Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAdmitted-Finance | ₹4.8 L | L1 | Admitted-Finance |
| 2 | L2₹4.8 L+₹1,331.40 (0.28%)Admitted-Finance | ₹4.8 L+₹1,331.40 (0.28%) | L2 | Admitted-Finance |
| 3 | L3₹4.8 L+₹4,047.40 (0.85%)Admitted-Finance 0 0 0 NEAR DAK BUNGLOW NH 1 A NH 1A UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹4.8 L+₹4,047.40 (0.85%) | L3 | Admitted-Finance |
| 4 | L4₹5.3 L+₹52,021.40 (10.9%)Admitted-Finance | ₹5.3 L+₹52,021.40 (10.9%) | L4 | Admitted-Finance |
| 5 | L5₹6.0 L+₹1.2 L (25.6%)Admitted-Finance | ₹6.0 L+₹1.2 L (25.6%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L6 | P.K. Electricals L1 | Shakti Trading Co. L7 | Developers L4 | N.K. BUILDCOM L2 | ASHMITA ENGINEERS AND TRADERS L5 | Shivam Enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(SOR 31.5.2) | 30 | Points | 16,200 ₹16,200 | 15,000 ₹15,000 | 22,500 ₹22,500 | 15,000 ₹15,000 | 24,000 ₹24,000 | 9,000 ₹9,000 Lowest | 13,500 ₹13,500 |
| 1.02 | Wiring of light/power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable foe loop earthing as required. (SOR 31.5) | 10 | Points | 3,850 ₹3,850 | 4,530 ₹4,530 | 7,500 ₹7,500 | 4,000 ₹4,000 | 3,000 ₹3,000 Lowest | 4,500 ₹4,500 | 3,100 ₹3,100 |
| 1.03 | Supplying and fixing suitable size GI box worth modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc as required. (SOR 31.31) | 10 | Nos. | 4,050 ₹4,050 | 4,770 ₹4,770 | 6,500 ₹6,500 | 4,000 ₹4,000 | 5,500 ₹5,500 | 4,300 ₹4,300 | 2,950 ₹2,950 Lowest |
| 1.04 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 p[in 5/6 A & 15/16 A modular socket outlet and 15/16 modular switch, connection s ets as required. (SOR 31.32) | 5 | Nos | 2,490 ₹2,490 | 2,930 ₹2,930 | 4,250 ₹4,250 | 2,500 ₹2,500 | 2,750 ₹2,750 | 2,250 ₹2,250 | 1,900 ₹1,900 Lowest |
| 1.05 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections powder pained including earthing etc. 4 way (4+12), Doubledoor (SOR 32.4.1) | 1 | Nos | 3,250 ₹3,250 | 3,500 ₹3,500 | 3,500 ₹3,500 | 3,500 ₹3,500 | 800 ₹800 Lowest | 2,300 ₹2,300 | 2,550 ₹2,550 |
| 1.06 | Supplying and fixing 5A to 32A rating, 240/415V, 10KA C curve, Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required pole. Double pole (SOR 32.10.3) | 10 | nos | 5,550 ₹5,550 | 6,560 ₹6,560 | 12,500 ₹12,500 | 4,000 ₹4,000 Lowest | 8,000 ₹8,000 | 4,500 ₹4,500 | 5,100 ₹5,100 |
| 1.07 | Supplying and fixing following rating, double pole, 240,415 V, isolator in the existing MCB 4 pole complete with connections, testing and commissioning etc. as required 63 AMP. (SOR 32.12.2) | 4 | Nos | 1,852 ₹1,852 | 2,108 ₹2,108 | 6,000 ₹6,000 | 1,600 ₹1,600 | 4,800 ₹4,800 | 16,000 ₹16,000 | 1,360 ₹1,360 Lowest |
| 1.08 | Wiring for circuit /Submain wiring along with earth wire with the following sizes of FRLS PVC insulted copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2x1.5sq.mm+ 1x1.5sq.mm earth wire. (SOR 31.7.1) | 450 | Mtr | 1,19,250 ₹1,19,250 | 67,500 ₹67,500 | 58,500 ₹58,500 Lowest | 1,35,000 ₹1,35,000 | 67,500 ₹67,500 | 1,80,000 ₹1,80,000 | 94,500 ₹94,500 |
| 1.09 | 2x2.5sq.mm+ 1x2.5sq.mm earth wire. (SOR 31.7.2) | 300 | Mtr | 90,600 ₹90,600 | 60,000 ₹60,000 | 46,500 ₹46,500 | 84,000 ₹84,000 | 45,000 ₹45,000 Lowest | 51,000 ₹51,000 | 63,000 ₹63,000 |
| 1.10 | 2x4sq.mm+ 1x4 sq.mm earth wire (SOR 31.7.3) | 250 | Mtr | 85,000 ₹85,000 | 62,500 ₹62,500 | 56,250 ₹56,250 | 67,500 ₹67,500 | 75,000 ₹75,000 | 45,000 ₹45,000 Lowest | 77,500 ₹77,500 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
1 Aug 2026, 3:15 pmClosed
EE SDW XII
DELHI JAL BOARD ROHINI SECTOR 25 DELHI
Improvement of internal and external lighting system of Rohini Sector 26 SPS
2026_DJB_295885_7
NIT NO. 05(2026-27)
Open Tender
Miscellaneous Works
Item Rate
30 days
ROHINI SECTOR 25 DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 06121000095461
₹16,000
Yes
6 Aug 2026
25 Jul 2026
1 Aug 2026
25 Jul 2026
1 Aug 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(SOR 31.5.2) | 30 | Points | 80 | ₹2,400 |
| 1.02 | Wiring of light/power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable foe loop earthing as required. (SOR 31.5) | 10 | Points | 80 | ₹800 |
| 1.03 | Supplying and fixing suitable size GI box worth modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc as required. (SOR 31.31) | 10 | Nos. | 80 | ₹800 |
| 1.04 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 p[in 5/6 A & 15/16 A modular socket outlet and 15/16 modular switch, connection s ets as required. (SOR 31.32) | 5 | Nos | 80 | ₹400 |
| 1.05 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections powder pained including earthing etc. 4 way (4+12), Doubledoor (SOR 32.4.1) | 1 | Nos | 80 | ₹80 |
| 1.06 | Supplying and fixing 5A to 32A rating, 240/415V, 10KA C curve, Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required pole. Double pole (SOR 32.10.3) | 10 | nos | 80 | ₹800 |
| 1.07 | Supplying and fixing following rating, double pole, 240,415 V, isolator in the existing MCB 4 pole complete with connections, testing and commissioning etc. as required 63 AMP. (SOR 32.12.2) | 4 | Nos | 80 | ₹320 |
| 1.08 | Wiring for circuit /Submain wiring along with earth wire with the following sizes of FRLS PVC insulted copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2x1.5sq.mm+ 1x1.5sq.mm earth wire. (SOR 31.7.1) | 450 | Mtr | 80 | ₹36,000 |
| 1.09 | 2x2.5sq.mm+ 1x2.5sq.mm earth wire. (SOR 31.7.2) | 300 | Mtr | 80 | ₹24,000 |
| 1.1 | 2x4sq.mm+ 1x4 sq.mm earth wire (SOR 31.7.3) | 250 | Mtr | 80 | ₹20,000 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_393747.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .