Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.7 L+₹1.4 L (7.13%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹21.8 L+₹1.5 L (7.31%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹21.9 L+₹1.6 L (8.00%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹22.2 L+₹1.9 L (9.54%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
9 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8363/E8
2021_MES_447285_1
8363/E8
Open Tender
Civil Works
Item Rate
30 days
VASCO
Class E Category b i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹38,000
Yes
26 Jun 2021
1 Jun 2021
11 Jun 2021
1 Jun 2021
9 Jun 2021
3 Jun 2021
1 Jun 2021 - 3 Jun 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft disintegrated rock
M&L for Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm. Make : Mehtab/National
M&L for cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) for foundation of pole / stay including form work etc.
M&L for cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) in coping of poles studs including form work etc complete all as specified
Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed by Engineer-in-Charge. Note :- (a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), new nut, bolt and washers of required size / description are deemed to include in this rate.
All as per item No.9.00 here in before but of size 4 core 25 sqmm
All as per item No.9.00 here in before but of size 3 1/2 core 35 sqmm
All as per item No.9.00 here in before but of size 3 1/2 core 50 sqmm
All as per item No.9.00 here in before but of size 3 1/2 core 70 sqmm
All as per item No.9.00 here in before but of size 3 1/2 core 95 sqmm
All as per item No.9.00 here in before but of size 3 1/2 core 120 sqmm
Material and labour for GI tubing light grade 100 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
Taking down carefully aluminium conductor of any size from LT OH Lines after unbinding from insulators for replacement of multi jointed / undersize conductors.
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and outgoing cables complete all as specified and directed.
Restringing and restretching aluminium conductor reterived under Item Srl No. 18.00 above including necessary binding with insulators using aluminium binding wire, connections of incoming and outgoing cables complete all as specified and directed.
Re- Stringing only existing LT OH line including dismantling of existing old binding wire complete. Note: (a) Restringing of 2 wires shall be measured as one RM (b) Supply only binding wire shall be measured and paid separately.
Taking down carefully earth wire of any size from LT OH Lines after unbinding from insulators for replacement of GI wire.
M&L for GI wire 4mm dia drawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint.
Taking down/Dismantling insulators carefully any type, any size
M&L for shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
M&L for pin insulators 75 mm height and 90mm dia size porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
M&L for stay assembly using GI stay rod 20mm dia complete with stay plate mild steel of size 300x300x6.00mm thick, stay bow complete all as specified and shown in Electrical Plate No 1. (Necessary earth work, stay wire, loop insulator, clamps and PCC shall be measured and paid seperately) complete all as specified and directed.
M&L for Galvanised stay wire of size 7/4mm all as specified and directed.
M&L for loop type insulator large size porcelain vitirious of size 90 x 140 mm clearence of hole 16mm complete all as specified and directed.
Taking out old concrete poles of 9M long embedded in concrete unto bottom of foundation and M&L for prestresed cement concrete pole 9 mtr long, 102 mm x 172mm at top and 102mm x 279mm at bottom class-10 complete, erected truly in vertical position and painting the poles with synthetic enamel paint upto 1.5 mtr from the coping above the ground level with alternate layer of 30 cm width with black and yellow paint complete all as specified and directed by Engineer-in-Charge. (Earth work and PCC will be measured and paid separately under respective items).
Supply and laying in trenches/on piller GI Pipe 40 mm bore dia medium grade ISI marked including all fitting and accessories, laid in trenches/under road/on wall/under floor or in air for connection of ditch all as complete as per site requirement for watering purpose of earthing. Make: Jindal/Parkash Surya/TATA
S and G Constructions
OM SAI ELECTRICALS
Shree Ram Enterprises
star freeze service
sapna enterprises
Susheel Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .