Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder found in Order | |
| 2 | L2₹29.5 L+₹3.5 L (13.3%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹29.9 L+₹3.8 L (14.8%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹30.0 L+₹3.9 L (15.2%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹30.8 L+₹4.8 L (18.4%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹63,360
Closing Date
31 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS
Kupwara PIN 193 222
PRON OF RAIN WATER HARVESTING AND OTHER WORKS UNDER THE AOR OF GE 874 EWS
2025_MES_706800_1
GE 874/EWS-25/2025-26
Open Tender
Civil Works
Works
90 days
Kupwara
As per NIT
6 documents required · 6 mandatory
₹500
GE 874 EWS
₹63,360
Yes
31 Jul 2025
5 May 2025
2 Jun 2025
5 May 2025
31 May 2025
19 May 2025
Amount
M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil Complete all as specified and directed.
M&L Cement concrete 1:4:8 Type D2 (40mm Graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L brickwork with old size sub class B bricks, straight or curved on plan exc 6m mean radius, built in CM 1;6 with old size bricks complete all as specified and directed.
M&L returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
M&L for removing excavated material/soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, of any description including necessary scaffolding etc complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:4 is to be finished even and smooth with water proofing compound (without using extra lime or cement) including necessary scaffolding complete all as specified and directed.
Supply only Integral water proofing compound.
M&L for preparing new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 connecting plates complete all as specified and directed .
M&L for mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood/steel trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for preparing new surfaces of steel of any description, over 10cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer Complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa at roof level, formed in a shape of rain water channel, shape and size as directed by Engineer in charge fixed with self tapping screws complete all as specified and directed.
M&L for loose filling with Broken stone aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and directed.
M&L for PVC under ground tank of 5000 ltr capacity including providing PCC (1:3:6) type C-2,150 mm thick in foundation, excavation, returning filling & removing surplus soil from outside of MOD land complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for cement concrete type B-2, 1:2:4 (40mm graded aggregate) in surface channels and drains complete all as specified and directed
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
S&F PVC (SWR) pipes110mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) bend 110mm dia any radius complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core 25 sqmm cross sectional area in trenches or walls complete all as specified and as directed.
M&L for sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified. Note: Punned thickness 18 CM shall be measured and paid.
Material and labour for kiln burnt Sub class 'B' bricks laid dry, flat, width wise along the length of cable in trenches after sand cushioning for protection of underground cable complete all as specified and directed.
Supply, install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15 mm thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synthetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following :-
Aluminium BUSBAR rating -200 Amps, cable entry (incoming and outgoing) form bottom with cable gland
Incoming: (a) MCCB 4 pole 63 Amps 16 kA - 01 No (Incoming)
Outgoing :-
(b) MCB TPN/Isolator TP 40 Amps 16 kA - 03 Nos (1 spare )
(e) LED indicating lamps -03 Nos
Supply, Installation, testing and commissioning of centrifugal pump set 5HP with bronze impeller having minimum discharge of 120 LPM at head 30 mtr coupled with suitable capacity of electric motor 415 volts 3 phase 50Hz having 2900 RPM Monoblock and Having power not less than 2 HP, fixed on MS channel 100mm duly grouted with suitable size of nuts and bolts in PCC foundation and starter as per manufacturers recommendation including material and labour for making electric connection with suitable size of three core stranded XLPE cable through laid in cable duct /trenches/pole from starter to electric motor of pumping set and necessary water supply connection for suction and delivery side of pump set with suitable size of medium grade GI pipe complete upto NRV all as specified and directed.
Supply and fixing in replacement foot valve of size 50 mm complete all as specified and directed.
S&F non-return valve heavy duty of size 50 mm bore, ISI Marked, flanged ends including suitable nut bolts, washers, packing sheet, etc complete with necessary arrangements for fixing complete all as specified and directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm dia complete all as specified and directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm dia complete all as specified and directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm dia complete all as specified and directed.
S&F valve stop valve GM gate screwed complete for size 50 mm complete all as specified and directed.
S&F valve stop valve GM gate screwed complete for size 25 mm complete all as specified and directed.
S&F valve stop valve GM gate screwed complete for size 20 mm complete all as specified and directed.
M&L for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed
M&L for cement concrete 1:2:4 Type D2 (40mm Graded aggregate) in foundations, filling and mass concrete Complete all as specified and directed.
M&L for mild steel rolled sections as in main and cross beams, columns, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
M&L for 3mm thick aluminium composite panel (ACP panel) in ceiling cladding plain of approved colour/shape to Beam /column/slab in circular/rectangular shape including all offsets, bending and clits wherever required to give the required shape and design and silicon filling the joints using waterproofing sealant including suspension wire wherever required using and fabricating aluminium tubular hollow section 25mmx25mm frame work of size not exceeding 900mm c/c on existing pipes/purlin/Rafter/column to hold ACP cladding etc Complete all as specified and directed.
S&F writing letters or figures (Block, Roman, italic or Indian) n. exc. 45 CM high in brass or CP brass metallic complete all as specified and directed.
Dismantling and taking out unserviceable steel tubing and connections, bore of pipes 40/50 mm.
Dismantling and taking out unserviceable MS ERW column pipe 50 mm dia 50 mm bore in 3 mtr length both end flanged complete all as specified and directed.
Supply and laying steel water tubing of 50 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc are laid in trenches, complete all as specified and directed.
Supply and fixing 50 mm gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe suitable for 50 mm dia pipe complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finishing surface 10 cm from top using cement concrete1:3:6, type C-0 including removal of surplus soil complete all as specified and directed.
Supply and lowering in borewell, MS ERW column pipe 50 mm (2”) dia/50 mm bore in 3 mtr length both end flanged with MS flanges 10 mm thick with cut for passing the submersible cable and four no. of holes 10 mm dia with suitable size of nuts, bolts, washers, and rubber gasket complete all as specified and directed. Note: All arrangement & T&P required for lowering the column pipe in the bore shall be made by the contractor under their own arrangement at no extra cost complete all as specified and directed.
Supply and fix Submersible pump Starter for 7.5/10 HP Motor complete all as specified and directed.
Material and labour for rewinding of submersible motor up to 7.5/10 HP by taking out the burnt out winding from the starter with PVC insulated copper winding wire of same gauge and size as per existing, replacement of thrust bearing and bushes and testing complete all as specified and directed.
Supply, laying/ fixing cable for flat submersible with stranded copper conductor 3 core 1100 volts grade 6 Sqmm cross sectional area confirming to relevant IS complete all as specified and directed.
Supply and installation of air cooled spilt unit air conditioner electric driven single phase of cooling and heating type split Acs capacity of 1.5 TR, BEE 5 tar rated complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
Concept Engineering & Constructions (BID ID -3304576)
M/S MUNEER AHMAD WANI CONSTRUCTIONS (BID ID -3310040)
MS RJ BUILDERS (BID ID -3310015)
M/S SAJAA CONSTRUCTION COMAPNY (BID ID -3300157)
M/S BASHIR AND SONS (BID ID -3310233)
Bidder Name
M/S BASHIR AND SONS
M/S SAJAA CONSTRUCTION COMAPNY
M/s Pall Constructions
Concept Engineering & Constructions
M/S MUNEER AHMAD WANI CONSTRUCTIONS
MS RJ BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .