| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹55.2 LAccepted-AOC | ₹55.2 L Quoted ₹58.2 L | 1 | Accepted-AOC Lowest quoted bidder, hence accepted |
| 2 | 2₹59.6 LRejected-Finance | ₹59.6 L | 2 | Rejected-Finance Second Lowest quoted bidder, hence rejected |
| 3 | 3₹61.0 LRejected-Finance NO 17 NEW CAUVERY NAGAR THANJAVUR 613 001 | THANJAVUR | TAMIL NADU | 613001 | ₹61.0 L | 3 | Rejected-Finance Third Lowest quoted bidder, hence rejected |
| Sl No | Description | Qty | Unit | SRI JAGATHI CONSTRUCTION L3 | B SARAVANAKUMAR L2 | SIVASUBRAMANIAN RAMASAMY L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling clearing away carefully stacking materials usefull for reused Brick / stone masonry in cement mortar walls under 3m high etc., complete and as directed by the depatmental officers. | 39.68 | m3 | 324 ₹12,856.32 | 317 ₹12,578.56 | 309 ₹12,261.12 |
| 2.00 | Removal of For Doors & windows including removal of frames, hinges and fastenings ect.., | 51.13 | m2 | 177 ₹9,050.01 | 172 ₹8,794.36 | 168 ₹8,589.84 |
| 3.00 | Removal of Gyp board partition upto a ceiling height of 4.5m from floor level. | 80.08 | m2 | 73 ₹5,845.84 | 71 ₹5,685.68 | 69 ₹5,525.52 |
| 4.00 | Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 9mm thick board over the country wood planks. Over the ply wood OST sheet of 4mm thick will be fixed with necessary screws and fevicol giviing neat finish. The top will be finished with two coats of sanding polishing. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmental Officers. The water proof ply wood and OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification. | 215.4 | m2 | 5,784 ₹12.5 L | 5,649 ₹12.2 L | 5,514 ₹11.9 L |
| 5.00 | Dismantling for Plywood sheet 12mm thick including cutting cup washer & scew etc.,complete complying with standard specification and as directed by the departmental officers. | 167.36 | m2 | 150 ₹25,104 | 146 ₹24,434.56 | 143 ₹23,932.48 |
| 6.00Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) | ||||||
| 6.01 | In Ground floor | 8.9 | m2 | 1,178 ₹10,484.20 | 1,151 ₹10,243.90 | 1,123 ₹9,994.70 |
| 6.02 | In First floor | 17 | m2 | 1,202 ₹20,434 | 1,174 ₹19,958 | 1,145 ₹19,465 |
| 7.00Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. | ||||||
| 7.01 | In Foundation and Basement | 4.7 | m3 | 8,762 ₹41,181.40 | 8,558 ₹40,222.60 | 8,353 ₹39,259.10 |
Tender Value
₹55.3 L
EMD Value
₹38,000
Closing Date
9 Apr 2026, 12:00 pmClosed
Superintending Engineer
Office of Superintending Engineer, PWD, Buildings C and M Circle, PWD Campus, Tiruvarur-1.
Providing Dismantling, Redooing the walls, Partitions, Weldmesh and Barricading Arrangements in Counting Hall and Strong Room in AVC Institutions at Mayiladuthurai District for General Elections to Tamil Nadu Legislative Assembly 2026
2026_PWD_675472_1
59-01/ BCM/TVR/2025-26
Open Tender
Civil Works - Others
30 days
Mayiladuthurai
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹38,000
13 Apr 2026
2 Apr 2026
9 Apr 2026
2 Apr 2026
9 Apr 2026
2 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Dismantling clearing away carefully stacking materials usefull for reused Brick / stone masonry in cement mortar walls under 3m high etc., complete and as directed by the depatmental officers. | |||||
| 2Removal of For Doors & windows including removal of frames, hinges and fastenings ect.., | |||||
| 3Removal of Gyp board partition upto a ceiling height of 4.5m from floor level. | |||||
| 4Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 9mm thick board over the country wood planks. Over the ply wood OST sheet of 4mm thick will be fixed with necessary screws and fevicol giviing neat finish. The top will be finished with two coats of sanding polishing. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmental Officers. The water proof ply wood and OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification. | |||||
| 5Dismantling for Plywood sheet 12mm thick including cutting cup washer & scew etc.,complete complying with standard specification and as directed by the departmental officers. | |||||
| 6Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) | |||||
| 6.01 | In Ground floor | - | m2 | - | - |
| 6.02 | In First floor | - | m2 | - | - |
| 7Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. | |||||
| 7.01 | In Foundation and Basement | - | m3 | - | - |
stage.html
html • 0.04 MB
techsummary_811837.pdf
finsummary_811837.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
BOQ_811837.xls
BOQ • 0.32 MB
Mayiladuthuraielectionworkcondition.pdf
Tender Documents • 1.69 MB
Download all tender documents and submit your bid