Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹42.7 L+₹4.2 L (10.9%)Rejected-AOC | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹43.1 L+₹4.6 L (11.8%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹43.3 L+₹4.8 L (12.4%)Rejected-Finance INDIRA HATIA BIRBHUM | BIRBHUM | WEST BENGAL | L4 | Rejected-Finance Being L4 Bidder |
| Sl No | Description | Qty | Unit | M/S. S. D. CHATTERJEE AND CO. L3 | AJOY KUMAR DAS L2 | B M ELECTRIC L4 | MUKHERJEE LIGHT DECORATOR L1 |
|---|---|---|---|---|---|---|---|
| 1.01 | PART-A : EVM Commissioning & Strong Room (FROM 13/04/2026 TO 06/05/2026---- 25 DAYS.
SUB HEAD-1. CONTROL PANEL AND SWITCHES:- Providing on hire basis of floor mounting Cubical LT Panel on suitable angle iron chair frame with the following switchgears ( MCCB/Main switch, Changover, Cable alloy etc.) and measuring instruments for safely distribution of both Supply power & DG power feed to building. Including providing inter connections wiring from source to pannel, socketing, earthing attachment etc. & dismantling the same at the end of the programme as per direction of E.I.C. ( All material is to be fixed and connected as per P.W.D. standard )
with mimimum following accesseries-
Incoming: -
(a) 415 V, 200 A TPNIC switch with HRC fuse - 1(One) No.
(b) 415 Volt, 200Amp. FP Change Over Switch - 1(One) No.
(c) 400A, 4 Bar copper/ AL Busbar Chamber -1 Set
Out going & Measuring lnstruments: -
(a) 415 V, 63 A TPNIC switch with rewire-able type fuse - 2(Two)No. (b) 415 V, 100 A TPNIC switch with rewire-able type fuse - 2 (Two)
(c) RYB indicating lamp - 3 Nos.
(d) E. I. Danger Board - 1 No.
(e) Volt meter (0 - 600 volt.) with Selector Switch - 1 No.
Up to 3 days - | 1 | No | 3,635 ₹3,635 | 3,635 ₹3,635 | 3,635 ₹3,635 | 2,400 ₹2,400 Lowest |
| 2.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials)
415 Volt,200 Amp. TPNIC Main Switch with cut out -
Up to 3 days - | 2 | No | 617 ₹1,234 | 617 ₹1,234 | 617 ₹1,234 | 265 ₹530 Lowest |
| 3.00 | 415 Volt,100 Amp. TPNIC Main Switch with cut out -
Up to 3 days - | 2 | No | 411 ₹822 | 411 ₹822 | 411 ₹822 | 235 ₹470 Lowest |
| 4.00 | 415 Volt,63 Amp. TPNIC Main Switch with cut out -
Up to 3 days - | 10 | No | 298 ₹2,980 | 298 ₹2,980 | 298 ₹2,980 | 180 ₹1,800 Lowest |
| 5.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials)
415 Volt, 200 Amp. FP Change Over Switch
Up to 3 days - | 4 | No | 694 ₹2,776 | 694 ₹2,776 | 694 ₹2,776 | 340 ₹1,360 Lowest |
| 6.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials)
415 Volt, 100 Amp. FP Change Over Switch
Up to 3 days - | 2 | No | 629 ₹1,258 | 629 ₹1,258 | 629 ₹1,258 | 280 ₹560 Lowest |
| 7.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials)
415V, Upto 8 Way 160 amp,VTPNDB With 100/160 amp MCCB As Incoming 8 No. - 100 amp FPMCB as Outgoing
Up to 3 days - | 1 | No | 1,144 ₹1,144 Lowest | 1,144 ₹1,144 Lowest | 1,144 ₹1,144 Lowest | 1,350 ₹1,350 |
| 8.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials)
415V, Upto 6 Way TPNBDB With 1 No. - 63 amp FPMCB as Incoming & 15No. 6-32 amp SPMCB as Outgoing
Up to 3 days - | 6 | No | 363 ₹2,178 Lowest | 363 ₹2,178 Lowest | 363 ₹2,178 Lowest | 380 ₹2,280 |
| 9.00 | Providing on hire basis following switches etc. on wooden plank board or suitable angle iron frame incl. Providing inter connection wiring with socketing, earthing attachment etc. and dismentaling at the of end function (with PWD / E.I.C. approved materials)
a) 240V, 2+12 Way SPNBDB With 6 - 32 amp SPMCB as Outgoing & 40/63 amp DPMCB as Incoming.
Up to 3 days - | 16 | No | 242 ₹3,872 Lowest | 242 ₹3,872 Lowest | 242 ₹3,872 Lowest | 280 ₹4,480 |
| 10.00 | ii) 2 Core 6/10/16 Sq. mm PVC / XLPE armorured cable per meter
Up to 3 days - | 2,150 | mtr | 37 ₹79,550 | 37 ₹79,550 | 37 ₹79,550 | 14 ₹30,100 Lowest |
Tender Value
Refer Docs
EMD Value
₹85,615
Closing Date
6 Apr 2026, 1:00 pmClosed
EXECUTIVE ENGINEER Birbhum Electrical Division
Office of The EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri,Dist Birbhum, Pin 731101
Temporary Electrification work for EVM commissioning, Strong room, DCRC and Counting arrangement within the campus of Bolpur High School and Bolpur College in connection with WBLAE 2026 for 286 Bolpur and 287Nanoor in the Dist. of Birbhum
2026_WBPWD_5013725_1
BIRED/132/e-NIQ(1st call) of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
4 days
Bolpur birbhum
Please refer Tender documents.
6 documents required · 6 mandatory
₹85,615
Birbhum Electrical Division
7 Jul 2026
27 Mar 2026
8 Apr 2026
27 Mar 2026
6 Apr 2026
30 Mar 2026
30 Mar 2026
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
Tendernotice_2.pdf
PDF • 0.52 MB
BOQ_5081502.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .