| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.6 L+₹2.5 L (8.10%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹33.8 L+₹2.8 L (8.86%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹34.0 L+₹2.9 L (9.43%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹34.5 L+₹3.4 L (10.9%)Rejected-Finance B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR/MAINTENANCE/REPLACEMENT OF PERIMETER LIGHTS/SECURITY LIGHTS PHOTO SENSITIVE AUTOMATIC ON/OFF DEVICES AND OTHER CONNECTED WORKS AT 39 WING AF STN UDHAMPUR
2022_MES_564689_1
GE/AFU-56/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE AF Udhampur
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹76,000
Yes
17 Dec 2022
23 Nov 2022
15 Dec 2022
23 Nov 2022
13 Dec 2022
8 Dec 2022
23 Nov 2022 - 29 Nov 2022
Amount
Repair and replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, PF>= 0.90, lumen efficacy >= 100 lumen/watts, 5700 K, including new lights to be fixed in existing bracket at existing pole/bldg or other extra welding works complete all as specified including taking down old. Make : HPL cat part No HPLLEDSL6060E Havells/Bajaj/C&S/Crompton/Polycab or equivalent as approved by GE Note for items ser no 1 to 4 :- (i) T&P required for repair/mantenance such as ladder, Crane vehicle, hydra, menpower etc, are inclusive in the item rate. (ii) Rate of necessary arrangement for fixing LED light on existing bracket like reducer or extention of pipe by suitable size of GI pipe as per dia of LED light by welding etc are inclusive in the item rate.)
Repair and replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, PF>= 0.90, lumen efficacy >= 100 lumen/watts, 5700 K, including new lights to be fixed in existing bracket at existing pole/bldg or other extra welding works complete all as specified and as directed. including taking down old. Make : HPL cat part No HPLLEDSL9060E /Havells/Bajaj/C&S/Crompton/Polycab or equivalent as approved by GE
Repair and replacement of LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, PF>= 0.90, lumen efficacy >= 100 lumen/watts, 5700 K, including new lights to be fixed in existing bracket at existing pole/bldg or other extra welding works complete all as specified and as directed. including taking down old. Make : HPL cat part No HPLLEDSL12060E /Havells/Bajaj/C&S/Crompton/Polycab or equivalent as approved by GE
Supply & fixing of 150 watt LED light energy saving and enviromental friendly long life versatile pressure dia cast aluminium IP66 roadway luminaire with high power LED as light source of capacity 150 watts ,5700 /3000 Degree kelvin with suitable driver and surge protection and all standard accessories etc complete all as specified including taking down old. Make : Havells HSN code 9405 or equivalent as approved by GE. Make : HPL cat part No HPLLEDSL15060E /Havells/Bajaj/C&S/Crompton/Polycab or equivalent as approved by GE
S & F street light bracket made out of 40/50 mm dia GI heavy grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers complete all as specified and as directed including taking down old.
Supply and fix 1.5 Sqmm 2 core cable, PVC insulated and PVC round sheathed, copper conductor(flexible) industrial cable, 1100 volt, confirming to IS :694 including replacement of old unsv cable complete all as specified and as directed by Engineer-in-Chage. Note- (i) Cable is reqd to be connected from street light to junction box with proper lugs.
LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced than 205mm x 255mm x 112 mm(the cable size upto 25 sqmm). The polycarbonate junction box shall be environmental friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529.Weatherproof, UV resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998. The Junction Box with 25Amp Connectors or Terminal Trip or Bus Bar. The Junction Box / Enclosure shall be tested as per IEC including one No. 4 pole connector and chromium plated clamps and nut bolts, cable glands with lock nuts of 2 Nos for each box complete all as per manufacturer’s complete all as specified and as directed by Engineer-in-Chage. Make : Cat Part :- KF 2525 B of Hensel/Siemens/GE Power/Rittal/Legrand
Supply and fixing of GI tubing medium grade 40 mm bore cut to size and fixed along the pole /road cable protection all as required at site or complete all as specified and as directed including taking down old.
Supply and fixing of GI tubing medium grade 80 mm bore cut to size and fixed along the pole /road cable protection all as required at site or directed by Engineer-in -charge including taking down old.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed of following sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles etc rates shall deemed to be included in the quoted rates).
10 Sqmm, 4 core cable
16 Sqmm, 4 core cable
25 Sqmm, 3½ core cable
35 Sqmm, 3½ core cable
50 Sqmm, 3½ core cable
95 Sqmm, 3½ core cable
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil,complete all as specified and as directed by Engineer-in-Chage.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection complete all as specified and as directed by Engineer-in-Chage..
Automatic street light switch NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch ) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compund (sintex make SMC Junction Box or equivalent as approved by GE ) conforming to IP-54. The contactor, MCB and circuit wiring 16 sqmm copper shall be suitable enough to take load of 25 KW single phase load /8 KW load equally distributed over 3-phase (8 KW/phase), contactor rating 40 Amps(2 pole)and 40 amps 4 pole and MCB (single pole) rating 63 amps (SP-3 Nos) complete including sheet metal enclosure with stand made of suitable size angle iron and grouting of enclosure using cement concrete 1:2:4 type B-I (using 20mm graded crushed stone aggregate) complete all as specified and as directed by Engineer-in-Chage. including taking down old. Make :- Healer and Model No. SWADEEP-02EC25kW 3 PHASE .
M & L in replacement of LED Driver with surge protector suitable for 60 to 90 watt LED fitting with universal voltage 90-300 volts alternating current ,short circuit,over temperature and over load protection complete all as specified and directed by Engr-in-charge .Make C&S/ Wipro /Philips/syska/havells/Bajaj or equivalent as approved by GE. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
M & L in replacement of LED Driver with surge protector suitable for 120 to 150 watt LED fitting with universal voltage 90-300 volts alternating current ,short circuit,over temperature and over load protection complete all as specified and directed by Engr-in-charge.Make C&S/ Wipro /Philips/syska/havells/Bajaj or equivalent as approved by GE. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only following accessories/spares parts :-
M&L for 4 pole contactor Ie 40 Amps,Ue415 volts,Ui 1000 volts ,IS/IEC 60947-4-1 including auxilary contact Ie AC-15:4A 415 V- Ith 10/6 A all accessories complete all as specified and as directed by Engineer-in-Chage. including taking down old.
M&L for 4 pole contactor Ie 65 Amps,Ue415 volts,Ui 1000 volts ,IS/IEC 60947-4-1 including auxilary contact of 2 No and NC, 415 V- Ith 10/6 A all accessories complete all as specified and as directed by Engineer-in-Chage. including taking down old.
M & L for Timer Switch Electronic digital type complete all as specified and as directed
M & L for Analog timer switch complete all as specified and as directed
M & L for Energy Conzerv meter for timer of series No DM6100,VAF,PF meter, Accuracy CI0.5,CI1.0 complete all as specified and as directed by Engineer-in-Chage.
Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 250 Amps with breaking capacity 35/36 KA complete all as specified and as directed by Engineer-in-Chage. . Make :- Standard/Havells/Schneider/ABB or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 100 Amps with breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Chage. . Standard/Havells/Legrand or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 160 Amps with breaking capacity 35/36 KA complete all as specified and as directed by Engineer-in-Chage. Make :- Standard/Havells/Legrand or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 400 Amps with breaking capacity 35/36 KA complete all as specified and as directed by Engineer-in-Chage Standard/Havells/Schneider/ABB or equivalent as approved by GE.
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
Outdoor/indoor 120 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable complete all as specified and directed
Outdoor/indoor 95 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable complete all as specified and directed
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable complete all as specified and directed
Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-
Straight through joint kit indoor/outdoor al conductor cable of size 150 to 185 Sqmm and 3.5/4 core complete all as specified and as directed by Engineer-in-Chage.
Straight through joint kit indoor/outdoor al conductor cable of size 25 to 35 Sqmm and 3.5/4 core complete all as specified and as directed by Engineer-in-Chage.
Straight through joint kit indoor/outdoor al conductor cable of size 50 Sqmm and 3.5/4 core complete all as specified and as directed by Engineer-in-Chage.
Straight through joint kit indoor/outdoor al conductor cable of size 95 Sqmm and 3.5/4 core complete all as specified and as directed by Engineer-in-Chage.
Supply, installing, testing and commissioning CPRI approved factory made and tested LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-54) and made of 3.15 mm thick CRCA SHEET & suitable frame work/ support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete and PCC (1:3:6) type C-2 foundation of size including connections of all out going/in coming existing cables of any size by drawing /digging out cable inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board and taking out of old skelton type panel with control switches complete all as specified and as directed by Engr-in-Charge. including the following items incorporated same panel and removed old unserviceable panel.The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp insulated copper strip of length not less than 60 cm and 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8 Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 250 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50 Hz,=01 OUTGOING SUPPLY :- (i) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 40 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos. Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
M&L for cutting the existing cable from loop and making end termination with aluminium lugs without jointing kit with cable glands suitable for LT U/G cable complete all as specified and directed of following sizes:-
120 x 3.5 to 185 x 3.5 sqmm .
50 x 3.5 tgo 95 x 3.5 sqmm .
16 x 3.5 to 50 x 3.5 sqmm
Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m complete all as specified and directed by Engineer-in-Charge.
Laying only LT UG cable 10 sqmm x 4 core to 185 sqmm x 3.5 core cable shall be provided under Sch 'B'/underground the existing cable etc making all electrical connections as directed by Engr-in-Charge. Note :- 1. Execavation shall be got done alongwith other items of cable required for laying of cable and shall be paid in respective items for laying existing overground cables. 2. Laying of existing cable shall be done through department labour/employee.
M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC covercomplete all as specified and as directed by Engineer-in-Chage. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Painting to steel tubular swaged poles 9/11 mtr long complete (above the perimeter wall portion) including all MS work mounted on pole, earth protection & with pipe (if exists) with one coat of aluminium paint and synthetic enamel paint from top of perimeter wall / PCC coping and numbering of poles with white synthetic enamel paint on black back ground complete all as specified and as directed by Engineer-in-Chage.
Disconnecting and dismantling the electrical connection and shifting of Lt Panel boards by disconnecting incoming and outgoing cable including all accessories including nut, bolt, washer and thimble etc complete and refixing of the Lt panel on staging by embedding the panel legs minimum 30 cm in ground/staging and adding a layer of PCC 1:2:4, 100 mm thick and re-connecting base of panel shall be atleast 45 Cm from ground level. All metal work like provn of glands, civil work etc shall be deemed to be included in quoted rates all as specified and directed by Engr-in-Charge.
Disconnecting and dismantling the electrical connection and shifting of electrical poles by disconnecting incoming and outgoing cable including all accessories complete and refixing the pole by excavation, returning & filiing and removal of any type of soil including PCC 1:3:6 type C-2 with using 40 mm graded crushed stone aggregate as in foundation and PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping etc for all as specified and directed by Engr-in-Charge
M & L for 3.15 mm CRCA MS Sheet with 02 (two) coat Machine spray paint over one coat red oxide primer/paint alongwith fixing arrangement through nut, bolts or welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge. Note :- Rate include for making the hole in the gland according to the size of cable and re-connecting the cable in the existing panel etc.
Automatic street light switch NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch ) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compund (sintex make SMC Junction Box or equivalent as approved by GE ) conforming to IP-54. The contactor, MCB and circuit wiring shall be suitable enough to take load of 8 KW single phase load /8 KW load equally distributed over 3-phase (7 KW/phase), contactor rating 25 Amps, 4 pole and MCB (single pole) rating 32 amps (SP-3 Nos) complete including sheet metal enclosure with stand made of suitable size angle iron and grouting of enclosure using cement concrete 1:2:4 type B-I (using 20mm graded crushed stone aggregate) all as specified and directed by Engineer-in-Charge including taking down old. Make :- Healer and Model No. SWADEEP-02EC8KW 3 PHASE .
M&L for insulated tape of size 25 mm width , 20 Meter long and 1 mm thick complete all as specified and as directed by Engineer-in-Chage.
Taking down old unserviceable of cable root marker and M&L for cable root marker as per site requirement complete all as specified and as directed by Engineer-in-Chage.
Supply and fixing of DWC HDPE tubing 50 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note for item no 10 and 11 :- (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
Supply and fix 250 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k luminaire engergy saving, environmental friendly long life with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete as specified and directed Make- HPL cat part No HPLLEDFL25060D/Wipro/Crompton or equivalent approved by GE.
Supply and fix 60 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete all as specified and as directed by Engineer-in-Chage. Make- HPL cat part No HPLLEDFL06060F/Wipro/Crompton or equivalent approved by GE.
Supply and fix 120 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete all as specified and as directed by Engineer-in-Chage. and directed.Make- HPL cat part No HPLLEDFL12060F/Wipro/Crompton or equivalent approved by GE.
Supply and fix 150 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 k engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete all as specified and as directed by Engineer-in-Chage. Make- HPL cat part No HPLLEDFL15060F/Wipro/Crompton or equivalent approved by GE
Supply and fix 45 watt LED flood light, with IP 66 protection, PF>=0.90, lumen efficiency >=110 Lm/Watt, 5700 kengergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation incl taking down old one etc complete all as specified and as directed by Engineer-in-Chage. Make- HPL cat part No HPLLEDFL25060D/Wipro/Crompton or equivalent approved by GE.
M&L for type D2 1:4:8 (40 mm graded aggregate) cement concrete in foundation and mass concrete for bricks foundation etc complete all as specified and as directed by Engineer-in-Chage.
M&L for bricks works with sub class B bricks straight or curved on plan exc 6m means radius built in cement mortar 1: 6 etccomplete all as specified and as directed by Engineer-in-Chage.
M&L for type B1 1:2:4 (20 mm graded aggregate) for providing cement concerte in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courese strin course, lacing course string courses lacing courses, parapets, and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Chage.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Note : Total amount of Schedule of Credit for retrieved material mentioned on General summary of Tender documents in PDF format will be deducted offline during acceptance of Tender
DAVINDER SINGH
M/S M P Construction Co
CITY TOP ELECTRICAL WORKS
MAHAJAN TRADING CO
KARAN TRADERS
PAWAN KUMAR GOVT. CONTRACTORS
RANBIR ENTERPRISES
shivom builders
HIMALAYA ENTERPRISES
Kanwal Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .