Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.7 LQualified Make: Dell
Model: PowerEdge R430 2-socket Rack Server (Dell) 1 TULSI NIKETAN HIRAN MAGRI SECTOR 4 UDAIPUR 1 TULSI NIKETAN HIRAN MAGRI SECTOR 4 UDAIPUR 1 TULSI NIKETAN HIRAN MAGRI SECTOR 4 UDAIPUR UDAIPUR | Make: Dell
Model: PowerEdge R430 2-socket Rack Server (Dell) | L1 | Qualified | |
| 2 | L2₹2.8 L+₹14,980 (5.55%)Qualified Make: HPE
Model: HPE DL380 Gen9 1059 42 KALKAJI DDA FLATS NEW DELHI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: HPE
Model: HPE DL380 Gen9 | L2 | Qualified | |
| 3 | L3₹3.0 L+₹29,999 (11.1%)Qualified Make: Hewlett Packard Enterprise
Model: HPE Proliant DL180 Gen9 Server C 115 UPPER GROUND FLOOR MOHAN GARDEN UTTAM NAGAR DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | Make: Hewlett Packard Enterprise
Model: HPE Proliant DL180 Gen9 Server | L3 | Qualified | |
| 4 | Disqualified Make: hp
Model: HP PROLIANT ML350 GEN 10-3106 Xeon 8C/4LFF 121 RANI DURGAWATI WARD NO 34 H S S SCHOOL SHOBHAPUR BETUL MADHYA PRADESH 460449 | BETUL | MADHYA PRADESH | 460449 | Make: hp
Model: HP PROLIANT ML350 GEN 10-3106 Xeon 8C/4LFF | - | Disqualified | |
| 5 | Disqualified Make: Dell
Model: Dell poweredge R530 0 | Make: Dell
Model: Dell poweredge R530 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
22 Oct 2018, 9:00 amClosed
computer servers Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 1 Year (s) Computer Servers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack
Tower Size (RU) 2 * Processor Make Intel Intel
AMD
SPARC
IBM Power Max. Number of sockets available on chipset 2 1-16 Max. Number of sockets populated with processor 2 1-16 Number of core per Processor 8 * Processor Configuration E5-2620 v4
8 core
2.10 GHz with 20 MB smart cache memory
85 watt * Chipset compatible C600 * 1/4 with CPU Availability of Co- Processor No * If Yes Co-Processor Configuration NA * PCI Slots (Express Gen 3.0) 6 * Type of RAM DDR4 * RAM Size (GB) 32 16-16000 RAM upgradable upto (GB) 512 32-24000 DIMM Slots (No.) 16 * Type of Hard Disk Drive SAS SAS
NL SAS
SSD
SATA Hard disk drive Capacity (GB) 2700 300-12000 Hard disk drive Speed (RPM) 10K * RAID Controller Cache (MB) 512 * RAID Type 1 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard Yes * Mouse Yes * Bays (min. 2 internal or more hot plug) 8 * USB Ports (version 2.0/3.0) 5 * Certifications Compliance support by Windows
Red Hat or Novell or Oracle Cluster or Linux or AIX S/W Yes * DVD ROM (or better) 8x or better * Network Card Supported 1G * FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * 2/4 Redundant Power Supply Yes * Redundant Fan Yes * Total No of Ports 6 * Declare SPEC int_rate_base 2006 ; specfp_rate_2006 for 1
2
4
8 prcessor as applicable na * Server scalability to be achieved within the box without adding nodes NA * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 450 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional No * Name address of Lab - * 3/4 Test Report No. date - * Power Supply 230 V +/-10%
50 Hz * On Site OEM Warranty (years) 3 1
3
5 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indranil Mukherjee 721145
AIR FORCE STATION SALUA 1 30
715065
GEM/2018/B/100991
computer servers
30 days
West Bengal; Medinipur West
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| computer servers Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 1 Year (s) Computer Servers ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack | - | - | - |
| Tower Size (RU) 2 * Processor Make Intel Intel | - | - | - |
| AMD | - | - | - |
| SPARC | - | - | - |
| IBM Power Max. Number of sockets available on chipset 2 1-16 Max. Number of sockets populated with processor 2 1-16 Number of core per Processor 8 * Processor Configuration E5-2620 v4 | - | - | - |
| 8 core | - | - | - |
| 2.10 GHz with 20 MB smart cache memory | - | - | - |
| 85 watt * Chipset compatible C600 * 1/4 with CPU Availability of Co- Processor No * If Yes Co-Processor Configuration NA * PCI Slots (Express Gen 3.0) 6 * Type of RAM DDR4 * RAM Size (GB) 32 16-16000 RAM upgradable upto (GB) 512 32-24000 DIMM Slots (No.) 16 * Type of Hard Disk Drive SAS SAS | - | - | - |
| NL SAS | - | - | - |
| SSD | - | - | - |
| SATA Hard disk drive Capacity (GB) 2700 300-12000 Hard disk drive Speed (RPM) 10K * RAID Controller Cache (MB) 512 * RAID Type 1 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard Yes * Mouse Yes * Bays (min. 2 internal or more hot plug) 8 * USB Ports (version 2.0/3.0) 5 * Certifications Compliance support by Windows | - | - | - |
| Red Hat or Novell or Oracle Cluster or Linux or AIX S/W Yes * DVD ROM (or better) 8x or better * Network Card Supported 1G * FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * 2/4 Redundant Power Supply Yes * Redundant Fan Yes * Total No of Ports 6 * Declare SPEC int_rate_base 2006 ; specfp_rate_2006 for 1 | - | - | - |
| 2 | - | - | - |
| 4 | - | - | - |
| 8 prcessor as applicable na * Server scalability to be achieved within the box without adding nodes NA * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 450 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning | - | - | - |
| After completion of the above environmental tests sequence | - | - | - |
| with a recovery period of 1 to 2 hrs | - | - | - |
| the server shall be functional No * Name address of Lab - * 3/4 Test Report No. date - * Power Supply 230 V +/-10% | - | - | - |
| 50 Hz * On Site OEM Warranty (years) 3 1 | - | - | - |
| 3 | - | - | - |
| 5 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indranil Mukherjee 721145 | - | - | - |
| AIR FORCE STATION SALUA 1 30 | - | - | - |
Exempted
22 Oct 2018
9 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_715065.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .