| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.5 L+₹4.5 L (12.0%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹46.8 L+₹9.8 L (26.4%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹49.2 L+₹12.1 L (32.8%)Rejected-Finance THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L4 | Rejected-Finance Not Being L1 |
Tender Value
₹38.3 L
EMD Value
₹76,600
Closing Date
10 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE No 2 Secunderabad
CWE No 2 Secunderabad, Mudfort, MES Complex, Secunderabad-500003
PROVN OF 100 KVA POWER SUPPLY AT NSF NODE AT GE BELGAUM
2022_MES_527575_2
81087/E8
Open Tender
Civil Works
Item Rate
180 days
GE Belgaum
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Belgaum
₹76,600
Yes
17 Sept 2022
20 Aug 2022
13 Sept 2022
20 Aug 2022
10 Sept 2022
27 Aug 2022
Amount
Supply, errect, install , testing and commissioning of outdoor non walk in type, 11KV / 433 V 100 KVA Compact Substation (CSS), as per IEC 62271-202 type, including necessary foundation and platform of required size and specifications all as per manufacturers instructions complete consisting of the following all as specified and as directed. (a) 100 KVA transformer (b) HT Switchgears (c) LVS Panel (d) APFC panel (e) Outdoor enclosure with slant roof Make : ABB/ Schnieder/ Siemens/Areva . Note : 1. The degree of Protection for HT & LT shall be IP-54. 2. The CSS shall be confirmirng to IEC-6227-100, IEC-62271-200, 62271-103 & 62271-201 and as per latest IS codal provisions. 3. Schematic Digaram and makes shall be approved by GE before placing order with the manufacturer. 4. Makes of all components and switch gares shall be as per OEM recommendations.
Supply, laying & testing XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric cable (Heavy Duty) with stranded aluminium conductor, 11000 volts grade, cross-sectional area 95 sq. mm x 3 core all as specified as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core all as specified as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm all as specified as directed.
Supply and fix Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sq mm all as specified as directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified as directed.
S & F GI tube medium grade 80 mm bore laid as fixed in trenches / road / drain / wall complete all as specified and directed with MS clamp and nut bolts and washers etc, all as specified and as directed.
M&L for earthing with Copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level. The earth plate to be connected with copper earthing strip of size 20 mm x 3 mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing only, earth strip protected by GI light grade pipe 40 mm bore, 20mm dia medium grade galvanised iron watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling complete and connecting to main switch board / control board all s shown in electrical plate of SSR Part - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate also include for making of earth test point, excavation, earth work in hard/dense soil, plain cement concrete 1:2:4 type C1 by using 20 mm graded aggregate in pit, 75 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 6 mm dia TMT bars @ 75mm centre to centre both ways with 12mm dia MS bar handle made to shape, GI pipe & copper earth lead upto 7.50m length, wire mesh, salt, charcoal complete.
M&L for earthing with galvanized mild steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized steel strip of 32 x6 mm size by means of bolts, nuts and washers made out of GI / steel, earth wire protected by GI light grade pipe 40 mm bore, 20mm dia medium grade galvanised iron watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling complete and connecting to main switch board / control board all s shown in electrical plate of SSR Part - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate also include for making of earth test point, excavation, earth work in hard/dense soil, plain cement concrete 1:2:4 type C1 by using 20 mm graded aggregate in pit, 75 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 6 mm dia TMT bars @ 75mm centre to centre both ways with 12mm dia MS bar handle made to shape, GI pipe & GI earth strip upto 7.50m length, wire mesh, salt, charcoal complete.
Fabricating, supplying, installing, testing and commissioning of LT Feeder Pillar Box, outdoor type, factory made from CPRI approved manufacturer with IP 55 protection, 415 volts , 50Hz, 3 phase, 4 wire system, made out of 3 mm thick CRCA sheet, totally enclosed, weather, vermin and dust proof, both sides operated with inner shutter and outer double door with locking arrangement and ventilator slots, cable trays, incoming/ outgoing cable glands, thimbles, lugs, etc. of suitable size, danger board, etc. and painting with epoxy powder coated over a coat of red oxide zinc chromate primer suitable to accommodate and including the following mentioned fittings with internal copper wiring complete including 50x50x5mm size MS angle frame fixed 300mm above GL and 450mm below GL duly grouted in and including PCC foundation 1:3:6 type C1 of suitale size and depth including taking down existing feeder pillar box of any description capacity and type and re-fixing the existing cables to new panel all as specified and as directed.
(a) Aluminium bus bar of 400 Amps rating for 3 phase & 200 Amps rating for neutral - 1 Set (b) Digital MCCB 4 pole 415 Volts 25 KA 200 Amps - 01 No. (Incoming) (c) MCCB 4 pole 415 Volts 16 KA 125 Amps - 02 Nos. (Outgoing), One No Spare (d) MCCB 4 pole 415 Volts 16 KA 100 Amps - 02 Nos. (Outgoing), One No Spare (e) LED Indicating lamps indicating R, Y, B -01 Set (f) Digital Multifunction meter for reading volts, ampere, frequency, energy, PF with CTs & PTs- 01 Set (g) Long range integrated meter 3 phase thread through 40-200A DLMS type integrated CT meter with inbuilt model of Make L&T.
Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in any type of soil complete all as specified and as directed.
Returing, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed.
Removing excavated materials not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Material and Labour for unreinforced precast concrete cable covers class HV Type 1 flat size 300x180x40 mm all as per specified and as directed.
Material and Labour for unreinforced precast concrete cable covers class LV Type 1 flat size 250x150x40 mm all as per specified and as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet, viterous enamelled white with letters, figures & conventional skulls & bones in signal red colour & fixed with MS clamps, bolts & nuts of approved size for HT, 25x20 cm size all as specified and as directed.
Material and Labour for dry river sand spread in trenches as in cable cushioning complete all as specified and as directed. Note :- Punned thickness only shall be considerd for payment
E M CONSTROL SYSTEM
ASHIRWAD ELECTRICALS
Green Ray Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .