixtures any size complete including all (electrical fittings & fixtures etc) all as specified and directed by Engineer-in-charge.
Material and Labour for point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed multi stranded copper conductor single core cable 1100 volts grade in and including PVC conduit with accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed. Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified.
All as per Item No 43 point wiring with 2.5 sqmm hereinbefore but for One 5 A socket outlet on independent Board all as specified and directed.
All as per Item No 4 hereinbefore but for One 5 A socket outlet on same Board all as specified and directed.
All as per Item No 4 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
Supply and fix frame plate with match cover twelve module all as specified and directed.
Supply and fix frame plate with match cover eight module all as specified and directed.
Supply and fix frame plate with match cover six module all as specified and directed.
All as per item No.49 above but three module all as specified and directed.
Supply and fix terminal box suitable twelve modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
Supply and fix terminal box suitable eight modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
Supply and fix terminal box suitable six modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
All as item No above but three modular plat of size 100X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module all as specified. Make:
Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified.
Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified.
Supply and fix in repair of MCB DB SPN 8 way double door type suitable for TP/FP including necessary dummy plate and necessary civil works all as specified and directed.
Supply and fix in repair of MCB DB TPN 4 way double door type suitable for TP/FP including necessary dummy plate and necessary civil works all as specified and directed. Make: Havells Cat No DHDLVDRWAOFO08 or equivalent in Legrand/ L&T
Supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed.
Supply and fix MCB SPN 230V, 32 Amp capacity all as specified and directed.
Supply and fix MCB DP 415V, 40 Amp capacity all as specified and directed.
Supply and fix MCB DP 415V, 63 Amp 16K capacity all as specified and directed
Supply and fix Modular Regulator 230V AC 50 HZ SP two module all as specified.
S&F modular bell push single pole 1 module 6 Amp, 240 volt all as specified. Make: Legrand/Anchor Roma/Havells
S&f call bell , ding dong / musical AC single phase 230 volts all as specified.
S&F Ceiling rose PVC polycarbonate all as specified and directed.
Supply and fixing of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95,
S&F Bulkhead,10 watt LED light fitting complete all as specified & directed.
Supply and fixing in repacement recess mounting LED light fitting 2'x2' luminaire architectural recessed luminaire with CRCA housing and Molded PC diffuser with an unique angular optics for making the illumination easy on eyes for light comfort in office areas with UGR<=19. The luminaire should have a color consistency SDCM< 5, CRI > 80 and choice of CCT: 5700K. Luminaire shall be designed to emit at least 3000 lumens and an efficacy of atleast 120Lm/W and maximum system wattage of 36 Watt, designed for ambient temp 45 deg C. The metallic electronic driver shall have a power factor >0.95, THD <10%, 4KV internal surge protection and the Ripple factor should be <5% to minimise the Flicker and Stroboscopic effect and Fixture should have an operating voltage range of 140-270VAC incl all as specified and directed by engineer in charge. Make- Philips or Eqv to Havells/Bajaj
Supply and fix in replacement 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75k Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as perIEC 61000-4-5 all as specified and directed by engineer in charge. Make- Philips Model No- UrbanedgeD2DBR501 or Eqv to Havells/Bajaj
Supply and fix in replacement of lithium based energy efficient integrated all-in-one solar street light of Min 18 Watt plus/minus 2% ( Min 3000 lm) IP-65 &IK-08,Aluminium pressure die cast, battery capacity min 30Ah@ 12.8V or 256Wh, panel capacity min 75 Wp with duly ,encases lamp with aluminium reflector for better light distribution CRI>70 COLOUR TEMPERATURE 5700-6500K microcontroller basedcharge controller cum driver automatic diming function (first four hour at full brightness and rest of time at lower light level with PIR motion sensor dusk to dawn operation suitable to working temperature -10 to 55 C weight not less than 14-16 kg with adjustable MS clamp suitable for pole wall mounting etc complete as req protection short circuit overload reverse polarity and battery protection firm should provide vital parameter test report from NABL accredited lab and should be made in India with CE and ROHS complaint INCL 6 Mtr of GI Pipe of dia 4 inch and PCC work all as specified and directed by Eng-in-Charge.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Material and Labour for Submain wiring with 4 runs of FRLS grade PVC copper conductor cable 10 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 25 mm dia with all fittings all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) incl remote operation all as specified and directed. Note:- Down rods of suitable length( 4feet,5 feet or 6 feet) is incl in the item rates and no extra payment will be done to the contractor for the same.
Supply and fix single pole and neutral PVC enclosure Modular with a two pin and earth plug and socket complete with one 20 amps SPN MCB all as specified and directed
Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 20 cm girth and matching wall color.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core all as specified and directed by Eng-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated material to a distanc e not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of cables complete all as specified and directed.
Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
Supply and fixing GI Pipe of 50mm dia for protection of cables all as per specified and directed by the Engr-in-Charge.
M&L for LT Panel factory made DB made out of 2mm thick MS CRCA sheet with powder coated finish complete with IP 43 protection and having 100amp MCCB 4Pole with 4 Nos copper bus bar having size 200Amp complete. Panel size 60 cm in height, 450mm in width and 250mm in depth comp-lete having 3 Nos of digital indicator lamp with 01 Nos of digital Amp meter with 3 Nos of CT of rating 100/5Amp and 01 Nos of digital voltmeter suitable for 415V, 100 Amp capacity complete complete fixed on wall with suitable fastner-04 Nos and angle iron frame incl connection of incoming and outgoing electric supply complete all as specified &directed.
Material and labour Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion all as specified and directed.
Repair/Replacement of PVC air freshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:-
Supply and fixing Exhaust fan Steel body heavy duty body 450 mm sweep working on single phase supply incl. all accessories including electrical connection with required wire complete all as specified and directed.
M/S KAUSHIK CONSTRUCTION (BID ID -3416137)
QUALITY CONSTRUCTIONS CO (BID ID -3416103)
Mohit Infratech (BID ID -3422404)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .