Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹2.6 L+₹48,198 (22.7%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹3.3 L+₹1.1 L (53.5%)Rejected-Finance WATHORA CHADOORA BUDGAM KASHMIR J K 191113 | CHADOORA | BUDGAM | JAMMU AND KASHMIR | 191113 | L3 | Rejected-Finance Other Than L1 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
7 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR / MAINT OF MANZIRA WATER SUPPLY LINE AND CONNECTED WORKS AT HQ CIF (K) UNDER AGE(I) CIF(K)
2022_MES_523180_1
CA NO. AGE (I) CIF (K)- 25/2022-23
Open Tender
Civil Works - Water Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹300
AGE (I) CIF (K)
₹10,000
Yes
11 Jun 2022
10 May 2022
9 Jun 2022
10 May 2022
7 Jun 2022
24 May 2022
60 days
Amount
Taking up or down GI water tubing and connections of 20 mm bore, including cleaning for re-fixing or removal from site for the following sizes (bore of pipe), complete all as specified and as directed by the Enginee-in- Charge. Note :- Earth work shall be measured and paid under respective item of BOQ.
Description all as per serial item No 01 here-in-before, but 50 mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 01 here-in-before, but 100mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Steel water tubing of nominal bore 20 mm, medium grade galvanised ISI marked as per IS:1239 Part-I with all fittings including short lengths, fixed to walls/roof, concealed in wall and ceiling or laid in trenches/floors complete with all fittings ( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by the Enginee-in- Charge.
Description all as per serial item No 04 here-in-before, but 50mm bore, complete all as specified and as directed by the Enginee-in- Charge.
Steel water tubing of nominal bore 80 mm, medium grade galvanised ISI marked as per IS:1239 Part-I with all fittings including short lengths, fixed to walls/roof, concealed in wall and ceiling or laid in trenches/floors complete with all fittings ( such as flanges 3 inch dia (Welded with pipe),rubber washer,nut bolt etc. complete which ever is to be required at site ) complete all as specified and as directed by the Enginee-in- Charge.
Gun metal globe or gate valve with iron wheel head screwed both ends (ISI marked) for iron pipes and fixed of size 20mm bore dia, including taking down old unserviceable, complete all as specified and as directed by the Engineer-in-Charge.
Gun metal globe or gate valve with iron wheel head screwed both ends (ISI marked) for iron pipes and fixed of size 50mm bore dia, including taking down old unserviceable, complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate, as in foundation filling and mass concrete, road cuttings etc., complete all as specified and asdirected by the Engineer-in-Charge.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc., or for shafts, wells, cesspits, manholes, laying pipes CI/GI etc., not exceeding 10 Sqm on plan and n. exc. 1.5 metre in depth and getting out, in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading , leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and as directed by the Engineer-in-Charge.
Cutting existing steel tubing 40mm or 50mm bore for alterations or additions, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement of CI Sluice valves PN 1.6 flanged and of sizes for 80mm bore complete with iron wheel head and spindle including material and labour for flanged joints and replacement of nuts and washers etc., complete all as specified and as directed by the Engineer-in-Charge.
Collecting water sample from pump house/ RO plant and submitted water sample for testing at water testing lab zainakote srinagar ,After complete testing submit testing report to AGE (I) CIF (K), complete all as directed by the Engineer-in-Charge.
Brick masonry valve chamber of size 0.60m x 0.6m x 0.6m internal dimension suitable for sluice valve, with 100mm thick PCC (1:3:6) type C-2 for foundation, one brick wall in cement mortar (1:6), 40mm thick PCC (1:2:4) type B-1 for coping, rendering in cement mortar (1:4) 15mm thick internally and externally flush pointed in same mortar as the work proceeds. Flooring shall be 40mm thick in PCC 1:2:4 type B-1 laid over 75mm thick hard core including provision of mild steel sheet cover 3.15mm thick on 40mm x 40 x 6mm angle iron frame work with two coat of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation, earth work and demolishing the damaged valve chamber and removing debris, complete all as specified and directed at site by the Engineer-in- Charge.
Description all as per Serial item No 16 here-in-before, but size of chamber 0.90m x 0.90m x 0.90m, complete all as specified and directed at site by the Engineer-in- Charge.
Note :- An amount of Rs. 53,115.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S SHEIKH FEROOZ AHMAD
M/S BHAT AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .