Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-Finance Accepted being L1 | |
| 2 | L2₹49.7 L+₹6.6 L (15.2%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹50.1 L+₹7.0 L (16.2%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹52.2 L+₹9.1 L (21.1%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L4 | Rejected-Finance Rejected being L4 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
27 Mar 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
REPAIR MAINTENANCE OF DG SETS AMF PANELS CONTROL PANELS AND CONNECTED ALLIED WORKS UNDER GE I RD EAST BANGALORE
2023_MES_583036_1
8355
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I RD East Bangalore
D b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹92,000
Yes
30 Mar 2023
25 Feb 2023
29 Mar 2023
26 Feb 2023
27 Mar 2023
13 Mar 2023
27 Feb 2023 - 7 Mar 2023
Amount
A Check : M&L for monthly Inspection, maintenance and serviceing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed.
Monthly Service :
Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately
Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately
Checking of oil bath air cleaner level
Checking of exhaust system for leakage
Draining of sediment from fuel filter and fuel tank
Cleaning of air cleaner element
Checking engine alternator coupling, mounting bolts and alignment
Tighting all nuts, bolts, in altenator terminal block
Checking of alternator carbon brush and connections in alternator
Checking and tighting of all connection in DC control wiring.
Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately
Checking and recording oil pressure, water and oil temperarute
Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately
Checking throttle linkage
Checking battery for cell test, electrolyte level, gravity and topping up to required level
Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit.
Checking of AMF panel, all electrical connections etc.
Checking of earthing resistance
Cleaning of vegitation around the DG set up to 1.5 mtr area.
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos)
500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2
320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn
320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger
250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell
200 KVA Capacity, Make : Cummins, Model NTA-743-G, Location : MES Sub Stn 'E' type (02 Nos)
180 KVA capacity, Make : Kirloskar, Model AT00036074 , Location : CEMILAC
125 KVA Capacity, Make : Kirlosakar, Model 6R 1080 TA, Location : Pump House 'E' type, CDA bldg
100 KVA Capacity, Make : Kirloskar, Model 6R1080 T, Location : GTRE PMO bldg
75 KVA Capacity, Make : Ashok Layland Model AL4CTIDG3, Location : GTRE MLCP bldg
62.5 KVA Capacity, Make : Kirloskar, Model 4AB225S1, Location : GTRE Wet Canteen, MRS III, CABS near security bldg (03 Nos)
50 KVA Capacity, Make : Cummins, Model- 4BTAA303-G11, Location : CABS near security bldg
50 KVA Capacity, Make : Kirloskar, Model 94AH 162480, Location : GE Office
40 KVA Capacity, Make : Greaves, Model 3G11TAG25, Location : GTRE GTX-7
30 KVA Capacity, Make : Greaves, Model 4PWII-PII-30X, Location : CABS Pump house
B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :-
Repeat the activities of 'Á' Check
Replacment of of lubricant oil. (Note:- Lub Oil are Paid separately.)
Replacing lubricant oil filter eleement with 'O' ring
Replacing fuel filter element
Replacing coolant.
Replacing Governer oil
Notes :
B Check kit, coolent shall and Lubricant oil shall be measured and paid separately under relevent items
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos)
500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2
320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn
320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger
250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell
200 KVA Capacity, Make : Cummins, Model NTA-743-G, Location : MES Sub Stn 'E' type (02 Nos)
180 KVA capacity, Make : Kirloskar, Model AT00036074, Location : CEMILAC
125 KVA Capacity, Make : Kirlosakar, Model 6R 1080 TA, Location : Pump House 'E' type, CDA bldg
100 KVA Capacity, Make : Kirloskar, Model 6R1080 T, Location : GTRE DMO bldg
75 KVA Capacity, Make : Ashok Layland Model AL4CTIDG3, Location : GTRE MLCP bldg
62.5 KVA Capacity, Make : Kirloskar, Model 4AB225S1, Location : GTRE Wet Canteen, MRS III, CABS near security bldg (03 Nos)
50 KVA Capacity, Make : Cummins, Model- 4BTAA303-G11, Location : CABS near security bldg
50 KVA Capacity, Make : Kirloskar, Model 94AH 162480, Location : GE Office
40 KVA Capacity, Make : Greaves, Model 3G11TAG25, Location : GTRE GTX-7
30 KVA Capacity, Make : Greaves, Model 4PWII-PII-30X, Location : CABS Pump house
Supply only B check kit for DG set of following capacities :- Note : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos)
500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2
320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn
320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger
250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell
200 KVA Capacity, Make : Cummins, Model NTA-743-G, Location : MES Sub Stn 'E' type (02 Nos)
180 KVA capacity, Make : Kirloskar, Model AT00036074 , Location : CEMILAC
125 KVA Capacity, Make : Kirlosakar, Model 6R 1080 TA, Location : Pump House 'E' type, CDA bldg
100 KVA Capacity, Make : Kirloskar, Model 6R1080 T, Location : GTRE DMO bldg
75 KVA Capacity, Make : Ashok Layland Model AL4CTIDG3, Location : GTRE MLCP bldg
62.5 KVA Capacity, Make : Kirloskar, Model 4AB225S1, Location : GTRE Wet Canteen, MRS III, CABS near security bldg (03 Nos)
50 KVA Capacity, Make : Cummins, Model- 4BTAA303-G11, Location : CABS near security bldg
50 KVA Capacity, Make : Kirloskar, Model 94AH 162480, Location : GE Office
40 KVA Capacity, Make : Greaves, Model 3G11TAG25, Location : GTRE GTX-7
30 KVA Capacity, Make : Greaves, Model 4PWII-PII-30X, Location : CABS Pump house
Supply only coolent, K cool super plus 50-50 Premix
Supply only Battery water with electrolyte mix
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Material and labour for replacement of unserviceable battery 12 V, 150 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Material and labour for replacement of unserviceable battery 12 V, 90 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Dismaintling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning :
30 / 40 /50 KVA Capacity
62.5/75 KVA Capacity
100 /125 KVA Capacity
180/200/250 KVA Capacity
320 KVA Capacity
500 KVA Capacity
Dismaintling, removing the alternator /dynomo of from the engine of following capacity of DG Sets , opening up over hauling servicing, replcement of carbon brushes with holders, assembling back , refixing and testing for proper function.
30 / 40 /50 KVA Capacity
62.5/75 KVA Capacity
100 /125 KVA Capacity
180/200/250 KVA Capacity
320 KVA Capacity
500 KVA Capacity
Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function :
30 / 40 KVA Capacity
50/ 62.5 KVA Capacity
75/100 /125 KVA Capacity
180/200/250 KVA Capacity
320 KVA Capacity
500 KVA Capacity
Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ serving, replacement of pim spiral, washers, Cup injector,retainer, Cup screwetc assembling calibiration, setting for proper function refixing and testing for:
30 / 40 KVA Capacity
50/ 62.5 KVA Capacity
75/100 /125 KVA Capacity
180/200/250 KVA Capacity
320 KVA Capacity
500 KVA Capacity
Disconnecting all the connections from alternator of DG Set of following Capacity removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing clening all the parts with thinner and varnishing completely with F class varnishing, applaying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed.
30 / 40 KVA Capacity
50/ 62.5 KVA Capacity
75/100 /125 KVA Capacity
180/200/250 KVA Capacity
320 KVA Capacity
500 KVA Capacity
M & L for replacement of defective spare parts of DG Sets of capacity 500 KVA, Make : Cummins, Model KTA-19-G9 including connecting and testing all as specified and directed.
(a) Radiator Hose Pipe Set
(b) Air filter (inner & Outer)
(c ) Water Pump assembly
(d) Turbocharger repair Kit
M & L for replacement of defective spare parts of DG Sets of capacity 320KVA, Make : Cummins, Model KT-1150-G TA including connecting and testing all as specified and directed.
(a) Fuel Pipe
(b) Air filter (inner & Outer)
(c ) V Belt
(d) Water Pump Kit
M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA, Make :Greaves Model TBD2V12MKII including connecting and testing all as specified and directed.
(a) Air filter
(b) V belt
(c) Fuel Pipe
(d) Battery terminals
(e ) Battery Lead (Red & Black)
M & L for replacement of defective spare parts of DG Sets of capacity 250KVA, Make : Kirloskar, Model 6SL8800TA including connecting and testing all as specified and directed.
(a) Air filter inner
(b) Air filter assembly
(c) Batterty Lead
(d) V Belt
(e) Oil Seal
M & L for replacement of defective spare parts of DG Sets of capacity 200 KVA, Make : Cummins, Model NTA-743-G including connecting and testing all as specified and directed.
(a) Air filter Inner
(b) Turbo charger repair Kit
(c )Water Pump Assembly
M & L for replacement of defective spare parts of DG Sets of capacity 100/125 KVA, including connecting and testing all as specified and directed.
(a) Air Filter
(b) V Belt
(c) Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 63 KVA, Model GIR 20OSL & NRF 225/2 Make :Greaves including connecting and testing all as specified and directed.
(a) Air filter
(b) V Belt
(c) Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 50/40 KVA,Type 4R 1040 Make :Kirlosker including connecting and testing all as specified and directed.
(a) Air filter
(b) V Belt
M & L for replacement of defective spare parts of DG Sets of capacity 30 KVA,Model- S 3804 & NB 200M Make :Greaves including connecting and testing all as specified and directed.
(a) Air filter
(b) V Belt
(c) Hose Pipe Set
M & L for replacement of Door Hinges of various capacity of DG Set
Supply and fixing battery lead with negative & Positive brass terminals of suitable size with 3 m length of each lead all as directed
M & L for complete checking of AMF panel,finding the fault,servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations allas directed. ( Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule.)
Supply only AMF Relay
M&L for replacement of UNSV contactor AC operated 4 pole 415 volts suitable for the following capacity of DG set
(a) DG set 320 KVA
(b) DG set 250 KVA
(c) DG set 200 KVA
(d) DG set 160 KVA
(e) DG set 100 KVA
(f) DG set 75 KVA
(g) DG set 50/40 KVA
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 320 KVA /250 KVA/ 200 KVA
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 100 KVA /125 KVA
S&F single phase preventor SPPR type SDz5, SPPR + Timer, 415 volts, 50 Hz, suitable for 3 phase DG Panel. Make : L&T Cat No XM81809OOOO or SEIMENS / BCH
S&F Electronic timers type ST100 , 415 volts, 50 Hz, suitable for 3 phase DG Panel. Make : L&T Cat No ST80328OOOO
S&F in replacement of window glass of canopy of capacity 500 KVA
S&F in replacement of window glass of canopy of capacity 63 KVA
S&F in replacemnt of heat proof asbestos rope 12 mm to 20 mm dia on engine exhaust pipe including dismataling of worn out asbestos rope and minor welding tightening in leakage of exhaust pipe complete all as directed confirming to IS specifications of fire proof/flame proof
Taking outold unserviceable battery charger from the following DG sets replacemnt with the following battery charger of suitable capacity and checking the terminals including petroleum jelly and spray cleaning and getting test certificate to produce Engr-in-charge for the following capacities of DG sets all as specified and directed.
Battery charger 24 volts 20 Amps capacity panel mounted suitable for 500 KVA DG set complete all as directed.
Battery charger 24 volts 10 Amps capacity panel mounted suitable for 200/250/320 KVA DG set complete all as directed.
Battery charger 12 volts 20 Amps capacity panel mounted suitable for 100/125 KVA DG set complete all as directed.
Battery charger 12 volts 10 Amps capacity panel mounted suitable for 30/40/50/62.5 KVA DG set complete all as directed.
UNIVERSAL ENGINEERING
M/S SRI BALAJI ENTERPRISES
Lucky Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .