Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹13.3 L+₹7,908.12 (0.60%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
14 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
PROVN OF CERTAIN REVENUE AND MINOR WORKS AT 8 FBSU, AF STATION AWANTIPUR
2020_MES_377945_2
GE (AF) AWA-15/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹30,000
Yes
27 Nov 2020
16 Oct 2020
16 Nov 2020
16 Oct 2020
14 Nov 2020
24 Oct 2020
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. not exceeding 10 sqm on plan and not exceeding 1.5metre in depth and getting out in soft/loose soil, complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out and removing surplus soil to a distance n.exc. 50m and making good surface in soft/ loose soil , complete all as specified and as directed.
Returning filling in, soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and as directed.
Removing of excavated material (soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5metre high from the starting point, complete all as specified and as directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and as directed.
Brick work with old size bricks having crushing strength not less than 75Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4, complete all as specified and as directed.
Plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in lintels upto 1.50 metres clear span, steps, seismic and other similar bands, coping, bed plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating, and use of form work (straight or curved) complete all as specified and as directed.
Hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to true surface, complete all as specified and as directed.
Plain cement concrete, 1:5:10, type E-2 using 40mm graded crushed stone aggregate for foundation filling, mass concrete and sub base of floors, complete all as specified and as directed.
Plain cement concrete 1:3:6, type C- 1, using 20mm graded crushed aggregate, 50 mm thick, as in plinth protection, laid in alternate bays, finshed even and smooth without using extra cement having 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between walling and plinth protection, the joint of bays of concrete shall be filled with mastic filling comprising of one part of heated bitumen 85/25 or 90/100 grade and three parts of sand (all by weight), complete all as specified and as directed.
Rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed.
Plain cement concrete, 1:2:4, type B-0 using 12.5mm graded crushed stone aggregate, 25mm thick, surface finished fair to receive top layer of flooring, complete all as specified and as directed.
Machine cut kota stone slab 18 to 22 mm thick, as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, laid over and including 15 mm thick screed bed or bedding layer in cement mortor 1:4, complete all specified and as directed
Steel windows or ventilators side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete, with glazing bars, dovetailed or welded , complete all as specified and as directed.
Sheet glass, ordinary quality, 3mm thick, glazing with oil putty in squares, not exceeding 0.50sqm in each pane, in steel windows, complete all as specified and as directed.
Plywood, grade BWP, 6mm thick, type BB with 5 Nos of ply, fixed with screws to mild steel frame work as in ceiling, including necessary wooden fillet of appropriate size, complete all as specified and as directed.
2nd class soft wood (Kail) clean swan, timber framed and fixed as in scantlings for frame work for ceiling, complete all as specified and as directed.
2nd class soft wood (Kail) Plain fillets, square,rectangular or triangular in section, exceeding 3 sq.cm but not exceeding 6 sq.cm in sectional area, clean sawn, se-cured with nails or brads, complete all as specified and as directed.
Rolled mild steel as in roof trusses (framed), trussed, posts, struts, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, base plate and gusset plates etc confirming to Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Rolled mild steel work as in doors or gate of angle of other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting(exlusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing , conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and as directed.
Galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hook bolts with washers in roof, 0.63mm thick, grade-O quality, with 120gms/sqm zinc coating and grade 'B' Class 8, complete all as specified and as directed.
Galvanised, plain mild steel sheeting, fixed with 'L' type or 'J' type or cranked hook bolts with washers, in ridges, hips, vally gutters drip and straight flashings (length and girth as fixed) , 0.63mm thick, grade-O quality, with 120gm/sqm zinc coating, complete all as specified and as directed.
Preparation of newly untreated CGI/PGI steel sheets of any description, over 10cm width or girth, not otherwise described ,and applying two coats of synthetic enamel paint in camouflage pattern (Green,grey, brown ) over a coat of red oxide or zinc chromate primer, complete all as specified and as directed.
Preparation of newly untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate,complete all as specified and as directed.
Preparation of new plastered/unplastered surfaces of walls and applying three coats of white wash, complete all as specified and as directed.
Preparing new plastered or un-plastered surfaces of walls and applying two coats of Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern (Green, Grey and Brown colour) over a coat of acrylic primer, complete all as specified and as directed.
Plain cement concrete, 1:3:6, type C-2 using 40mm graded crushed stone aggregate, 75mm thick, as in sub-base of floor etc. finishing surfaces even and fair, complete all as specified and as directed.
Plain cement concrete, 1:2:4 type B-1, using 20mm graded crushed stone aggregate, 75mm thick, as in floors, finishing surfaces even and smooth without using extra cement, complete all as specified and as directed.
Installation, testing and commissioning of Chemical Earthing complete with copper plate electrode of size 900mmx600mmx5mm, buried directly in ground vertically to a depth not less than 4.5 metre below normal ground level and complete size of pit 1.2mx1.2mx5.1m, earth plate electrode connected to and including copper earth strip 32 x 6 mm as main earthing lead by means of tinned copper / brass bolts, nuts, check nuts and washers besides brazing at all joints as directed and protected with 40mm dia light grade GI pipe from electrode and upto including the earth test point, 20 mm dia watering pipe light grade GI pipe including funnel, wire mesh, alternate layers of thickness 150mm each of charcoal, common salt, magnesium sulphate/chemical as per manufacturer recommendation around copper electrode plate including one layer of each below and above the plate, including excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate, RCC cover 50mm thick in RCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with 8 mm dia MS deformed bars @ 75mm c/c both ways including MS angle iron frame of size 40mmx40mmx3mm including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I and as directed .
Test point terminal block for chemical earthing made of gun metal or phosphorus bronze of size 75x75x25mm drilled and srewed including 3 Nos 8mm dia, 25mm long hex head srew, complete all as specified and as directed.
Earth continuty conductor or main earthing lead, copper strip of size 20x3mm fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required , complete all as specified and as directed.
Flame proof point wiring complete with multi stranded copper conductor 1.5 sqmm, PVC insulated, FRLS type, unsheathed cable 1100 V grade drawn in and including 1.6 mm thick ERW stove enamelled rigid steel concealed conduit of size not less than 20 mm dia including flame proof fittings such as MS junction box, MS coup-lings, unions, bends, reducers, inspection elbow, sealing compound conduit, plugs and also including single core multi stranded copper conductor 1.5 sqmm PVC insulated, unsheathed, FRLS type cable as earth wire and connected to earth terminal and the body of the flame proof lumiaires and drawn in the same concealed conduit complete all as specified and directed for one flame proof light/fan point controlled by single pole one way switch. Note:- Cutting chases for concealed conduit and making good in cement mortar to match with existing surface is deemed included in unit quoted rate.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed.
Flame proof LED tube light fitting 1x20 Watt surface mounting including LED tube rod and connecting electrically using FRLS cable flexible of size 1 sqmm 3 core overall sheathed , complete all as specified and as directed. Make:- Crompton cat pt No-EXTN1LT8-16/20 or equivalent in Bajaj / Havells
Distribution board enclouser 4 way made out of galvenised steel sheet class EX II housed with MCBs of following capacities, complete all as specified and as directed:- i) MCB SPN 10 KA breaking capacity 32 Amps -01 No ii) MCB SP 10 KA breaking capacity 6-16 Amps -02 Nos Note: The enclouser and MCB should be flame proof with explosion protection suitable for Zone-1 . All accessories requires for connection included in the rates shall be quoted by the contractor. Make : Shyam switchgears/Sudhir.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit inplain cement concrete 1:2:4, type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I and as directed .
Supply and fixing air cooled (AC) inverter type split unit air conditioner electric driven, single phase, 230 volts, AC of capacity of 1.5 TR, BEE 4 star rated cooling and heating function complete with cordless remote control unit and with mounting arrangments, complete all as specified and as directed. Make : Bluestar/LG/Samsung/Hitachi/Godrej
Supply and fixing Voltage stablizer for automatic operation, naturally air cooled indoor type energy efficent and designed for single phase operation of capacity 5 KVA for input variation between 170 to 280 volts with output voltage stablized at 230 vollts with accuracy + 5%, complete all as specified and as directed. Make : V Guard/Vinitec/Sinetrac/Microtek/Powerware
Supply, installation and testing energy efficient, water heater storage type, BEE 5 star rated of capacity 25 litres having steel tank with all asscessories such as air release valve, CP connections for hot and cold supply including fixing arrangement , complete all as specified and as directed.
Bib taps, 15mm bore, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed.
Brass chromium plated mixer, 15mm bore, for mixing hot and cold water, wall mounted, screwed for iron pipea and fixed, complete all as specified and as directed.
Stop valve, 15mm bore ,cast copper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed.
Mild steel galvanised iron medium grade water tubing 15mm bore with screwed and socket joints, with all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to wall and ceiling or laid under floors, complete all as specified and as directed.
Cutting of existing water supply main any size upto 25 mm bore for taking branch connection of size 15 mm bore including insertion of Tee of size 25mmx25mmx15mm bore, complete all as specified and as directed.
Point wiring complete with 2 single core PVC insulated unsheathed FRLS type, 1100 volts ,multi stranded copper conductor cable 2.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core 2.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity cable, for 15 Amps switch socket outlet etc. complete all as specified and as directed.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping of suitable size (ISI marked) and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB up to 20 amp, 240 volts , complete all as specified and as directed.
Sheet metal enclosure DB's SPN, 2 way, single door, 230 volts IP-43 protection AC, concealed type without busbar, neutral link and earth link suitable for MCBDP/SPN as incomer and MCB SP as outgoing including, grouting in wall and making good to disturbed surfaces to match existing, complete all as specified and as directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, unsheathed, FRLS type, 1100 volts grade,1.5 sqmm copper conductor cable unsheathed as earth continuity cable for One 3/5 pin socket outlet, 5/6 Amp on the same board controlled by one No, one way switch, complete all as specified and as directed.
Piano type switch socket combination, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed.
Sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
MCB SP, 6-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and as directed.
MCB SPN, 6-32 Ampss, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and as directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and as directed.
Sheet metal enclosures triple pole and earth enclosure with a three pin and earth plug with socket complete with triple pole 32 Amp MCB, complete all as specified and as directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, unsheathed, FRLS type, 1100 volts grade,1.5 sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal box not less than 1.2mm thick with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators for one light /fan/bell point controlled by one No, one way 5/6 Amps switch, complete all as specified and as directed.
Description all as per serial item No. 59 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and as directed.
LED tube light fitting, box type 230 volts AC suitable for & including 18/20 watts LED tube rod with bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size , complete all as specified and as directed. Make: Havells Model: Regal batten for Fitting and Photon Ultra LED for tube rod or equivalent in Philips/Crompton.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed .
Flood light with turbo LED flood light fixture of 120 Watts LED with secondary optics made in pressure die cast housing with heat sink and aluminium extrusion with IP 66 degree of protection, individual LED's must have secondary lense for better throw across, complete all as specified and as directed. Make:- Bajaj Cat part No BJFL 120 W LED or equivalent in Philips/Havells
Supply, testing, laying/fixing of XLPE Insulated cable with wall using fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc alongwith walls/poles etc. ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm 2 core, complete all as specified and as directed .
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 70Sqmm, 3.5 core including making electrical connections, complete all as specified and directed.
Sand cushioning to underground cable 8 cm thick layers below the cable and 15 cm thick above the cable in trenches using fine screened river sand, complete all as specified and as directed. Note :- Punned thickness shall be measured and paid.
Well burnt old size sub class 'B' bricks of nominal size 230X115X075 mm abutting each other for cable protection, complete all as specified and directed.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz, complete all as specified and as directed.
Wall mounting fan 230 volts, single phase, 400 mm sweep complete with suitable copper connecting cable and connecting up complete with all standard fixing accessories, complete all as specified and as directed. Make: Havells make model No. Platina HS or equivalent in Crompton/Khaitan.
M/S GEE EMM MIR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .