| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | Admitted-Finance |
| 2 | Admitted-Finance 0 RAILWAY STATION ROAD BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹23.3 L
EMD Value
₹23,300
Closing Date
3 Jun 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
se edc balrampur
office se edc balrampur
07/EDC(BLP)/2024-25
2024_MVVNL_925385_3
NVS-05-11/EDC(BLP)/2024-25
Open Tender
Electrical Works
Item Rate
90 days
balrampur
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
se edc blp
₹23,300
12 Jun 2024
24 May 2024
4 Jun 2024
24 May 2024
3 Jun 2024
24 May 2024
Amount
Loading, Unloading and safe cartage of the following materials from Electricity Store Centre, Balrampur to the work site/dump site (Distance up to 50 km)
PCC Poles (8.5 mtr long)
ST Poles (11 mtr long)
PCC Poles (9 mtr long)
ST Poles (13 mtr long)
ACSR Weasel/Dog Conductor/Racoon
33KV Line/Bus Isolater 800Amp.
11KV VCB for outgoing CTR 200/10/5A 350MVA/600/300-5A, 350MVA
11KVA XLPE Cable size 3x185sq.mm
11KVA Indoor/Outdoor Cale Jointing Kit size 3x185sq.mm
33/11KVA XLPE Cable size 3x300sq.mm
11KV Indoor/Outdoor Cable Jointing Kit size 3x300sq.mm
11KV Straight through size 3x185sq.mm
33KV Straight throgh size 3x300sq.mm
ABC 3X95+1X70+1x35 sq.mm.
ABC 3X50+1X35+1X16 sq.mm
Other line materials
Erection of Single PCC Poles (8.5 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site
Erection of sectional Double Pole sectional PCC Pole (8.5 mtr long PCC Pole) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site.
Erection of Single PCC Poles (9 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site
Erection of sectional Double Pole sectional PCC Pole (9 mtr long PCC Pole) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site.
Erection of Single ST Poles (11 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site
Erection of sectional Double Pole sectional ST Pole (11 mtr long PCC Pole) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site.
Erection of Single ST Poles (13 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site
Erection of sectional Double Pole sectional ST Pole (13 mtr long PCC Pole) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site.
Earthing of PCC poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastening with Gl wire to each support by nut & bolt. Earthing rod must be 0.15 Mtr.above from the plinth of the support. All type nut & bolts would be given by the contractor.
Erection of stay set with stay wire, stay clamp & stay insulator including with grouting of stay set by concrete of ratio 1:4:8 as per RESSPO norms before back fitting of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per RESSPO norms. All clamps, nuts, bolts, stay insulator, cement. Brick, ballast, sand etc would be provided by the contractor.
Grouting of PCC/ST Pole at the time of erection of pole in 1:4:8 concrete ratio from bottom of pole to ground level and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing. All material would be provided by the contractor.
Grouting of Stay at the time of erection of stay in 1:4:8 concrete ratio from bottom of stay to ground level by using cement, sand & coarse aggregate in ration 1:4:8 as per RESPO drawing with watering/curing properly upto proper setting of stay. All material would be provided by the contractor.
Laying, stringing, sagging & binding of conductors of 11 KV in 3 phase, 3 wire line with jumpering (where as required)(ACSR Weasel/Dog Conductor/Racoon)
Guarding of 33KV Line
Laying, Stringing & Sagging of ABC Cable up to proper sag for the 3X50+1X35+1X16 sq.mm size cable
Laying of 11KV Cable with proper hosting & looping of following size cable
11KVA XLPE Cable size 3x185sq.mm
33/11KVA XLPE Cable size 3x300sq.mm
Fitting of 11KV Cable Jointing Kit size 3x185sq.mm
Fitting of 33/11KV Cable Jointing Kit/Straight Thourhg size 3x300/3x185sq.mm
Pipe/Comolite Earthing 20/40 Feet with stip (25x5) mm connected to PT & PT Structure
Making Foundation & Structure for 33KV PT/Bus Isulater/33KV VCB
Errection of Bus Bar 33KV
Installation of 11KV VCB
Carriage & Installation of Batery & charger
Decentralized Items:-Providing and fixing of following materials sanctioned Estimate/Package as per RESSPO U.P.P.C.L. drawing/ norms.(where is required).
Dropper, Top Channel, X-Arm, Guarding Angle Holding/"I" Hook clamp.
M.S Channel, M.S Angle
Dead end clamp
Nuts & Bolt.
F-Bracket with nut Bolt.
Top T-off Holding
PG clamp for Dog Conductor
Connector lug
Battery Stand
M/S SMM INFRATECH PVT Ltd
Ms Agarwal Electric Traders
R.S. INDUSTRIAL WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .