Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC WARD NO 10 NEHRU PARK ROAD POST SURAJPUR DISTT SURAJPUR C G | SURAJPUR | CHHATTISGARH | 497229 | ₹1.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 LRejected-Finance | ₹1.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹2.0 LRejected-Finance GAWATIYAPARA SHIVNANDANPUR BISHRAMPUR DISTT SURAJPUR CHHATTISGARH 497226 | BISHRAMPUR | SURAJPUR | CHHATTISGARH | 497226 | ₹2.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹2.5 LRejected-Finance | ₹2.5 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | M/S DEEPAK KUMAR PATEL L3 | SHREE SHYAM BABA CONSTRUCTION L1 | M/s ARPIT ENTERPRISES L2 | Indian Electricals and Electranics L4 |
|---|---|---|---|---|---|---|---|
| 1.01 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A. | 38 | Nos. | 432.65 ₹16,440.70 | 337 ₹12,806 | 500 ₹19,000 | 458 ₹17,404 |
| 1.02 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A. | 1 | Nos. | 940.1 ₹940.10 | 733 ₹733 | 800 ₹800 | 996 ₹996 |
| 1.03 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 100 A. | 1 | Nos. | 1,099.9 ₹1,099.90 | 858 ₹858 | 1,300 ₹1,300 | 1,165 ₹1,165 |
| 1.04 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating
voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) .18 Watt. | 20 | Nos. | 1,656.65 ₹33,133 | 1,292 ₹25,840 | 1,700 ₹34,000 | 1,756 ₹35,120 |
| 1.05 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep and Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. | 7 | Nos. | 867 ₹6,069 | 676 ₹4,732 | 700 ₹4,900 | 919 ₹6,433 |
| 1.06 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 150 mm X 60 mm deep | 13 | Nos. | 314.5 ₹4,088.50 | 245 ₹3,185 | 320 ₹4,160 | 333 ₹4,329 |
| 1.07 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | 25 | Nos. | 112.2 ₹2,805 | 87 ₹2,175 | 89 ₹2,225 | 118 ₹2,950 |
| 1.08 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2x4 sq.mm | 50 | Mtr | 156.4 ₹7,820 | 122 ₹6,100 | 125 ₹6,250 | 165 ₹8,250 |
| 1.09 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch | 80 | Nos. | 79.9 ₹6,392 | 62 ₹4,960 | 65 ₹5,200 | 84 ₹6,720 |
| 1.10 | 15/16 amps switch | 18 | Nos. | 169.15 ₹3,044.70 | 131 ₹2,358 | 135 ₹2,430 | 1,799 ₹32,382 |
Tender Value
₹2.4 L
EMD Value
₹3,100
Closing Date
7 Feb 2026, 6:00 pmClosed
SO ENM
GM Office Bishrampur
Electrical wiring of newly constructed Conference Hall and Dining Hall of AITUC Union office of Bishrampur Area.
2026_SECL_351905_1
SECL/GM/BSPR/ENM/216/2025/44 dtd 27.01.2026
Open Tender
Electrical and Maintenance Works
10 days
Bishrampur Area
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,100
8 Jun 2026
28 Jan 2026
9 Feb 2026
28 Jan 2026
7 Feb 2026
28 Jan 2026
28 Jan 2026 - 4 Feb 2026
Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A.
Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A.
Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 100 A.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) .18 Watt.
Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep and Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 150 mm X 60 mm deep
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2x4 sq.mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
15/16 amps switch
3 pin 5/6 A socket outlet
6 Pin 15/16 amps Socket Outlet
Bell Push
Rewiring for light point/ exhuast fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable as earth wire existing surface/ recessed steel/PVC Conduit/Casing Capping dismanteling required. Group A
Group B
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.12 MB
Tendernotice_2.pdf
PDF • 1.33 MB
BOQ_364677.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid