Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.7 LAccepted-Finance 40 JAGAJEEVANRAM STREET MINJUR 601 203 | MINJUR | THIRUVALLUR | TAMIL NADU | 601203 | L1 | Accepted-Finance accepted | |
| 2 | L2₹54.0 L+₹2.3 L (4.54%)Accepted-Finance NO 03 PERUMAL KOVIL STREET MINJUR 601203 | THIRUVALLUR | TAMIL NADU | 601203 | L2 | Accepted-Finance accepted |
| Sl No | Description | Qty | Unit | M.ANBAZHAGAN L2 | GOWTHAM ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for removal of the local Pressure/Temperature Gauges and refixing them after calibration in Boiler, Turbine & Generator areas. | 216 | Nos | 576 ₹1,46,810.88 | 551 ₹1,40,438.88 Lowest |
| 2.00 | Charges for Removal of Pressure/Temperature/ Vacuum / flow SWITCHES and refixing them after calibration in Boiler,Turbine and Generator areas . | 204 | Nos | 576 ₹1,38,654.72 | 551 ₹1,32,636.72 Lowest |
| 3.00 | Charges for removing from field, transporting to lab, cleaning, handing over to lab for calibration, and re fixing after calibration of AIR REGULATOR with gauges. | 210 | Nos | 576 ₹1,42,732.8 | 551 ₹1,36,537.8 Lowest |
| 4.00 | Fixing the keltron pneumatic actuator in the new bed bolt assembly and refixing the accessories such as Air regulator, I/P converter with SS tubings and making alignment for the same. | 172 | Nos | 8,855 ₹17,97,210.8 | 8,470 ₹17,19,071.2 Lowest |
| 5.00 | Charges for releasing of Electronic cards from the racks, cleaning of panels & reinserting the cards, terminal tightness checking of FSSS, SADC, PRDS, Feeder, HYDRASTEP, 110 V
AC & 220 V DC distribution panels and CHARGER Panels. | 180 | panels | 1,183 ₹2,51,269.2 | 1,132 ₹2,40,436.8 Lowest |
| 6.00 | Removing, cleaning, transporting to work bench, servicing, air leak and operation checking, re fixing and checking of Retractor Assembly of HEA/IFM Ignitors. | 72 | Nos | 3,982 ₹3,38,310.72 | 3,808 ₹3,23,527.68 Lowest |
| 7.00 | Disconnecting the connectors of the flame scanners, removing from the Boiler guide pipe assembly, transporting to work bench,dismantling & Reassembling the scanner head assembly from scanners, removing, cleaning & refixing the lenses, servicing and checking of flame scanners. | 360 | Nos | 1,493 ₹6,34,226.4 | 1,428 ₹6,06,614.4 Lowest |
| 8.00 | Removing, cleaning, servicing, refixing and checking of SADC positioners. | 396 | Nos | 1,176 ₹5,49,521.28 | 1,125 ₹5,25,690 Lowest |
| 9.00 | Charges for removing, cleaning solenoid valves, air filter cum lubricator & the air lines and replacing the ‘O’ rings in the solenoid valves and refixing the solenoid valves, air filter cum
lubricator & the air lines in the HAGs. | 97 | Nos | 2,827 ₹3,23,578.42 | 2,704 ₹3,09,499.84 Lowest |
| 10.00 | Charges for Dismantling, cleaning and refixing of limit switches, including disconnecting and reconnecting the power cables, removal of clamps, cleaning of switch contacts. | 186 | Nos | 281 ₹61,673.88 | 269 ₹59,040.12 Lowest |
Tender Value
Refer Docs
EMD Value
₹44,600
Closing Date
11 Sept 2026, 2:00 pmClosed
SE/ES
SE/ES NCTPS-I Ch-120.
NCTPS I ES Circle C I Division S Dn IV FSSS Execution of Maintenance activities for C I Equipment associated with FSSS SADC and allied areas of Units I II III for a period of 360 Days for the year 2026 27
2026_EB_699387_1
CE/NCTPS-I/SE/ES/WC-36/2026-27
Open Tender
Power/Energy Projects/Products
Works
360 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹44,600
Yes
28 Sept 2026
29 Aug 2026
15 Sept 2026
29 Aug 2026
11 Sept 2026
29 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for removal of the local Pressure/Temperature Gauges and refixing them after calibration in Boiler, Turbine & Generator areas. | 216 | Nos | 500.66 | ₹1,08,142.56 |
| 2 | Charges for Removal of Pressure/Temperature/ Vacuum / flow SWITCHES and refixing them after calibration in Boiler,Turbine and Generator areas . | 204 | Nos | 500.66 | ₹1,02,134.64 |
| 3 | Charges for removing from field, transporting to lab, cleaning, handing over to lab for calibration, and re fixing after calibration of AIR REGULATOR with gauges. | 210 | Nos | 500.66 | ₹1,05,138.6 |
| 4 | Fixing the keltron pneumatic actuator in the new bed bolt assembly and refixing the accessories such as Air regulator, I/P converter with SS tubings and making alignment for the same. | 172 | Nos | 7,700 | ₹13,24,400 |
| 5 | Charges for releasing of Electronic cards from the racks, cleaning of panels & reinserting the cards, terminal tightness checking of FSSS, SADC, PRDS, Feeder, HYDRASTEP, 110 V
AC & 220 V DC distribution panels and CHARGER Panels. | 180 | panels | 1,028.87 | ₹1,85,196.6 |
| 6 | Removing, cleaning, transporting to work bench, servicing, air leak and operation checking, re fixing and checking of Retractor Assembly of HEA/IFM Ignitors. | 72 | Nos | 3,462.62 | ₹2,49,308.64 |
| 7 | Disconnecting the connectors of the flame scanners, removing from the Boiler guide pipe assembly, transporting to work bench,dismantling & Reassembling the scanner head assembly from scanners, removing, cleaning & refixing the lenses, servicing and checking of flame scanners. | 360 | Nos | 1,298.48 | ₹4,67,452.8 |
| 8 | Removing, cleaning, servicing, refixing and checking of SADC positioners. | 396 | Nos | 1,023.05 | ₹4,05,127.8 |
| 9 | Charges for removing, cleaning solenoid valves, air filter cum lubricator & the air lines and replacing the ‘O’ rings in the solenoid valves and refixing the solenoid valves, air filter cum
lubricator & the air lines in the HAGs. | 97 | Nos | 2,458.5 | ₹2,38,474.5 |
| 10 | Charges for Dismantling, cleaning and refixing of limit switches, including disconnecting and reconnecting the power cables, removal of clamps, cleaning of switch contacts. | 186 | Nos | 244.31 | ₹45,441.66 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_840793.xls
BOQ • 0.35 MB
corrigendum.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .